English
Related papers

Related papers: Liquid-Argon Time Projection Chambers in the U.S

200 papers

The concept of the LAr TPC technology that is an excellent tracking - calorimeter detector will be used for the next generations of neutrino experiments. In this class of detectors both the scintillation light emitted and the charge…

Instrumentation and Detectors · Physics 2018-09-26 Mihaela Pârvu , I. Lazanu

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The…

We describe the design and performance of a 260-liter liquid argon (LAr) cryogenic test stand for liquid argon detector research and development at BNL. The system uses gas-phase argon purification with continuous pump-free circulation, in…

Instrumentation and Detectors · Physics 2026-04-23 Yichen Li , Aleksey Bolotnikov , Milind Diwan , Jay Hyun Jo , Steven Kettell , Steven Linden , Xin Qian , Matteo Vicenzi , Chao Zhang

The electron scattering has been a vital tool to study the properties of the target nucleus for over five decades. Though, the particular interest on $^{40}$Ar nucleus stemmed from the progress in the accelerator-based neutrino-oscillation…

The T2K experiment is designed to study neutrino oscillation properties by directing a high intensity neutrino beam produced at J-PARC in Tokai, Japan, towards the large Super-Kamiokande detector located 295 km away, in Kamioka, Japan. The…

Instrumentation and Detectors · Physics 2015-03-17 T2K ND280 TPC collaboration

The DUNE Near Detector design consists of multiple components, each designed to produce complementary constraints on flux and neutrino interaction systematic uncertainties for the oscillation analyses. One of these subdetectors is a…

Instrumentation and Detectors · Physics 2019-10-16 Kirsty Duffy

The Liquid Argon Time Projection Chamber (LArTPC) is a powerful dual calorimeter capable of estimating particle energy from both ionization charge and scintillation light. Our study shows that, due to the recombination luminescence, the…

Instrumentation and Detectors · Physics 2025-02-17 Xuyang Ning , Wei Shi , Chao Zhang , Ciro Riccio , Jay Hyun Jo

We have constructed a liquid Argon TPC detector with fiducial mass of 150 kg as a part of the R&D program of the next generation neutrino and nucleon decay detector. This paper describes a study of particle identification performance of the…

We present a new technology for the shaping of the electric field in Time Projection Chambers (TPCs) using a carbon-loaded polyimide foil. This technology allows for the minimisation of passive material near the active volume of the TPC and…

Liquid argon is being employed as a detector medium in neutrino physics and Dark Matter searches. A recent push to expand the applications of scintillation light in Liquid Argon Time Projection Chamber neutrino detectors has necessitated…

Instrumentation and Detectors · Physics 2021-04-26 D. Garcia-Gamez , P. Green , A. M. Szelc

Tests with cosmic ray muons of a small liquid argon time projection chamber (LAr TPC) in a magnetic field of 0.55 T are described. No effect of the magnetic field on the imaging properties were observed. In view of a future large,…

Instrumentation and Detectors · Physics 2011-07-28 A. Badertscher , L. Knecht , M. Laffranchi , G. Natterer , A. Rubbia , Th. Strauss

Liquid argon detectors, with mass up to 100 kton, are being actively studied in the context of proton decay searches, neutrino astrophysics and for the next generation of long baseline neutrino oscillation experiments to study the neutrino…

