English
Related papers

Related papers: GPU-based Fast Low-dose Cone Beam CT Reconstructio…

200 papers

Cone-beam breast computed tomography (CT) provides true 3D breast images with isotropic resolution and high-contrast information, detecting calcifications as small as a few hundred microns and revealing subtle tissue differences. However,…

Medical Physics · Physics 2019-12-18 Wenxiang Cong , Hongming Shan , Xiaohua Zhang , Shaohua Liu , Ruola Ning , Ge Wang

Cone-beam computed tomography (CBCT) using only a few X-ray projection views enables faster scans with lower radiation dose, but the resulting severe under-sampling causes strong artifacts and poor spatial coverage. We address these…

Image and Video Processing · Electrical Eng. & Systems 2025-06-25 Minmin Yang , Huantao Ren , Senem Velipasalar

X-ray photon-counting computed tomography (PCCT) for extremity allows multi-energy high-resolution (HR) imaging but its radiation dose can be further improved. Despite the great potential of deep learning techniques, their application in HR…

Deep-neural-network-based image reconstruction has demonstrated promising performance in medical imaging for under-sampled and low-dose scenarios. However, it requires large amount of memory and extensive time for the training. It is…

Computer Vision and Pattern Recognition · Computer Science 2019-06-12 Dufan Wu , Kyungsang Kim , Quanzheng Li

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed and validated a method which uses these projections to…

Medical Physics · Physics 2015-01-15 Bernard L. Jones , David Westerly , Moyed Miften

Low-dose Proton Computed Tomography (pCT) is an evolving imaging modality that is used in proton therapy planning which addresses the range uncertainty problem. The goal of pCT is generating a 3D map of Relative Stopping Power (RSP)…

Cone Beam CT plays an important role in many medical fields nowadays, but the potential of this imaging modality is hampered by lower image quality compared to the conventional CT. A lot of recent research has been directed towards…

Medical Physics · Physics 2023-11-01 Nikita Moriakov , Jan-Jakob Sonke , Jonas Teuwen

Computed tomography (CT) scans are a major source of medical radiation exposure worldwide. In countries like China, the frequency of CT scans has grown rapidly, particularly in routine physical examinations where chest CT scans are…

Medical Physics · Physics 2025-04-10 Zirui Ye , Bei Yao , Haoran Zheng , Li Tao , Ripeng Wang , Yankui Chang , Zhi Chen , Yingming Zhao , Wei Wei , Xie George Xu

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT)…

The Computed Tomography (CT) for diagnosis of lesions in human internal organs is one of the most fundamental topics in medical imaging. Low-dose CT, which offers reduced radiation exposure, is preferred over standard-dose CT, and therefore…

Image and Video Processing · Electrical Eng. & Systems 2023-09-26 Wenjie Liu

Implicit neural representations (INRs) provide a parameter-efficient and fully differentiable image model for CT reconstruction. However, optimizing INRs for CT reconstruction using standard auto-differentiation techniques can be…

Image and Video Processing · Electrical Eng. & Systems 2026-04-14 Mahrokh Najaf , Gregory Ongie

Dose reduction in computed tomography (CT) is essential for decreasing radiation risk in clinical applications. Iterative reconstruction is one of the most promising ways to compensate for the increased noise due to reduction of photon…

Image and Video Processing · Electrical Eng. & Systems 2021-03-24 Zhuonan He , Yikun Zhang , Yu Guan , Shanzhou Niu , Yi Zhang , Yang Chen , Qiegen Liu

The widespread adoption of on-board volumetric imaging in cancer radiotherapy has stimulated research efforts to develop online adaptive radiotherapy techniques to handle the inter-fraction variation of the patient's geometry. Such efforts…

Medical Physics · Physics 2015-05-14 Chunhua Men , Xuejun Gu , Dongju Choi , Amitava Majumdar , Ziyi Zheng , Klaus Mueller , Steve B. Jiang

Obtaining accurate and reliable images from low-dose computed tomography (CT) is challenging. Regression convolutional neural network (CNN) models that are learned from training data are increasingly gaining attention in low-dose CT…

Image and Video Processing · Electrical Eng. & Systems 2019-08-06 Il Yong Chun , Xuehang Zheng , Yong Long , Jeffrey A. Fessler

In radiation therapy (RT), the reliance on pre-treatment computed tomography (CT) images encounter challenges due to anatomical changes, necessitating adaptive planning. Daily cone-beam CT (CBCT) imaging, pivotal for therapy adjustment,…

Computer Vision and Pattern Recognition · Computer Science 2024-09-20 Joonil Hwang , Sangjoon Park , NaHyeon Park , Seungryong Cho , Jin Sung Kim

Cone Beam Computed Tomography (CBCT) is widely used in dentistry for diagnostics and treatment planning. CBCT Imaging has a long acquisition time and consequently, the patient is likely to move. This motion causes significant artifacts in…

Computer Vision and Pattern Recognition · Computer Science 2023-04-21 Abdul Salam Rasmi Asraf Ali , Andrea Fusiello , Claudio Landi , Cristina Sarti , Anneke Annassia Putri Siswadi

Total variation (TV) regularization is a popular reconstruction method for ill-posed imaging problems, and particularly useful for applications with piecewise constant targets. However, using TV for medical cone-beam computed X-ray…

Medical Physics · Physics 2024-12-11 Alexander Meaney , Mikael A. K. Brix , Miika T. Nieminen , Samuli Siltanen

This paper proposes a novel and fast self-supervised solution for sparse-view CBCT reconstruction (Cone Beam Computed Tomography) that requires no external training data. Specifically, the desired attenuation coefficients are represented as…

Image and Video Processing · Electrical Eng. & Systems 2022-09-30 Ruyi Zha , Yanhao Zhang , Hongdong Li

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include…

Medical Physics · Physics 2025-09-29 Alzahra Altalib , Chunhui Li , Alessandro Perelli

Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…

Quantum Physics · Physics 2023-09-12 Kyungtaek Jun