English
Related papers

Related papers: Thermal-noise-limited underground interferometer C…

200 papers

We have developed a scheme for reducing LIGO suspension thermal noise close to violin-mode resonances. The idea is to monitor directly the thermally-induced motion of a small portion of (a ``point'' on) each suspension fiber, thereby…

General Relativity and Quantum Cosmology · Physics 2009-12-31 D. H. Santamore , Yuri Levin

The LIGO experiment aims to detect and study gravitational waves using ground based laser interferometry. A critical factor to the performance of the interferometers, and a major consideration in the design of possible future upgrades, is…

General Relativity and Quantum Cosmology · Physics 2009-11-10 E. J. Daw , J. A. Giaime , D. Lormand , M. Lubinski , J. Zweizig

Any search effort for gravitational waves (GW) using interferometric detectors like LIGO needs to be able to identify if and when noise is coupling into the detector's output signal. The Critical Coupling Likelihood (CCL) method has been…

Data Analysis, Statistics and Probability · Physics 2015-06-03 Cesar A. Costa , Cristina V. Torres

Thermoelastic noise will be the most significant noise source in advanced-LIGO interferometers with sapphire test masses. The standard plan for advanced-LIGO has optimized the optics, within the framework of conventional mirrors, to reduce…

General Relativity and Quantum Cosmology · Physics 2007-05-23 R. O'Shaughnessy , S. Strigin , S. Vyatchanin

We introduce the Michigan Infrared Test Thermal ELT N-band (MITTEN) Cryostat, a new facility for testing infrared detectors with a focus on mid-infrared (MIR) wavelengths (8-13 microns). New generations of large format, deep well, fast…

Instrumentation and Methods for Astrophysics · Physics 2020-12-16 R. Bowens , E. Viges , M. R. Meyer , D. Atkinson , J. Monnier , M. Morgenstern , J. Leisenring , W. Hoffmann

Thermodynamically induced length fluctuations of high-reflectivity mirror coatings put a fundamental limit on sensitivity and stability of precision optical interferometers like gravitational wave detectors and ultra-stable lasers. The main…

We report on the development of a sub-kelvin, single-crystal silicon Fabry-Perot cavity. Operating such a cavity below 1~K should reduce the thermal noise limit of the cavity, and by this way address the current limitations of ultrastable…

Instrumentation and Detectors · Physics 2024-06-13 Joannès Barbarat , Jonathan Gillot , Jacques Millo , Clément Lacroûte , Thomas Legero , Vincent Giordano , Yann Kersalé

A wide range of scintillating bolometers is under investigation for applications in the search for rare events and processes beyond the Standard Model. In this work, we report the first measurement of a natural, non-molybdenum-doped,…

Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of…

General Relativity and Quantum Cosmology · Physics 2015-03-18 Kentaro Somiya , Daniel Heinert , Alexey G. Gurkovsky , Stefan Hild , Ronny Nawrodt , Sergey P. Vyatchanin

In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload…

General Relativity and Quantum Cosmology · Physics 2014-03-05 Y. Sakakibara , N. Kimura , T. Suzuki , K. Yamamoto , D. Chen , S. Koike , C. Tokoku , T. Uchiyama , M. Ohashi , K. Kuroda

GLINT is a nulling interferometer downstream of the SCExAO extreme-adaptive-optics system at the Subaru Telescope (Hawaii, USA), and is a pathfinder instrument for high-contrast imaging of circumstellar environments with photonic…

In modern high precision optical instruments, such as in gravitational wave detectors or frequency references, thermally induced fluctuations in the reflective coatings can be a limiting noise source. This noise, known as coating thermal…

Instrumentation and Detectors · Physics 2017-01-18 S. Gras , H. Yu , W. Yam , D. Martynov , M. Evans

The uncertainty principle, applied naively to the test masses of a laser-interferometer gravitational-wave detector, produces a Standard Quantum Limit (SQL) on the interferometer's sensitivity. It has long been thought that beating this SQL…

General Relativity and Quantum Cosmology · Physics 2010-04-06 Alessandra Buonanno , Yanbei Chen