Instrumentation and Detectors · Physics 2011-08-17 Alessandro Curioni

A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and…

Instrumentation and Detectors · Physics 2012-10-01 M. Antonello , D. Bagliani , B. Baibussinov , H. Bilokon , F. Boffelli , M. Bonesini , E. Calligarich , N. Canci , S. Centro , A. Cesana , K. Cieslik , D. B. Cline , A. G. Cocco , D. Dequal , A. Dermenev , R. Dolfini , M. De Gerone , S. Dussoni , C. Farnese , A. Fava , A. Ferrari , G. Fiorillo , G. T. Garvey , F. Gatti , D. Gibin , S. Gninenko , F. Guber , A. Guglielmi , M. Haranczyk , J. Holeczek , A. Ivashkin , M. Kirsanov , J. Kisiel , I. Kochanek , A. Kurepin , J. Lagoda , G. Lucchini , W. C. Louis , S. Mania , G. Mannocchi , S. Marchini , V. Matveev , A. Menegolli , G. Meng , G. B. Mills , C. Montanari , M. Nicoletto , S. Otwinowski , T. J. Palczewki , G. Passardi , F. Perfetto , P. Picchi , F. Pietropaolo , P. Plonski , A. Rappoldi , G. L. Raselli , M. Rossella , C. Rubbia , P. Sala , A. Scaramelli , E. Segreto , D. Stefan , J. Stepaniak , R. Sulej , O. Suvorova , M. Terrani , D. Tlisov , R. G. Van de Water , G. Trinchero , M. Turcato , F. Varanini , S. Ventura , C. Vignoli , H. G. Wang , X. Yang , A. Zani , K Zaremba , M. Benettoni , P. Bernardini , A. Bertolin , R. Brugnera , M. Calabrese , A. Cecchetti , S. Cecchini , G. Collazuol , P. Creti , F. Dal Corso , A. Del Prete , I. De Mitri , G. De Robertis , M. De Serio , L. Degli Esposti , D. Di Ferdinando , U. Dore , S. Dusini , P. Fabbricatore , C. Fanin , R. A. Fini , G. Fiore , A. Garfagnini , G. Giacomelli , R. Giacomelli , C. Guandalini , M. Guerzoni , U. Kose , G. Laurenti , M. Laveder , I. Lippi , F. Loddo , A. Longhin , P. Loverre , G. Mancarella , G. Mandrioli , A. Margiotta , G. Marsella , N. Mauri , E. Medinaceli , A. Mengucci , M. Mezzetto , R. Michinelli , M. T. Muciaccia , D. Orecchini , A. Paoloni , G. Papadia , A. Pastore , L. Patrizii , M. Pozzato , G. Rosa , Z. Sahnounm , S. Simone , M. Sioli , G. Sirri , M. Spurio , L. Stanco , A. Surdo , M. Tenti , V. Togo , M. Ventura , M. Zago

In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key…

Instrumentation and Detectors · Physics 2022-03-07 D. Caratelli , W. Foreman , A. Friedland , S. Gardiner , I. Gil-Botella , G. Karagiorgi , M. Kirby , G. Lehmann Miotto , B. R. Littlejohn , M. Mooney , J. Reichenbacher , A. Sousa , K. Scholberg , J. Yu , T. Yang , S. Andringa , J. Asaadi , T. J. C. Bezerra , F. Capozzi , F. Cavanna , E. Church , A. Himmel , T. Junk , J. Klein , I. Lepetic , S. Li , P. Sala , H. Schellman , M. Sorel , J. Wang , M. H. L. S. Wang , W. Wu , J. Zennamo , M. A. Acero , M. R. Adames , H. Amar , D. A. Andrade , C. Andreopoulos , A. M. Ankowski , M. A. Arroyave , V. Aushev , M. A. Ayala-Torres , P. Baldi , C. Backhouse , A. B. Balantekin , W. A. Barkhouse , P. Barham Alzas , J. L. Barrow , J. B. R. Battat , M. C. Q. Bazetto , J. F. Beacom , B. Behera , G. Bellettini , J. Berger , A. T. Bezerra , J. Bian , B. Bilki , B. Bles , T. Bolton , L. Bomben , M. Bonesini , C. Bonilla-Diaz , F. Boran , A. N. Borkum , N. Bostan , D. Brailsford , A. Branca , G. Brunetti , T. Cai , A. Chappell , N. Charitonidis , P. H. P. Cintra , E. Conley , T. E. Coan , P. Cova , L. M. Cremaldi , J. I. Crespo-Anadon , C. Cuesta , R. Dallavalle , G. S. Davies , S. De , P. Dedin Neto , M. Delgado , N. Delmonte , P. B. Denton , A. De Roeck , R. Dharmapalan , Z. Djurcic , F. Dolek , S. Doran , R. Dorrill , K. E. Duffy , B. Dutta , O. Dvornikov , S. Edayath , J. J. Evans , A. C. Ezeribe , A. Falcone , M. Fani , J. Felix , Y. Feng , L. Fields , P. Filip , G. Fiorillo , D. Franco , D. Garcia-Gamez , A. Giri , O. Gogota , S. Gollapinni , M. Goodman , E. Gramellini , R. Gran , P. Granger , C. Grant , S. E. Greenberg , M. Groh , R. Guenette , D. Guffanti , D. A. Harris , A. Hatzikoutelis , K. M. Heeger , M. Hernandez Morquecho , K. Herner , J. Ho , P C. Holanda , N. Ilic , C. M. Jackson , W. Jang , H. -Th. Janka , J. H. Jo , F. R. Joaquim , R. S. Jones , N. Jovancevic , Y. -J. Jwa , D. Kalra , D. M. Kaplan , I. Katsioulas , E. Kearns , K. J. Kelly , E. Kemp , W. Ketchum , A. Kish , L. W. Koerner , T. Kosc , K. Kothekar , I. Kreslo , S. Kubota , V. A. Kudryavtsev , P. Kumar , T. Kutter , J. Kvasnicka , I. Lazanu , T. LeCompte , Y. Li , Y. Liu , M. Lokajicek , W. C. Louis , K. B. Luk , X. Luo , P. A. N. Machado , I. M. Machulin , K. Mahn , M. Man , R. C. Mandujano , J. Maneira , A. Marchionni , D. Marfatia , F. Marinho , C. Mariani , C. M. Marshall , F. Martinez Lopez , D. A. Martinez Caicedo , A. Mastbaum , M. Matheny , N. McConkey , P. Mehta , O. E. B. Messer , A. Minotti , O. G. Miranda , P. Mishra , I. Mocioiu , A. Mogan , R. Mohanta , T. Mohayai , C. Montanari , L. M. Montano Zetina , A. F. Moor , D. Moretti , C. A. Moura , L. M. Mualem , J. Nachtman , S. Narita , A. Navrer-Agasson , M. Nebot-Guinot , J. Nikolov , J. A. Nowak , J. P. Ochoa-Ricoux , E. O'Connor , Y. Onel , Y. Onishchuk , G. D. Orebi Gann , V. Pandey , E. G. Parozzi , S. Parveen , M. Parvu , R. B. Patterson , L. Paulucci , V. Pec , S. J. M. Peeters , F. Pompa , N. Poonthottathil , S. S. Poudel , F. Psihas , A. Rafique , B. J. Ramson , J. S. Real , A. Rikalo , M. Ross-Lonergan , B. Russell , S. Sacerdoti , N. Sahu , D. A. Sanders , D. Santoro , M. V. Santos , C. R. Senise , P. N. Shanahan , H. R Sharma , R. K. Sharma , W. Shi , S. Shin , J. Singh , J. Singh , L. Singh , P. Singh , V. Singh , M. Soderberg , S. Soldner-Rembold , J. Soto-Oton , K. Spurgeon , A. F. Steklain , F. Stocker , T. Stokes , J. Strait , M. Strait , T. Strauss , L. Suter , R. Svoboda , A. M. Szelc , M. Szydagis , E. Tarpara , E. Tatar , F. Terranova , G. Testera , N. Chithirasree , N. Todorovic , A. Tonazzo , M. Torti , F. Tortorici , M. Toups , D. Q. Tran , M. Travar , Y. -D. Tsai , Y. -T. Tsai , S. Z. Tu , J. Urheim , H. Utaegbulam , S. Valder , G. A. Valdiviesso , R. Valentim , S. Vergani , B. Viren , A. Vranicar , B. Wang , D. Waters , P. Weatherly , M. Weber , H. Wei , S. Westerdale , L. H. Whitehead , D. Whittington , A. Wilkinson , R. J. Wilson , M. Worcester , K. Wresilo , B. Yaeggy , G. Yang , J. Zalesak , B. Zamorano , J. Zuklin

