English
Related papers

Related papers: Performance of the CMS Cathode Strip Chambers with…

200 papers

As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the…

Instrumentation and Detectors · Physics 2020-06-02 Sabino Meola

We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN…

High Energy Physics - Experiment · Physics 2012-08-27 The CMS Collaboration

Multi-gap Resistive Plate Chambers (MRPCs) with multi-strip readout are considered to be the optimal detector candidate for the Time-of-Flight (ToF) wall in the Compressed Baryonic Matter (CBM) experiment. In the R&D phase MRPCs with…

Instrumentation and Detectors · Physics 2016-11-23 I. Deppner , N. Herrmann , J. Frühauf , M. Kiš , P. Lyu , P. -A. Loizeau , L. Shi , C. Simon , Y. Wang , B. Xie

The expected performance of track reconstruction with LHC events using the CMS silicon tracker is presented. Track finding and fitting is accomplished with Kalman Filter techniques that achieve efficiencies above 99% on single muons with…

Instrumentation and Detectors · Physics 2010-03-04 Paolo Azzurri

We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron…

Instrumentation and Detectors · Physics 2022-03-09 M. Abbas , M. Abbrescia , H. Abdalla , A. Abdelalim , S. AbuZeid , A. Agapitos , A. Ahmad , A. Ahmed , W. Ahmed , C. Aimè , C. Aruta , I. Asghar , P. Aspell , C. Avila , J. Babbar , Y. Ban , R. Band , S. Bansal , L. Benussi , V. Bhatnagar , M. Bianco , S. Bianco , K. Black , L. Borgonovi , O. Bouhali , A. Braghieri , S. Braibant , S. Butalla , S. Calzaferri , M. Caponero , F. Cassese , N. Cavallo , S. Chauhan , A. Colaleo , J. Collins , A. Conde Garcia , M. Dalchenko , A. De Iorio , G. De Lentdecker , D. Dell Olio , G. De Robertis , W. Dharmaratna , S. Dildick , B. Dorney , R. Erbacher , F. Fabozzi , F. Fallavollita , A. Ferraro , D. Fiorina , E. Fontanesi , M. Franco , C. Galloni , P. Giacomelli , S. Gigli , J. Gilmore , M. Gola , M. Gruchala , A. Gutierrez , R. Hadjiiska , T. Hakkarainen , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , T. Huang , P. Iaydjiev , A. Irshad , A. Iorio , F. Ivone , J. Jaramillo , D. Jeong , V. Jha , A. Juodagalvis , E. Juska , B. Kailasapathy , T. Kamon , P. Karchin , A. Kaur , H. Kaur , H. Keller , H. Kim , J. Kim , A. Kumar , S. Kumar , H. Kumawat , N. Lacalamita , J. S. H. Lee , A. Levin , Q. Li , F. Licciulli , L. Lista , K. Liyanage , F. Loddo , M. Lohan , M. Luhach , M. Maggi , Y. Maghrbi , N. Majumdar , K. Malagalage , S. Malhotra , S. Martiradonna , N. Mccoll , C. McLean , J. Merlin , M. Misheva , D. Mishra , G. Mocellin , L. Moureaux , A. Muhammad , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , P. Netrakanti , S. Nuzzo , R. Oliveira , L. Pant , P. Paolucci , I. C. Park , L. Passamonti , G. Passeggio , A. Peck , N. Perera , L. Petre , H. Petrow , D. Piccolo , D. Pierluigi , G. Raffone , M. Rahmani , F. Ramirez , A. Ranieri , G. Rashevski , M. Ressegotti , C. Riccardi , M. Rodozov , E. Romano , C. Roskas , B. Rossi , P. Rout , D. Roy , J. D. Ruiz , A. Russo , A. Safonov , D. Saltzberg , G. Saviano , A. Shah , A. Sharma , R. Sharma , M. Shopova , F. Simone , J. Singh , E. Soldani , U. Sonnadara , E. Starling , B. Stone , J. Sturdy , G. Sultanov , Z. Szillasi , D. Teague , D. Teyssier , T. Tuuva , M. Tytgat , I. Vai N. Vanegas , R. Venditti , P. Verwilligen , W. Vetens , A. Virdi , P. Vitulo , A. Wajid , D. Wang , K. Wang , I. J. Watson , J. Weatherwax , N. Wickramage , D. D. C. Wickramarathna , Y. Yang , U. Yang , J. Yongho , I. Yoon , Z. You , I. Yu , S. Zaleski

The Compact Muon Solenoid (CMS) detector at the CERN Large Hadron Collider (LHC) is undergoing an extensive Phase II upgrade program to prepare for the challenging conditions of the High-Luminosity LHC (HL-LHC). A new timing layer is…

Instrumentation and Detectors · Physics 2018-10-02 Irene Dutta

The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for…

A description is provided of the software algorithms developed for the CMS tracker both for reconstructing charged-particle trajectories in proton-proton interactions and for using the resulting tracks to estimate the positions of the LHC…

Instrumentation and Detectors · Physics 2014-10-29 CMS Collaboration

In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming…

The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

Single muon triggers are crucial for the physics programmes at hadron collider experiments. To be sensitive to electroweak processes, single muon triggers with transverse momentum thresholds down to 20 GeV and dimuon triggers with even…

Instrumentation and Detectors · Physics 2019-03-27 D. Cieri , S. Abovyan , V. Danielyan , M. Fras , P. Gadow , O. Kortner , S. Kortner , H. Kroha , F. Müller , S. Nowak , P. Richter , K. Schmidt-Sommerfeld

Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In order to optimize their performance, it is of primary…

Instrumentation and Detectors · Physics 2020-06-03 W. Elmetenawee

Due to the muon tomography's capability of imaging high Z materials, some potential applications have been reported on inspecting smuggled nuclear materials in customs. A compact Cosmic Ray Muons (CRM) imaging prototype, Lanzhou University…

The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional…

An extensive system test of the ATLAS muon spectrometer has been performed in the H8 beam line at the CERN SPS during the last four years. This spectrometer will use pressurized Monitored Drift Tube (MDT) chambers and Cathode Strip Chambers…

Instrumentation and Detectors · Physics 2008-11-26 Erez Etzion

The CMS collaboration is constructing the largest silicon tracker ever built with an active silicon area of 200 m^2 to provide robust charged particle tracking and vertex reconstruction within the 4T magnetic field of the CMS Solenoid. The…

Instrumentation and Detectors · Physics 2009-11-11 Gabriella Pasztor

We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in…

The Data Quality Monitoring (DQM) of the Compact Muon Solenoid (CMS) silicon tracking detectors (Tracker) at the Large Hadron Collider (LHC) at CERN is a software based system designed to monitor the detector and reconstruction performance,…

Instrumentation and Detectors · Physics 2019-08-13 V. Adler

A measurement is presented of the flux ratio of positive and negative muons from cosmic ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The excellent…

High Energy Physics - Experiment · Physics 2011-04-22 Lars Sonnenschein

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic…

‹ Prev 1 4 5 6 7 8 10 Next ›