Related papers: Beam instrumentation for the Tevatron Collider
In order to fully exploit the physics potential of the Tevatron Run 2, the D0 detector has been upgraded. Having nearly completed the commissioning phase, the D0 detector is starting to produce its first physics results. An overview of the…
Results on diffraction obtained by the CDF Collaboration in Run I of the Fermilab Tevatron $\bar pp$ collider are reviewed. New results are reported on soft double diffraction and diffractive $J/\psi$ production. The CDF program for…
The D0 experiment enjoyed a very successful data-collection run at the Fermilab Tevatron collider between 1992 and 1996. Since then, the detector has been upgraded to take advantage of improvements to the Tevatron and to enhance its physics…
The Fast Bunch Integrator is a bunch intensity monitor designed around the measurements made from Resistive Wall Current Monitors. During the Run II period these were used in both Tevatron and Main Injector for single and multiple bunch…
Particle accelerators for high energy physics will generate TeV-scale particle beams in large, multi-Km size machines colliding high brightness beams at the interaction point [1-4]. The high luminosity in such machines is achieved by…
A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in…
One of the main goals for hadron colliders is the study of the properties of the third generation quarks. We study the signatures for new TeV resonances that couple to top or bottom quarks both at the Tevatron Run II and at the LHC. We find…
This paper discusses supersymmetry discovery potential of the upgraded D\O experiment at the Tevatron $p\bar{p}$ collider. Six final states with large transverse energy (momentum) leptons or photons (with or without large transverse…
Electroweak measurements from early in Run II of the Tevatron Collider at Fermilab are presented as well as future prospects for Run II. The effect of Tevatron measurements on worldwide electroweak fits and the Higgs mass is also discussed.
For 25 years the Tevatron proton-antiproton collider was the highest energy collider in the world. This presentation will trace the origins of the Tevatron, the challenges that were overcome in creating high luminosity collisions of protons…
We outline several improvements to the experimental analyses carried out at Tevatron (Run 2) or simulated in view of the Large Hadron Collider (LHC) that could increase the scope of CDF/D0 and ATLAS/CMS in detecting charged Higgs bosons
In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from $4\times 10^{32}\rm{cm}^{-2}\rm{s}^{-1}$ to $2\times 10^{33}\rm{cm}^{-2}\rm{s}^{-1}$. Several hardware…
We present a comprehensive review of the physics results obtained by the CDF and D0 collaborations up to summer 2014, with emphasis on those achieved in the Run II of the Tevatron collider which delivered a total integrated luminosity of…
Since the end of Run 1 of the LHC in 2012, the outermost ring has been added to the CMS Cathode Strip Chambers (CSC) endcap muon detector, and the readout electronics of the innermost ring of CSCs have been upgraded to accommodate the…
Collimation systems are essential in particle accelerators to safely and efficiently manage unavoidable beam losses during operation. These systems rely on collimators, which are specially designed movable jaws or absorbers positioned close…
In the next decade, intensity frontier experiments will require tracking systems that are robust against high event and background rates while maintaining excellent tracking performance. We develop a first conceptual design of a tracking…
The CDF experiment is successfully collecting data from ppbar collisions at the Tevatron in Run II. As the data samples are getting larger, systematic uncertainties due to the measurement of the jet energy scale assessed using the…
In this contribution, a comprehensive review of the main aspects of high pt jet physics in Run II at the Tevatron is presented. Recent measurements on inclusive jet and dijet production are discussed using different jet algorithms and…
The D0 Detector at Fermilab is currently undergoing an extensive upgrade to participate in the Run II data taking which shall begin on March 1, 2001. The design of the detector meets the requirements of the high luminosity environment…
In 1995 a 9SDH-2 Pelletron from NEC was installed at IFUNAM (Instituto de Fisica, Universidad Nacional Autonoma de Mexico). Two beam lines have been operational since then and two new lines have been built. In order to perform the planned…