We report the first measurement of the flux-integrated cross section of $\nu_{\mu}$ charged-current single $\pi^{0}$ production on argon. This measurement is performed with the MicroBooNE detector, an 85 ton active mass liquid argon time…

High Energy Physics - Experiment · Physics 2023-02-18 MicroBooNE collaboration , C. Adams , M. Alrashed , R. An , J. Anthony , J. Asaadi , A. Ashkenazi , M. Auger , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , A. Bhat , K. Bhattacharya , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , I. Caro Terrazas , R. Carr , R. Castillo Fernandez , F. Cavanna , G. Cerati , Y. Chen , E. Church , D. Cianci , E. O. Cohen , G. H. Collin , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , M. Del Tutto , D. Devitt , A. Diaz , K. Duffy , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , J. J. Evans , A. A. Fadeeva , R. S. Fitzpatrick , B. T. Fleming , D. Franco , A. P. Furmanski , D. Garcia-Gamez , V. Genty , D. Goeldi , S. Gollapinni , O. Goodwin , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , P. Guzowski , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , G. A. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , X. Ji , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , Y. -J. Jwa , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , I. Lepetic , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , S. Marcocci , C. Mariani , J. Marshall , J. Martin-Albo , D. A. Martinez Caicedo , A. Mastbaum , V. Meddage , T. Mettler , K. Mistry , A. Mogan , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , M. Murphy , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Pandey , V. Paolone , A. Papadopoulou , V. Papavassiliou , S. F. Pate , Z. Pavlovic , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , A. Rafique , L. Ren , L. Rochester , M. Ross-Lonergan , C. Rudolf von Rohr , B. Russell , G. Scanavini , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , K. Sutton , S. Sword-Fehlberg , A. M. Szelc , N. Tagg , W. Tang , K. Terao , M. Thomson , R. T. Thornton , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , H. Wei , D. A. Wickremasinghe , K. Wierman , Z. Williams , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , G. Yarbrough , L. E. Yates , G. P. Zeller , J. Zennamo , C. Zhang

