English
Related papers

Related papers: R&D for Future 100 kton Scale Liquid Argon Detecto…

200 papers

We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in…

Instrumentation and Detectors · Physics 2026-04-23 Yichen Li , Aleksey Bolotnikov , Milind Diwan , Jay Hyun Jo , Steven Kettell , Steven Linden , Xin Qian , Matteo Vicenzi , Chao Zhang

An ultra-large Liquid Argon Time Projection Chamber-based neutrino detector will have the uncommon ability to detect atmospheric tau neutrino events. This paper discusses the most promising modes for identifying charged current tau neutrino…

High Energy Physics - Phenomenology · Physics 2010-12-09 Janet Conrad , Andre de Gouvea , Shashank Shalgar , Joshua Spitz

We investigate the potential of Liquid Argon (LAr) neutrino detectors to search for millicharged particles, a well-motivated extension of the standard model. Detectors located downstream of an intense proton beam that is striking a target…

High Energy Physics - Phenomenology · Physics 2019-08-02 Roni Harnik , Zhen Liu , Ornella Palamara

We discuss the major scientific issues of the search for proton decay to $10^{35}$ years lifetime and search for CP violation with a VLBL superbeam (~2000 km distance). The 100 kT LANNDD liquid Argon TPC is well matched to these goals. We…

Astrophysics · Physics 2007-05-23 David B. Cline

Long-lived particles (LLPs) arise in many theories beyond the Standard Model. These may be copiously produced from meson decays (or through their mixing with the LLP) at neutrino facilities and leave a visible decay signal in nearby…

High Energy Physics - Phenomenology · Physics 2024-01-26 Pilar Coloma , Justo Martín-Albo , Salvador Urrea

Predicted as possible bound states of up, down and strange quarks, strangelets could be more energetically favourable and more stable than nuclear matter. In this paper we explore the possibility of detecting such particles with the future…

Instrumentation and Detectors · Physics 2021-11-24 Mihaela Parvu , Ionel Lazanu

In this paper we present results from a test of a small Liquid Argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector concept provides a 3D-tracking and calorimetric device capable of charge amplification,…

Instrumentation and Detectors · Physics 2011-07-28 A. Badertscher , A. Curioni , S. Horikawa , L. Knecht , D. Lussi , A. Marchionni , G. Natterer , F. Resnati , A. Rubbia , T. Viant

Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with…

Instrumentation and Detectors · Physics 2015-01-27 M. Sorel

At the beginning of 2010, we presented at the J-PARC PAC an R$&$D program towards large (100 kton scale) liquid argon TPCs, suitable to investigate, in conjunction with the J-PARC neutrino beam, the possibility of CP violation in the…

The ICARUS Detector at the LGNS will carry out a sensitive search for a sin sup 2(2 theta sub 13). We describe a small version for the LANNDD proton decay detector (70kT Liquid Argon) to measure nu sub mu -> nu sub e in a low energy or…

Astrophysics · Physics 2008-11-26 David B. Cline , Stanislaw Otwinowski , Franco Sergiampietri

