Related papers: Composite CaWO4 Detectors for the CRESST-II Experi…
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three…
In preparation to the CROSS $2\beta$ decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility at the LSC (Spain). The suspension was tested with two…
The DarkSide-20k experiment represents the present goal of the Global Argon Dark Matter Collaboration program. Bringing together the experience from previous argon-based detectors, as well as the knowledge gained on large volume membrane…
The CRESST experiment observes an unexplained excess of events at low energies. In the current CRESST-III data-taking campaign we are operating detector modules with different designs to narrow down the possible explanations. In this work,…
Three dark matter direct detection experiments (DAMA/LIBRA, CoGeNT, and CRESST-II) have each reported signals which are not consistent with known backgrounds, but resemble that predicted for a dark matter particle with a mass of roughly…
Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…
We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of…
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an…
Cryogenic calorimetric experiments to search for neutrinoless double-beta decay ($0\nu\beta\beta$) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual…
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more…
We report first results from the Cryogenic Dark Matter Search (CDMS II) experiment running with its full complement of 30 cryogenic particle detectors at the Soudan Underground Laboratory. This report is based on the analysis of data…
XENON10 is a new direct dark matter detection experiment using liquid xenon as target for weakly interacting, massive particles (WIMPs). A two-phase (liquid/gas) time projection chamber with 15 kg fiducial mass has been installed in a…
Preliminary results obtained with 320g bolometers with simultaneous ionization and heat measurements are described. After a few weeks of data taking, data accumulated with one of these detectors are beginning to exclude the upper part of…
The simultaneous measurement of phonons and scintillation light induced by incident particles in a scintillating crystal such as CaWO4 is a powerful technique for the active rejection of background induced by gamma's and beta's and even…
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an…
The SuperCDMS experiment searches for weakly interacting massive particles (WIMPs) using cryogenic germanium detectors that measure ionization and phonon energy. Several direct searches for WIMPs have recently reported excesses of events…
The CDMS II experiment uses Z-dependent Ionization Phonon (ZIP) detectors made of Germanium and Silicon to identify nuclear recoils from Weakly Interacting Massive Particles (WIMPs) with near complete event-by-event rejection of various…
An experiment to search for double beta processes in 106Cd by using cadmium tungstate crystal scintillator enriched in 106Cd (106CdWO4) in coincidence with the four crystals HPGe detector GeMulti is in progress at the STELLA facility of the…
The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the…
Direct detection experiments have established the most stringent constraints on potential interactions between particle candidates for relic, thermal dark matter and Standard Model particles. To surpass current exclusion limits a new…