Related papers: Beam instrumentation for the Tevatron Collider
Muon identification is of paramount importance for the physics programme of LHCb. In the upgrade phase, starting from Run 3 of the LHC, the trigger of the experiment will be solely based on software. The luminosity increase to…
The B physics program planned for the D0 Upgrade Detector for Run 2 of the Tevatron is described. Current performance of the detector pertinent to B physics is presented and compared to expectations. Detection of b hadrons through…
The Large Hadron Collider is currently undergoing its High Luminosity upgrade, which is set to increase the instantaneous luminosity by about a factor of five. Consequently, the Compact Muon Solenoid experiment is upgrading its muon…
The T-980 bent crystal collimation experiment at the Tevatron has recently acquired substantial enhancements. First, two new crystals - a 16-strip one manufactured and characterized by the INFN Ferrara group and a quasi-mosaic crystal…
The LIDAR Thomson scattering concept was proposed in 1983 and then implemented for the first time on the JET tokamak in 1987. A number of modifications were performed and published in 1995, but since then no major changes were made for…
The LHCb detector optimised its performance in Runs~1 and~2 by stabilising the instantaneous luminosity during a fill. This was achieved by tuning the distance between the two colliding beams according to the measurement of instantaneous…
We discuss possibilities of detecting neutral and charged long-lived particles with the upgraded D0 detector in Run II of the Fermilab Tevatron accelerator, using photon pointing, dE/dx, and time-of-flight techniques. Such particles appear…
We present an overview of the muon reconstruction and identification methods employed by the D0 Collaboration to analyze the Run II (2001-2011) ppbar data of the Fermilab Tevatron collider at sqrt s = 1.96 TeV. We discuss the performance of…
Magnetically confined hollow electron beams for controlled halo removal in high-energy colliders such as the Tevatron or the LHC may extend traditional collimation systems beyond the intensity limits imposed by tolerable material damage.…
We present recent results on b-hadron lifetimes and mixing obtained from the analysis of the data collected at the Tevatron Collider by the CDF and D0 Collaborations in the period 2002 - 2004. Many lifetime measurements have been updated…
The intensity of charged particle beams at Fermilab must be kept within pre-determined safety and operational envelopes in part by assuring all beam within a few percent has been transported from any source to destination. Beam intensity…
The CMS experiment at the LHC has started data taking in Run 3 at a $\mathrm{pp}$ collision energy of $13.6~\mathrm{TeV}$. In preparation for Run 3, detector systems, such as Pixel Tracker, HCAL and CSC, have been upgraded due to…
We present results on hard diffraction obtained by the CDF Collaboration in Run II proton-antiproton collisions at the Fermilab Tevatron. Run I CDF results on hard diffraction are also reviewed.
Beam-beam simulations predict that PEP-II luminosity can be increased by operating the horizontal betatron tune near and above a half-integer resonance. However, effects of the resonance and its synchrotron sidebands significantly enhance…
We first introduce the design parameters of the Beijing Electron-Positron Collider II (BEPCII) and the simulation study of beam-beam effects during the design process of the machine. The main advances since 2007 are briefly introduced and…
The future e-e+ 500 GeV International Linear Collider will rely on unprecedented nanometer scale particle beam size at the interaction point, in order to achieve the design luminosity. Tight tolerances on static and dynamic alignment of the…
A second major LHCb detector upgrade will be installed during long shutdown 4 (LS4) of the CERN Large Hadron Collider. The new detector will provide excellent performance for studies of Quantum Chromodynamics at high temperature and…
We present the strategy which has been used recently to optimize integrated luminosity at the Fermilab Tevatron proton-antiproton collider. We use a relatively simple model where we keep the proton intensity fixed, use parameters from fits…
The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton back-scattered photons. Many advanced techniques and precise…
The determination of beam parameters is essential for the operation and development of any accelerator facility. The working principle of frequently used beam instruments for electron and proton beams is discussed. The article comprises of…