English
Related papers

Related papers: RETGEM with polyvinylchloride (PVC) electrodes

200 papers

We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements…

For today's electronics manufacturing process, the emphasis on stable functionality, durability, and fixed physical forms is designed to ensure long-term usability. However, this focus on robustness and permanence complicates the…

Human-Computer Interaction · Computer Science 2024-06-17 Tingyu Cheng , Zhihan Zhang , Han Huang , Yingting Gao , Wei Sun , Gregory D. Abowd , HyunJoo Oh , Josiah Hester

A Time Projection Chamber (TPC) using micro-pattern gas detectors is planned as the main tracking device for a detector at the next Linear Collider. A novel support structure for Gas Electron Multipliers (GEMs), which minimizes the material…

Instrumentation and Detectors · Physics 2015-06-17 T. Behnke , F. Müller , A. Münnich , K. Zenker

The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with…

Instrumentation and Detectors · Physics 2010-12-06 V. Peskov , M. Cortesi , R. Chechik , A. Breskin

Images of resolved 5.9 keV electron tracks produced from $^{55}$Fe X-ray interactions are presented for the first time using an optical readout time projection chamber (TPC). The corresponding energy spectra are also shown, with the FWHM…

Instrumentation and Detectors · Physics 2024-07-19 N. S. Phan , E. R. Lee , D. Loomba

Earlier we have developed and successfully tested a RICH detector prototype consisting in a CsI coated triple GEM operated in gas flushed mode In the given work, a modified version of this detector for a completely different application -…

Instrumentation and Detectors · Physics 2018-11-14 G. Volpe , V. Peskov

The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON…

Instrumentation and Detectors · Physics 2007-06-11 M. Gai , D. N. McKinsey , K. Ni , D. A. R. Rubin , T. Wongjirad , R. Alon , A. Breskin , M. Cortesi , J. Miyamoto

Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of large GEM foils, however with…

Instrumentation and Detectors · Physics 2018-06-07 M. Posik , B. Surrow

We report on the manufacture of a first batch of approximately 2,000 Gas Electron Multipliers (GEMs) using 3M's fully automated roll to roll flexible circuit production line. This process allows low-cost, reproducible fabrication of a high…

High Energy Physics - Experiment · Physics 2011-05-12 P. S. Barbeau , J. I. Collar , J. D. Geissinger , J. Miyamoto , I. Shipsey , R. Yang

The Resistive Plate Chamber (RPC) is widely used in experiments of high energy physics as trigger detector as its good time resolution and high efficiency. In the traditional layout of RPC, the graphite layers are indispensable parts. The…

Instrumentation and Detectors · Physics 2021-08-31 Quanyin Li , Xiangyu Xie , Zhengwei Xue , Jiajin Ge , Yongjie Sun

The present era has seen tremendous demands for low-cost electrochromic materials for visible-region multicolor display technology, paper-based, flexible, and wearable electronic devices, smart windows, and optoelectronic applications.…

The upgrade of the Resistive Plate Chamber (RPC) detector, in order to increase the detector rate capability and to be able to work efficiently in high rate environment, consists in the reduction of the operating voltage along with the…

Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…

Instrumentation and Detectors · Physics 2011-07-19 M. S. Dixit , J. Dubeau , J. -P. Martin , K. Sachs

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

We report the application of the resistive anode readout method on a two dimensional imaging GEM detector. The resistive anode consists of $6\times6$ cells with the cell size $6~\mathrm{mm}\times6~\mathrm{mm}$. New electronics and DAQ…

Instrumentation and Detectors · Physics 2016-09-06 Xu-Dong Ju , Ming-Yi Dong , Chuan-Xing Zhou , Jing Dong , Yu-Bin Zhao , Hong-Yu Zhang , Hui-Rong Qi , Qun Ou-Yang

We present the capabilities and results of the Parallel Edge-based Tool for Geophysical Electromagnetic modeling (PETGEM), as well as the physical and numerical foundations upon which it has been developed. PETGEM is an open-source and…

Computational Physics · Physics 2018-08-02 Octavio Castillo-Reyes , Josep de la Puente , José María Cela

We have developed a new detector of photons and charged particles- a hole-type structure with electrodes made of a double layered resistive material: a thin low resistive layer coated with a layer having a much higher resistivity. One of…

Instrumentation and Detectors · Physics 2008-11-26 G. Charpak , P. Benaben , P. Breuil , A. Di Mauro , P. Martinengo , V. Peskov

We present design and construction of a large low-mass Triple-GEM detector prototype for forward tracking at a future Electron-Ion Collider. In this environment, multiple scattering of forward and backward tracks must be minimized so that…

Instrumentation and Detectors · Physics 2017-11-16 Marcus Hohlmann , Matthew Bomberger , Stefano Colafranceschi , Francisco Jimenez , Mehdi Rahmani , Aiwu Zhang

Digital and Semi-Digital Hadronic Calorimeters (S)DHCAL were suggested for future Colliders as part of the particle-flow concept. Though studied mostly with RPC-based techniques, investigations have shown that MPGD-based sampling elements…

The first operation of a cryogenic Resistive Plate WELL (RPWELL) detector in the saturated vapor of liquid argon is reported. The RPWELL detector was composed of a Thick Gas Electron Multiplier (THGEM) electrode coupled to a metallic anode…

Instrumentation and Detectors · Physics 2023-12-13 A. Tesi , S. Leardini , L. Moleri , M. Morales , D. Gonzalez-Diaz , A. Jash , A. Breskin , S. Bressler
‹ Prev 1 4 5 6 7 8 10 Next ›