The AION project has built a tabletop prototype of a single-photon long-baseline atom interferometer using the 87Sr clock transition - a type of quantum sensor designed to search for dark matter and gravitational waves. Our prototype…

Gravitational wave astronomy has now left its infancy and has become an important tool for probing the most violent phenomena in our universe. The LIGO/Virgo-KAGRA collaboration operates ground based detectors which cover the frequency band…

Instrumentation and Methods for Astrophysics · Physics 2021-07-07 Pau Amaro-Seoane , Lea Bischof , Jonathan J. Carter , Marie-Sophie Hartig , Dennis Wilken

The third-generation of gravitational wave observatories, such as the Einstein Telescope (ET) and Cosmic Explorer (CE), aim for an improvement in sensitivity of at least a factor of ten over a wide frequency range compared to the current…

Instrumentation and Methods for Astrophysics · Physics 2022-10-05 A. Utina , A. Amato , J. Arends , C. Arina , M. de Baar , M. Baars , P. Baer , N. van Bakel , W. Beaumont , A. Bertolini , M. van Beuzekom , S. Biersteker , A. Binetti , H. J. M. ter Brake , G. Bruno , J. Bryant , H. J. Bulten , L. Busch , P. Cebeci , C. Collette , S. Cooper , R. Cornelissen , P. Cuijpers , M. van Dael , S. Danilishin , D. Dixit , S. van Doesburg , M. Doets , R. Elsinga , V. Erends , J. van Erps , A. Freise , H. Frenaij , R. Garcia , M. Giesberts , S. Grohmann , H. Van Haevermaet , S. Heijnen , J. V. van Heijningen , E. Hennes , J. -S. Hennig , M. Hennig , T. Hertog , S. Hild , H. -D. Hoffmann , G. Hoft , M. Hopman , D. Hoyland , G. A. Iandolo , C. Ietswaard , R. Jamshidi , P. Jansweijer , A. Jones , P. Jones , N. Knust , G. Koekoek , X. Koroveshi , T. Kortekaas , A. N. Koushik , M. Kraan , M. van de Kraats , S. L. Kranzhoff , P. Kuijer , K. A. Kukkadapu , K. Lam , N. Letendre , P. Li , R. Limburg , F. Linde , J. -P. Locquet , P. Loosen , H. Lueck , M. Martınez , A. Masserot , F. Meylahn , M. Molenaar , C. Mow-Lowry , J. Mundet , B. Munneke , L. van Nieuwland , E. Pacaud , D. Pascucci , S. Petit , Z. Van Ranst , G. Raskin , P. M. Recaman , N. van Remortel , L. Rolland , L. de Roo , E. Roose , J. C. Rosier , D. Ryckbosch , K. Schouteden , A. Sevrin , A. Sider , A. Singha , V. Spagnuolo , A. Stahl , J. Steinlechner , S. Steinlechner , B. Swinkels , N. Szilasi , M. Tacca , H. Thienpont , A. Vecchio , H. Verkooijen , C. H. Vermeer , M. Vervaeke , G. Visser , R. Walet , P. Werneke , C. Westhofen , B. Willke , A. Xhahi , T. Zhang

Future gravitational wave detectors (GWDs) such as Advanced LIGO upgrades and the Einstein Telescope are planned to operate at cryogenic temperatures using crystalline silicon (cSi) test-mass mirrors at an operation wavelength of 1550 nm.…

Suitable shaping (in particular, flattening and broadening) of the laser beam has recently been proposed as an effective device to reduce internal (mirror) thermal noise in advanced gravitational wave interferometric detectors. Based on…

General Relativity and Quantum Cosmology · Physics 2008-11-26 Vincenzo Pierro , Vincenzo Galdi , Giuseppe Castaldi , Innocenzo M. Pinto , Juri Agresti , Riccardo DeSalvo

It has been reported that treating music wire (high carbon steel wire) by cooling to cryogenic temperatures can enhance its mechanical properties with particular reference to those properties important for musical performance. We use such…

Instrumentation and Methods for Astrophysics · Physics 2015-09-30 A. Heptonstall , M. Waller , N. A. Robertson