English
Related papers

Related papers: ATLAS Muon Detector Commissioning

200 papers

The Level-1 Muon Barrel Trigger of the ATLAS Experiment at LHC makes use of Resistive Plate Chamber (RPC) detectors. The on-detector trigger electronics modules are able to identify muons with predefined transverse momentum values (pT) by…

Instrumentation and Detectors · Physics 2018-06-27 V. Izzo , A. Aloisio , R. Giordano , S. Perrella , R. Vari

The ALICE muon trigger (MTR) system consists of 72 Resistive Plate Chamber (RPC) detectors arranged in two stations, each composed of two planes with 18 RPCs per plane. The detectors are operated in maxi-avalanche mode using a mixture of…

The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose neutrino experiment designed to measure the neutrino mass hierarchy using a central detector (CD), which contains 20 kton liquid scintillator (LS) surrounded by about…

Instrumentation and Detectors · Physics 2018-03-29 Kun Zhang , Miao He , Weidong Li , Jilei Xu

This work presents a novel cosmic-ray scattering experiment employing a Resistive Plate Chambers (RPC) muon tomography system. By introducing the scattering angle between incident and outgoing cosmic-ray tracks as a key observable, this…

The CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

Muon radiography is an imaging technique based on muon absorption in matter that allows measurement of internal details in hidden objects or structures. This technique relies on measuring cosmic-ray muons tracks accurately, which reflects…

Instrumentation and Detectors · Physics 2025-10-23 Yu Wang , Shubin Liu , Zhihang Yao , Yulin Liu , Zhiyong Zhang , Zhengyang He , Ziwen Pan , Changqing Feng

The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap…

Instrumentation and Detectors · Physics 2015-06-22 G. Pugliese

The performance of all subsystems of the CMS muon detector has been studied by using a sample of proton--proton collision data at sqrt(s) = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40…

Instrumentation and Detectors · Physics 2014-03-12 The CMS Collaboration

The Muon ATLAS MicroMegas Activity (MAMMA) focuses on the development and testing of large-area muon detectors based on the bulk-Micromegas technology. These detectors are candidates for the upgrade of the ATLAS Muon System in view of the…

Instrumentation and Detectors · Physics 2011-11-03 George Iakovidis , Kostantinos Karakostas , Matthias Schott

CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope…

Instrumentation and Detectors · Physics 2010-11-19 Borislav Pavlov

Highly selective triggers are essential for the physics programme of the ATLAS experiment at HL-LHC where the instantaneous luminosity will be about an order of magnitude larger than the LHC instantaneous luminosity in Run 1. The first…

Instrumentation and Detectors · Physics 2016-10-04 H. Kroha , S. Nowak

The measurement of the muon inclusive differential cross section dsigma/dpT in pp collisions at sqrt(s)=7 TeV with the ATLAS detector is presented. The analysis is performed in the pseudorapidity interval |eta|< 2.5 for muon of transverse…

High Energy Physics - Experiment · Physics 2016-11-25 Silvia Franchino

The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by…

Instrumentation and Detectors · Physics 2016-08-09 V. I. Klyukhin , N. Amapane , A. Ball , B. Curé , A. Gaddi , H. Gerwig , A. Hervé , M. Mulders , R. Loveless

The ATLAS experiment at the Large Hadron Collider (LHC) will face the challenge of efficiently selecting interesting candidate events in $pp$ collisions at 14 TeV centre-of-mass energy, whilst rejecting the enormous number of background…

Instrumentation and Detectors · Physics 2008-10-21 Tomasz Bold , for Atlas Tdaq

We have performed the measurement of the cosmic ray muon charge ratio, as a function of the muon momentum, using data collected by the CMS experiment, exploiting the capabilities of the muon barrel drift tube (DT) chambers. The cosmic muon…

