English
Related papers

Related papers: MICROMEGAS chambers for hadronic calorimetry at a …

200 papers

For a hadron calorimeter active element there is considered a gaseous secondary emis-sion detector (150 micron gap, 50 kV/cm). Such one-stage parallel plate chamber must be a radiation hard, fast and simple. A model of such detector has…

Instrumentation and Detectors · Physics 2014-12-11 V. In'shakov , V. Kryshkin , V. Skvortsov

Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time…

A large number of high-energy and heavy-ion experiments successfully used Time Projection Chamber (TPC) as central tracker and particle identification detector. However, the performance requirements on TPC for new high-rate particle…

Instrumentation and Detectors · Physics 2013-02-14 M. Poli Lener , M. Bazzi , G. Corradi , C. Curceanu , A. D'Uffizi , C. Paglia , A. Romero Vidal , E. Sbardella , A. Scordo , D. Tagnani , J. Zmeskal

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions…

Instrumentation and Detectors · Physics 2020-06-09 CMS Muon Group

We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous…

Instrumentation and Detectors · Physics 2025-05-20 Wenming Zhang , Yuanchun Liu , Ke Han , Shaobo Wang , Xiaopeng Zhou , Xunan Guo

Liquid argon time projection chambers have emerged as a competitive technology for detecting solar neutrinos. The SoLAr collaboration was formed to explore argon detectors with pixelated light and charge readout, aiming for high detection…

A novel hadron calorimeter is being developed for future lepton colliding beam detectors. The calorimeter is optimized for the application of Particle Flow Algorithms (PFAs) to the measurement of hadronic jets and features a very finely…

In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC), the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD) were investigated in…

Instrumentation and Detectors · Physics 2015-12-23 Marco Cortesi , Wolfgang Mittig , Daniel Bazin , Saul Beceiro-Novo , John Yurkon , Rim Soussi Tanani , Michael Wolff , Andreas Stolz

A position sensitive thin gap chamber has been developed. The position resolution was measured using the cosmic muons. This paper presents the structure of this detector, position resolution measurement method and results.

Instrumentation and Detectors · Physics 2015-06-17 Yanyan Du , Tongye Xu , Ruobin Shao , Xu Wang , Chengguang Zhu

X-ray calorimetric sample platforms combining specific heat and synchrotron x-ray measurements provide a powerful means to investigate fundamental material properties. Calorimeter cell designs featuring a compact heater and thermometer…

Instrumentation and Detectors · Physics 2026-02-02 U. Patel , H. Zheng , J. L. McChesney , U. Welp , Z. Islam , A. Miceli

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800…

A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at…

Instrumentation and Detectors · Physics 2015-06-03 F. J. Iguaz , E. Ferrer-Ribas , A. Giganon , I. Giomataris

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN…

Instrumentation and Detectors · Physics 2015-06-03 Jonathan Bortfeldt , Otmar Biebel , David Heereman , Ralf Hertenberger

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas…

The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). Here we report on the…

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS,…

Instrumentation and Detectors · Physics 2010-07-02 R. Olivera , V. Peskov , Pietropaolo , P. Picchi

We have developed MICROMEGAS (MICRO MEsh GASeous) detectors for detecting {\alpha} particles emitted from an 241-Am standard source. The voltage applied to the ionization region of the detector is optimized for stable operation at room…

Instrumentation and Detectors · Physics 2016-05-25 Do Yoon Kim , Cheolmin Ham , Jae Won Shin , Tae-Sun Park , Seung-Woo Hong , Samuel Andriamonje , Yacine Kadi , Claudio Tenreiro

We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as…

New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6…

The long-term stability in terms of gain and energy resolution of a prototype triple Gas Electron Multiplier (GEM) detector has been investigated with high rate X-ray irradiation. Premixed Ar/CO2 (80:20) and (90:10) gases have been used for…

Instrumentation and Detectors · Physics 2021-07-05 S Chatterjee , S Roy , A Sen , S Chakraborty , S Das , S K Ghosh , S K Prasad , S Raha , S Biswas