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a…

High Energy Physics - Experiment · Physics 2026-02-12 MicroBooNE collaboration , P. Abratenko , D. Andrade Aldana , L. Arellano , J. Asaadi , A. Ashkenazi , S. Balasubramanian , B. Baller , A. Barnard , G. Barr , D. Barrow , J. Barrow , V. Basque , J. Bateman , B. Behera , O. Benevides Rodrigues , S. Berkman , A. Bhat , M. Bhattacharya , V. Bhelande , A. Binau , M. Bishai , A. Blake , B. Bogart , T. Bolton , M. B. Brunetti , L. Camilleri , D. Caratelli , F. Cavanna , G. Cerati , A. Chappell , Y. Chen , J. M. Conrad , M. Convery , L. Cooper-Troendle , J. I. Crespo-Anadon , R. Cross , M. Del Tutto , S. R. Dennis , P. Detje , R. Diurba , Z. Djurcic , K. Duffy , S. Dytman , B. Eberly , P. Englezos , A. Ereditato , J. J. Evans , C. Fang , B. T. Fleming , W. Foreman , D. Franco , A. P. Furmanski , F. Gao , D. Garcia-Gamez , S. Gardiner , G. Ge , S. Gollapinni , E. Gramellini , P. Green , H. Greenlee , L. Gu , W. Gu , R. Guenette , P. Guzowski , L. Hagaman , M. D. Handley , O. Hen , A. Hergenhan , M. Harrison , S. Hawkins , C. Hilgenberg , G. A. Horton-Smith , A. Hussain , B. Irwin , M. S. Ismail , C. James , X. Ji , J. H. Jo , A. Johnson , R. A. Johnson , D. Kalra , G. Karagiorgi , W. Ketchum , A. Kelly , M. Kirby , T. Kobilarcik , K. Kumar , N. Lane , J. -Y. Li , Y. Li , K. Lin , B. R. Littlejohn , L. Liu , S. Liu , W. C. Louis , X. Luo , T. Mahmud , N. Majeed , C. Mariani , J. Marshall , N. Martinez , D. A. Martinez Caicedo , F. Martinez Lopez , M. G. Manuel Alves , S. Martynenko , A. Mastbaum , I. Mawby , N. McConkey , B. McConnell , L. Mellet , J. Mendez , J. Micallef , T. Mohayai , A. Mogan , M. Mooney , A. F. Moor , C. D. Moore , L. Mora Lepin , M. A. Hernandez Morquecho , M. M. Moudgalya , S. Mulleria Babu , D. Naples , A. Navrer-Agasson , N. Nayak , M. Nebot-Guinot , C. Nguyen , L. Nguyen , J. Nowak , N. Oza , O. Palamara , N. Pallat , V. Paolone , A. Papadopoulou , V. Papavassiliou , H. Parkinson , S. F. Pate , N. Patel , Z. Pavlovic , E. Piasetzky , K. Pletcher , I. Pophale , X. Qian , J. L. Raaf , V. Radeka , A. Rafique , M. Reggiani-Guzzo , J. Rodriguez Rondon , M. Rosenberg , M. Ross-Lonergan , I. Safa , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , R. Sharankova , J. Shi , L. Silva , E. L. Snider , S. Soldner-Rembold , J. Spitz , M. Stancari , J. St. John , T. Strauss , A. M. Szelc , N. Taniuchi , K. Terao , C. Thorpe , D. Torbunov , D. Totani , M. Toups , A. Trettin , Y. -T. Tsai , J. Tyler , M. A. Uchida , T. Usher , B. Viren , J. Wang , L. Wang , M. Weber , H. Wei , A. J. White , S. Wolbers , T. Wongjirad , K. Wresilo , W. Wu , E. Yandel , T. Yang , L. E. Yates , H. W. Yu , G. P. Zeller , J. Zennamo , C. Zhang , Y. Zhang

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful…

Predicted as possible bound states of up, down and strange quarks, strangelets could be more energetically favourable and more stable than nuclear matter. In this paper we explore the possibility of detecting such particles with the future…

Instrumentation and Detectors · Physics 2021-11-24 Mihaela Parvu , Ionel Lazanu

The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to…

Instrumentation and Detectors · Physics 2023-08-22 K. K. Zhao , M. Y. Guan , J. C. Liu , C. G. Yang , S. T. Lin