High Energy Physics - Experiment · Physics 2008-10-21 M. Aldaya , P. Garcia-Abia

The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at…

To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10…

Instrumentation and Methods for Astrophysics · Physics 2021-04-16 The Pierre Auger Collaboration , A. Aab , P. Abreu , M. Aglietta , J. M. Albury , I. Allekotte , A. Almela , J. Alvarez-Muñiz , R. Alves Batista , G. A. Anastasi , L. Anchordoqui , B. Andrada , S. Andringa , C. Aramo , P. R. Araújo Ferreira , J. C. Arteaga Velázquez , H. Asorey , P. Assis , G. Avila , A. M. Badescu , A. Bakalova , A. Balaceanu , F. Barbato , R. J. Barreira Luz , K. H. Becker , J. A. Bellido , C. Berat , M. E. Bertaina , X. Bertou , P. L. Biermann , T. Bister , J. Biteau , J. Blazek , C. Bleve , M. Boháčová , D. Boncioli , C. Bonifazi , L. Bonneau Arbeletche , N. Borodai , A. M. Botti , J. Brack , T. Bretz , P. G. Brichetto Orchera , F. L. Briechle , P. Buchholz , A. Bueno , S. Buitink , M. Buscemi , K. S. Caballero-Mora , L. Caccianiga , F. Canfora , I. Caracas , J. M. Carceller , R. Caruso , A. Castellina , F. Catalani , G. Cataldi , L. Cazon , M. Cerda , J. A. Chinellato , K. Choi , J. Chudoba , L. Chytka , R. W. Clay , A. C. Cobos Cerutti , R. Colalillo , A. Coleman , M. R. Coluccia , R. Conceição , A. Condorelli , G. Consolati , F. Contreras , F. Convenga , D. Correia dos Santos , C. E. Covault , S. Dasso , K. Daumiller , B. R. Dawson , J. A. Day , R. M. de Almeida , J. de Jesús , S. J. de Jong , G. De Mauro , J. R. T. de Mello Neto , I. De Mitri , J. de Oliveira , D. de Oliveira Franco , F. de Palma , V. de Souza , E. De Vito , M. del Río , O. Deligny , A. Di Matteo , C. Dobrigkeit , J. C. D'Olivo , R. C. dos Anjos , M. T. Dova , J. Ebr , R. Engel , I. Epicoco , M. Erdmann , C. O. Escobar , A. Etchegoyen , H. Falcke , J. Farmer , G. Farrar , A. C. Fauth , N. Fazzini , F. Feldbusch , F. Fenu , B. Fick , J. M. Figueira , A. Filipčič , T. Fodran , M. M. Freire , T. Fujii , A. Fuster , C. Galea , C. Galelli , B. García , A. L. Garcia Vegas , H. Gemmeke , F. Gesualdi , A. Gherghel-Lascu , P. L. Ghia , U. Giaccari , M. Giammarchi , M. Giller , J. Glombitza , F. Gobbi , F. Gollan , G. Golup , M. Gómez Berisso , P. F. Gómez Vitale , J. P. Gongora , J. M. González , N. González , I. Goos , D. Góra , A. Gorgi , M. Gottowik , T. D. Grubb , F. Guarino , G. P. Guedes , E. Guido , S. Hahn , P. Hamal , M. R. Hampel , P. Hansen , D. Harari , V. M. Harvey , A. Haungs , T. Hebbeker , D. Heck , G. C. Hill , C. Hojvat , J. R. Hörandel , P. Horvath , M. Hrabovský , T. Huege , J. Hulsman , A. Insolia , P. G. Isar , P. Janecek , J. A. Johnsen , J. Jurysek , A. Kääpä , K. H. Kampert , B. Keilhauer , J. Kemp , H. O. Klages , M. Kleifges , J. Kleinfeller , M. Köpke , N. Kunka , B. L. Lago , R. G. Lang , N. Langner , M. A. Leigui de Oliveira , V. Lenok , A. Letessier-Selvon , I. Lhenry-Yvon , D. Lo Presti , L. Lopes , R. López , L. Lu , Q. Luce , A. Lucero , J. P. Lundquist , A. Machado Payeras , G. Mancarella , D. Mandat , B. C. Manning , J. Manshanden , P. Mantsch , S. Marafico , A. G. Mariazzi , I. C. Mariş , G. Marsella , D. Martello , H. Martinez , O. Martínez Bravo , M. Mastrodicasa , H. J. Mathes , J. Matthews , G. Matthiae , E. Mayotte , P. O. Mazur , G. Medina-Tanco , D. Melo , A. Menshikov , K. -D. Merenda , S. Michal , M. I. Micheletti , L. Miramonti , S. Mollerach , F. Montanet , C. Morello , M. Mostafá , A. L. Müller , M. A. Muller , K. Mulrey , R. Mussa , M. Muzio , W. M. Namasaka , A. Nasr-Esfahani , L. Nellen , M. Niculescu-Oglinzanu , M. Niechciol , D. Nitz , D. Nosek , V. Novotny , L. Nožka , A Nucita , L. A. Núñez , M. Palatka , J. Pallotta , P. Papenbreer , G. Parente , A. Parra , M. Pech , F. Pedreira , J. Pękala , R. Pelayo , J. Peña-Rodriguez , E. E. Pereira Martins , J. Perez Armand , C. Pérez Bertolli , M. Perlin , L. Perrone , S. Petrera , T. Pierog , M. Pimenta , V. Pirronello , M. Platino , B. Pont , M. Pothast , P. Privitera , M. Prouza , A. Puyleart , S. Querchfeld , J. Rautenberg , D. Ravignani , M. Reininghaus , J. Ridky , F. Riehn , M. Risse , V. Rizi , W. Rodrigues de Carvalho , J. Rodriguez Rojo , M. J. Roncoroni , M. Roth , E. Roulet , A. C. Rovero , P. Ruehl , S. J. Saffi , A. Saftoiu , F. Salamida , H. Salazar , G. Salina , J. D. Sanabria Gomez , F. Sánchez , E. M. Santos , E. Santos , F. Sarazin , R. Sarmento , C. Sarmiento-Cano , R. Sato , P. Savina , C. M. Schäfer , V. Scherini , H. Schieler , M. Schimassek , M. Schimp , F. Schlüter , D. Schmidt , O. Scholten , P. Schovánek , F. G. Schröder , S. Schröder , J. Schulte , S. J. Sciutto , M. Scornavacche , A. Segreto , S. Sehgal , R. C. Shellard , G. Sigl , G. Silli , O. Sima , R. Šmída , P. Sommers , J. F. Soriano , J. Souchard , R. Squartini , M. Stadelmaier , D. Stanca , S. Stanič , J. Stasielak , P. Stassi , A. Streich , M. Suárez-Durán , T. Sudholz , T. Suomijärvi , A. D. Supanitsky , J. Šupík , Z. Szadkowski , A. Taboada , A. Tapia , C. Taricco , C. Timmermans , O. Tkachenko , P. Tobiska , C. J. Todero Peixoto , B. Tomé , A. Travaini , P. Travnicek , C. Trimarelli , M. Trini , M. Tueros , R. Ulrich , M. Unger , L. Vaclavek , M. Vacula , J. F. Valdés Galicia , L. Valore , E. Varela , V. Varma K. C. , A. Vásquez-Ramírez , D. Veberič , C. Ventura , I. D. Vergara Quispe , V. Verzi , J. Vicha , J. Vink , S. Vorobiov , H. Wahlberg , C. Watanabe , A. A. Watson , M. Weber , A. Weindl , L. Wiencke , H. Wilczyński , T. Winchen , M. Wirtz , D. Wittkowski , B. Wundheiler , A. Yushkov , O. Zapparrata , E. Zas , D. Zavrtanik , M. Zavrtanik , L. Zehrer , A. Zepeda

Research on a large-area, cost-effective Muon Telescope Detector has been carried out for RHIC and for next generation detectors at future QCD Lab. We utilize state-of-the-art multi-gap resistive plate chambers with large modules and long…

Nuclear Experiment · Physics 2019-08-13 Lijuan Ruan

The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by…

Instrumentation and Detectors · Physics 2016-08-09 V. I. Klyukhin , N. Amapane , A. Ball , B. Curé , A. Gaddi , H. Gerwig , M. Mulders , A. Hervé , R. Loveless

This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration