Related papers: GPU-based Fast Low-dose Cone Beam CT Reconstructio…

200 papers

Cone Beam Computed Tomography(CBCT) is a now known method to conduct CT imaging. Especially, The Low Dose CT imaging is one of possible options to protect organs of patients when conducting CT imaging. Therefore Low Dose CT imaging can be…

Computer Vision and Pattern Recognition · Computer Science 2021-04-05 Wooram Kang , Mayank Patwari

Computed Tomography (CT) is an essential non-destructive three dimensional imaging modality used in medicine, security screening, and inspection of manufactured components. Typical CT data acquisition entails the collection of a thousand or…

Medical Physics · Physics 2024-10-11 Kyle M. Champley , Michael B. Zellner , Joseph W. Tringe , Harry E. Martz

The cone-beam computed tomography (CBCT) provides 3D volumetric imaging of a target with low radiation dose and cost compared with conventional computed tomography, and it is widely used in the detection of paranasal sinus disease. However,…

Image and Video Processing · Electrical Eng. & Systems 2022-11-30 Kyungsu Kim , Chae Yeon Lim , Joong Bo Shin , Myung Jin Chung , Yong Gi Jung

Cone-Beam Computed Tomography (CBCT) is widely used for real-time intraoperative imaging due to its low radiation dose and high acquisition speed. However, despite its high resolution, CBCT suffers from significant artifacts and thereby…

Image and Video Processing · Electrical Eng. & Systems 2025-06-11 Maximilian Tschuchnig , Lukas Lamminger , Philipp Steininger , Michael Gadermayr

During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides…

Computer Vision and Pattern Recognition · Computer Science 2022-01-20 Mareike Thies , Jan-Nico Zäch , Cong Gao , Russell Taylor , Nassir Navab , Andreas Maier , Mathias Unberath

Reconstructing dynamic, time-varying scenes with computed tomography (4D-CT) is a challenging and ill-posed problem common to industrial and medical settings. Existing 4D-CT reconstructions are designed for sparse sampling schemes that…

Image and Video Processing · Electrical Eng. & Systems 2021-04-26 Albert W. Reed , Hyojin Kim , Rushil Anirudh , K. Aditya Mohan , Kyle Champley , Jingu Kang , Suren Jayasuriya

Advancements in AI have greatly enhanced the medical imaging process, making it quicker to diagnose patients. However, very few have investigated the optimization of a multi-model system with hardware acceleration. As specialized edge…

Hardware Architecture · Computer Science 2025-10-03 Ashiyana Abdul Majeed , Mahmoud Meribout , Safa Mohammed Sali

Accurate dose calculations in proton therapy rely on high-quality CT images. While planning CTs (pCTs) serve as a reference for dosimetric planning, Cone Beam CT (CBCT) is used throughout Adaptive Radiotherapy (ART) to generate sCTs for…

Computer Vision and Pattern Recognition · Computer Science 2025-03-12 David Vallmanya Poch , Yorick Estievenart , Elnura Zhalieva , Sukanya Patra , Mohammad Yaqub , Souhaib Ben Taieb

This study proposes a novel imaging and reconstruction framework for dual-energy cone-beam CT (DECBCT) using only two orthogonal X-ray projections at different energy levels (2V-DECBCT). The goal is to enable fast and low-dose DE volumetric…

Medical Physics · Physics 2025-04-18 Junbo Peng , Tonghe Wang , Shaoyan Pan , Xiaofeng Yang

Computed Tomography (CT) reconstruction is a fundamental component to a wide variety of applications ranging from security, to healthcare. The classical techniques require measuring projections, called sinograms, from a full 180$^\circ$…

Computer Vision and Pattern Recognition · Computer Science 2018-07-12 Rushil Anirudh , Hyojin Kim , Jayaraman J. Thiagarajan , K. Aditya Mohan , Kyle Champley , Timo Bremer

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

Image and Video Processing · Electrical Eng. & Systems 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

Computed tomography from a low radiation dose (LDCT) is challenging due to high noise in the projection data. Popular approaches for LDCT image reconstruction are two-stage methods, typically consisting of the filtered backprojection (FBP)…

Image and Video Processing · Electrical Eng. & Systems 2025-03-17 Tim Selig , Thomas März , Martin Storath , Andreas Weinmann

Low-dose Computed Tomography is a common issue in reality. Current reduction, sparse sampling and limited-view scanning can all cause it. Between them, limited-view CT is general in the industry due to inevitable mechanical and physical…

Image and Video Processing · Electrical Eng. & Systems 2021-01-20 Ken Deng , Chang Sun , Yitong Liu , Hongwen Yang

A key step in Adaptive Radiation Therapy (ART) workflows is the evaluation of the patient's anatomy at treatment time to ensure the accuracy of the delivery. To this end, Cone Beam Computerized Tomography (CBCT) is widely used being…

Image and Video Processing · Electrical Eng. & Systems 2025-02-10 Ricardo Coimbra Brioso , Leonardo Crespi , Andrea Seghetto , Damiano Dei , Nicola Lambri , Pietro Mancosu , Marta Scorsetti , Daniele Loiacono

X-ray computed tomography (CT) reveals the materials' internal structures non-destructively from a tilt series of projected images. Filtered back projection (FBP) is a widely-adopted reconstruction algorithm in CT owing to its small…

Ptychography is a popular microscopic imaging modality for many scientific discoveries and sets the record for highest image resolution. Unfortunately, the high image resolution for ptychographic reconstruction requires significant amount…

Image and Video Processing · Electrical Eng. & Systems 2022-12-19 Xiao Wang , Aristeidis Tsaris , Debangshu Mukherjee , Mohamed Wahib , Peng Chen , Mark Oxley , Olga Ovchinnikova , Jacob Hinkle

Purpose: Optoacoustic tomography (OAT) is inherently a three-dimensional (3D) inverse problem. However, most studies of OAT image reconstruction still employ two-dimensional (2D) imaging models. One important reason is because 3D image…

Medical Physics · Physics 2013-04-09 Kun Wang , Chao Huang , Yu-Jiun Kao , Cheng-Ying Chou , Alexander A. Oraevsky , Mark A. Anastasio

Time-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection without phase sorting or binning), is highly desired for regular and irregular motion characterization,…

Medical Physics · Physics 2025-07-28 Jiacheng Xie , Hua-Chieh Shao , You Zhang

Boron Neutron Capture Therapy (BNCT) is an innovative binary form of radiation therapy with high selectivity towards cancer tissue based on the neutron capture reaction 10B(n,$\alpha$)7Li, consisting in the exposition of patients to neutron…

Cone-beam computed tomography (CBCT) is widely used in interventional surgeries and radiation oncology. Due to the limited size of flat-panel detectors, anatomical structures might be missing outside the limited field-of-view (FOV), which…