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between…

Instrumentation and Methods for Astrophysics · Physics 2020-04-22 The DarkSide Collaboration , C. E. Aalseth , S. Abdelhakim , F. Acerbi , P. Agnes , R. Ajaj , I. F. M. Albuquerque , T. Alexander , A. Alici , A. K. Alton , P. Amaudruz , F. Ameli , J. Anstey , P. Antonioli , M. Arba , S. Arcelli , R. Ardito , I. J. Arnquist , P. Arpaia , D. M. Asner , A. Asunskis , M. Ave , H. O. Back , A. Barrado Olmedo , G. Batignani , M. G. Bisogni , V. Bocci , A. Bondar , G. Bonfini , W. Bonivento , E. Borisova , B. Bottino , M. G. Boulay , R. Bunker , S. Bussino , A. Buzulutskov , M. Cadeddu , M. Cadoni , A. Caminata , N. Canci , A. Candela , C. Cantini , M. Caravati , M. Cariello , F. Carnesecchi , M. Carpinelli , A. Castellani , P. Castello , S. Catalanotti , V. Cataudella , P. Cavalcante , D. Cavazza , S. Cavuoti , S. Cebrian , J. M. Cela Ruiz , B. Celano , R. Cereseto , W. Cheng , A. Chepurnov , C. Cicalò , L. Cifarelli , M. Citterio , A. G. Cocco , V. Cocco , M. Colocci , L. Consiglio , F. Cossio , G. Covone , P. Crivelli , I. D'Antone , M. D'Incecco , D. D'Urso , M. D. Da Rocha Rolo , O. Dadoun , M. Daniel , S. Davini , A. De Candia , S. De Cecco , M. De Deo , A. De Falco , G. De Filippis , D. De Gruttola , G. De Guido , G. De Rosa , G. Dellacasa , P. Demontis , S. DePaquale , A. V. Derbin , A. Devoto , F. Di Eusanio , L. Di Noto , G. Di Pietro , P. Di Stefano , C. Dionisi , G. Dolganov , F. Dordei , M. Downing , F. Edalatfar , A. Empl , M. Fernandez Diaz , A. Ferri , C. Filip , G. Fiorillo , K. Fomenko , A. Franceschi , D. Franco , G. E. Froudakis , F. Gabriele , A. Gabrieli , C. Galbiati , P. Garcia Abia , D. Gascón Fora , A. Gendotti , C. Ghiano , A. Ghisi , S. Giagu , P. Giampa , R. A. Giampaolo , C. Giganti , M. A. Giorgi , G. K. Giovanetti , M. L. Gligan , A. Gola , O. Gorchakov , M. Grab , R. Graciani Diaz , F. Granato , M. Grassi , J. W. Grate , G. Y. Grigoriev , A. Grobov , M. Gromov , M. Guan , M. B. B. Guerra , M. Guerzoni , M. Gulino , R. K. Haaland , B. R. Hackett , A. Hallin , B. Harrop , E. W. Hoppe , S. Horikawa , B. Hosseini , F. Hubaut , P. Humble , E. V. Hungerford , An. Ianni , A. Ilyasov , V. Ippolito , C. Jillings , K. Keeter , C. L. Kendziora , S. Kim , I. Kochanek , K. Kondo , G. Kopp , D. Korablev , G. Korga , A. Kubankin , R. Kugathasan , M. Kuss , M. Kuźniak , M. La Commara , L. La Delfa , M. Lai , S. Langrock , M. Lebois , B. Lehnert , N. Levashko , X. Li , Q. Liqiang , M. Lissia , G. U. Lodi , G. Longo , R. López Manzano , R. Lussana , L. Luzzi , A. A. Machado , I. N. Machulin , A. Mandarano , L. Mapelli , M. Marcante , A. Margotti , S. M. Mari , M. Mariani , J. Maricic , M. Marinelli , D. Marras , M. Martínez , J. J. Martínez Morales , A. D. Martinez Rojas , C. J. Martoff , M. Mascia , J. Mason , A. Masoni , A. Mazzi , A. B. McDonald , A. Messina , P. D. Meyers , T. Miletic , R. Milincic , A. Moggi , S. Moioli , J. Monroe , M. Morrocchi , T. Mroz , W. Mu , V. N. Muratova , S. Murphy , C. Muscas , P. Musico , R. Nania , T. Napolitano , A. Navrer Agasson , M. Nessi , I. Nikulin , A. Oleinik , V. Oleynikov , M. Orsini , F. Ortica , L. Pagani , M. Pallavicini , S. Palmas , L. Pandola , E. Pantic , E. Paoloni , G. Paternoster , V. Pavletcov , F. Pazzona , S. Peeters , P. A. Pegoraro , K. Pelczar , L. A. Pellegrini , C. Pellegrino , N. Pelliccia , F. Perotti , V. Pesudo , E. Picciau , C. Piemonte , F. Pietropaolo , A. Pocar , T. Pollman , D. Portaluppi , S. S. Poudel , P. Pralavorio , D. Price , B. Radics , F. Raffaelli , F. Ragusa , M. Razeti , A. Razeto , V. Regazzoni , C. Regenfus , A. L. Renshaw , S. Rescia , M. Rescigno , F. Retiere , L. P. Rignanese , A. Rivetti , A. Romani , L. Romero , N. Rossi , A. Rubbia , D. Sablone , P. Sala , P. Salatino , O. Samoylov , E. Sánchez García , S. Sanfilippo , M. Sant , D. Santone , R. Santorelli , C. Savarese , E. Scapparone , B. Schlitzer , G. Scioli , E. Segreto , A. Seifert , D. A. Semenov , A. Shchagin , A. Sheshukov , S. Siddhanta , M. Simeone , P. N. Singh , P. Skensved , M. D. Skorokhvatov , O. Smirnov , G. Sobrero , A. Sokolov , A. Sotnikov , R. Stainforth , A. Steri , S. Stracka , V. Strickland , G. B. Suffritti , S. Sulis , Y. Suvorov , A. M. Szelc , R. Tartaglia , G. Testera , T. Thorpe , A. Tonazzo , A. Tosi , M. Tuveri , E. V. Unzhakov , G. Usai , A. Vacca , E. Vázquez-Jáuregui , M. Verducci , T. Viant , S. Viel , F. Villa , A. Vishneva , R. B. Vogelaar , M. Wada , J. Wahl , J. J. Walding , H. Wang , Y. Wang , S. Westerdale , R. J. Wheadon , R. Williams , J. Wilson , Marcin Wojcik , Mariusz Wojcik , S. Wu , X. Xiao , C. Yang , Z. Ye , M. Zuffa , G. Zuzel

The four 10 kt Liquid Argon Time Projection Chambers (LArTPCs) of the future DUNE experiment will enable precise measurements of the oscillation parameters and the discovery of CP violation for leptons, thanks to their excellent 3D imaging…

Instrumentation and Detectors · Physics 2019-02-14 Andrea Scarpelli

An ultimate liquid xenon experiment would be limited in its dark matter science reach by irreducible neutrino backgrounds, which are an exciting signal in their own right. To achieve such sensitivity, other backgrounds that currently plague…

High Energy Physics - Experiment · Physics 2024-02-27 Abigail Kopec

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter…

The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to…

Instrumentation and Detectors · Physics 2023-08-22 K. K. Zhao , M. Y. Guan , J. C. Liu , C. G. Yang , S. T. Lin

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon underground detector. The…

Instrumentation and Detectors · Physics 2015-05-13 Vittorio Boccone

WIMPs are a well-motivated galactic dark matter candidate. Liquid argon (LAr) is an attractive target for the direct detection of WIMPs. The LAr prototype detector is designed to study the technology and property of LAr detector. The…

Instrumentation and Detectors · Physics 2016-12-21 Pei-Xian Li , Meng-Yun Guan , Chang-Gen Yang , Peng Zhang , Jin-Chang Liu , Yong-Pen Zhang , Cong Guo , Yi Wang

Liquid Argon Time Projection Chamber detectors are well suited to study neutrino interactions, and are an intriguing option for future massive detectors capable of measuring the parameters that characterize neutrino oscillations. These…

Instrumentation and Detectors · Physics 2010-02-10 M. Soderberg

Tensions in several phenomenological models grew with experimental results on neutrino/antineutrino oscillations at Short-Baseline (SBL) and with the recent, carefully recomputed, antineutrino fluxes from nuclear reactors. At a refurbished…