Related papers: Frequency Comparison of Two High-Accuracy Al+ Opti…
We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in…
The highly forbidden $^2$S$_{1/2} \rightarrow ^2$F$_{7/2}$ electric octupole transition in $^{171}$Yb$^+$ is a potential candidate for a redefinition of the SI second. We present a measurement of the absolute frequency of this optical…
Optical clock network requires the establishment of optical frequency transmission link between multiple optical clocks, utilizing narrow linewidth lasers. Despite achieving link noise levels of 10${^{-20}}$, the final accuracy is limited…
Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of $10^{-18}$ and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion…
Atomic clocks have been transformational in science and technology, leading to innovations such as global positioning, advanced communications, and tests of fundamental constant variation. Next-generation optical atomic clocks can extend…
Transition frequencies between low-lying energy levels in a single trapped $^{138}$Ba$^{+}$ ion have been measured with laser spectroscopy referenced to an optical frequency comb. By extracting the frequencies of one-photon and two-photon…
We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is…
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The…
We measured the absolute frequency of the $^1S_0$ - $^3P_0$ transition of $^{171}$Yb atoms confined in a one-dimensional optical lattice relative to the SI second. The determined frequency was 518 295 836 590 863.38(57) Hz. The uncertainty…
We study atomic systems that are in the frequency range of optical atomic clocks and have enhanced sensitivity to potential time-variation of the fine structure constant, alpha. The high sensitivity is due to coherent contributions from…
Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 x 10--19…
Questioning the presumably most basic assumptions about the structure of space and time has revolutionized our understanding of Nature. State-of-the-art atomic clocks make it possible to precisely test fundamental symmetry properties of…
Integrated photonics in trapped-ion systems are critical for the realization of applications such as portable optical atomic clocks and scalable quantum computers. However, system-level integration of all required functionalities remains a…
We demonstrate experimentally the existence of magic wavelengths and determine the ratio of the oscillator strengths for a single trapped ion. For the first time, two magic wavelengths for the 40Ca+ clock-transition are measured…
We report on the development and performance evaluation of an ultra-stable clock laser for an $\rm ^{27}Al^+$ optical clock. The thermal noise limited ultra-stable laser is developed based on a 30 cm long ultra-stable cavity. Three…
A microwave atomic clock scheme based on Rb and Cs atoms trapped in optical lattice with magic wavelength for clock transition is proposed. The ac Stark shift of clock transition due to trapping laser can be canceled at some specific laser…
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on ${}^{115}$In${}^+$ / ${}^{172}$Yb${}^+$ Coulomb crystals. For this purpose, we have developed scalable segmented…
An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the $5s^2 {}^1S_0 \to 5s5p {}^3P_0$ transition of ${}^{87}{\rm Sr}$ atoms as a…
The $^1\mathrm{S}_0$-$^3\mathrm{P}_0$ clock transition frequency $\nu_\text{Sr}$ in neutral $^{87}$Sr has been measured relative to the Cs standard by three independent laboratories in Boulder, Paris, and Tokyo over the last three years.…
We propose here a few selective highly charged ions (HCIs), namely Ni$^{12+}$ and Cu$^{13+}$, Pd$^{12+}$ and Ag$^{13+}$, that not only promise to be very high accurate optical clocks below $10^{-19}$ uncertainties, but also offer quality…