Related papers: Identification and Filtering of Uncharacteristic N…
State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical…
The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online Data Quality Monitoring of the CMS electromagnetic calorimeter is a vital operational tool that allows detector experts to…
Calorimeters operating in high-radiation environments are susceptible to damage, leading to increased noise that can significantly degrade energy resolution. A common way to mitigate noise is to apply a higher energy threshold on the cells,…
A real-time autoencoder-based anomaly detection system using semi-supervised machine learning has been developed for the online Data Quality Monitoring system of the electromagnetic calorimeter of the CMS detector at the CERN LHC. A novel…
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were…
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters…
The first level trigger of the CMS experiment is comprised of custom electronics that process data from the electromagnetic and hadron calorimeters and three technologies of muon detectors in order to select the most interesting events from…
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years…
The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 $\times$…
The Compact Muon Solenoid (CMS) detector is one of two general-purpose detectors that reconstruct the products of high energy particle interactions at the Large Hadron Collider (LHC) at CERN. The silicon pixel detector is the innermost…
Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central…
The CMS experiment will collect data from the proton-proton collisions delivered by the Large Hadron Collider (LHC) at a centre-of-mass energy up to 14 TeV. The CMS trigger system is designed to cope with unprecedented luminosities and LHC…
Throughout the year 2011, the Large Hadron Collider (LHC) has operated with an instantaneous luminosity that has risen continually to around 4x10^33cm-2 s-1. With this prodigious high-energy proton collisions rate, efficient triggering on…
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the…
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate…
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges.…
We present a new publicly available dataset that contains simulated data of a novel calorimeter to be installed at the CERN Large Hadron Collider. This detector will have more than six-million channels with each channel capable of position,…
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics interest from a GHz (MHz) interaction rate of proton-proton…
After nearly two decades of design, construction and commissioning, the CMS detector was operated with colliding LHC proton beams for the first time in November 2009. Collision data were recorded at centre-of-mass energies of 0.9 and 2.36…
We present a new scheme to detect the quantum shot noise in coupled mesoscopic systems. By applying the noise thermometry to the capacitively coupled quantum point contacts (QPCs) we prove that the noise temperature of one QPC is in perfect…