Related papers: Integrated Atom Detector Based on Field Ionization…
We observe the capture and field ionization of individual atoms near the side wall of a single suspended nanotube. Extremely large cross sections for ionization from an atomic beam are observed at modest voltages due to the nanotube's small…
We present a compact, ionization-based detector for the state-selective and spatially resolved measurement of individual Rydberg atoms trapped in the vicinity of an atom chip. The system combines an electrostatic lens system for guiding…
We observe a fast Penning ionization in a dilute gas of cold rubidium Rydberg atoms, in the presence of a static electric field of 50 V/cm, with the ionization rate coefficients for two specific states being measured, which are orders of…
Quantum sensing techniques have been successful in pushing the sensitivity limits in numerous fields, and hold great promise for scanning probes that study nano-scale devices and novel materials. However, forming a nano-scale qubit that is…
In this paper, a carbon nanotube (CNT) based single-ion detector is proposed and its performance is evaluated with atomistic quantum transport models. The sensor can detect any ion type without molecule-specific functionalization and allows…
The electric fields near the heterogeneous metal/dielectric surface of an atom chip were measured using cold atoms. The atomic sensitivity to electric fields was enhanced by exciting the atoms to Rydberg states that are 10^8 times more…
The electron signals from the field ionization of two closely-spaced Rydberg states of \mbox{rubidium-85} are separated using quantum control. In selective field ionization, the state distribution of a collection of Rydberg atoms is…
The authors report on the use of carbon nanofiber nanoemitters to ionize deuterium atoms for the generation of neutrons in a deuterium-deuterium reaction in a preloaded target. Acceleration voltages in the range of 50-80 kV are used. Field…
We present a method for performing low frequency electric field sensing via ionization detection of Rydberg atoms in a collimated atomic beam. A collimated beam avoids much of the electric field screening effects that are common in warm…
We experimentally investigate a scheme for detecting single atoms magnetically trapped on an atom chip. The detector is based on the photoionization of atoms and the subsequent detection of the generated ions. We describe the…
We perform balanced homodyne detection of the electromagnetic field in a single-mode tapered optical nanofiber surrounded by rubidium atoms in a magneto-optical trap. Resonant fluorescence of atoms into the nanofiber mode manifests itself…
The entanglement of two atoms (ions) doped into a carbon nanotube has been investigated theoretically. Based on the photon Green function formalism for quantizing electromagnetic field in the presence of carbon nanotubes, small-diameter…
This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to…
We report on the application of Atomic Force Microscopy (AFM) for studying the Field Emission (FE) properties of a dense array of long and vertically quasi-aligned multi-walled carbon nanotubes grown by catalytic Chemical Vapor Deposition…
A two-step photoionization strategy of an ultracold rubidium beam for application in a focused ion beam instrument is analyzed and implemented. In this strategy the atomic beam is partly selected with an aperture after which the transmitted…
We report on a measurement of the characteristic temperature of an ultracold rubidium ion source, in which a cloud of laser-cooled atoms is converted to ions by photo-ionization. Extracted ion pulses are focused on a detector with a…
In recent years, compact nanodosimetric detectors based on ion multiplication in low-pressure gas have been developed and gained attention in the scientific community. These detectors use strong electric fields to collect and multiply…
We demonstrate superconducting nanowire single photon detectors with 76 +/- 4 % system detection efficiency at a wavelength of 315 nm and an operating temperature of 3.2 K, with a background count rate below 1 count per second at saturated…
We report on the observation and numerical calculation of ionization spectra of highly Stark-shifted Rydberg states of rubidium beyond the classical ionization threshold. In the numerical calculations, a complex absorbing potential (CAP)…
We investigate a technique for detecting radio-frequency (RF) electric fields in a Cesium (Cs) vapor cell at room temperature by collecting charge from ionized Rydberg atoms and compare its performance with the established method of…