English
Related papers

Related papers: Scintillation Pulse Shape Discrimination in a Two-…

200 papers

Liquid xenon detectors such as XENON10 and XENON100 obtain a significant fraction of their sensitivity to light (<10 GeV) particle dark matter by looking for nuclear recoils of only a few keV, just above the detector threshold. Yet in this…

Instrumentation and Methods for Astrophysics · Physics 2011-01-27 Peter Sorensen

A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the…

Instrumentation and Detectors · Physics 2015-12-09 Bo Wan , Xueying Zhang , Liang Chen , Honglin Ge , Fei Ma , Hongbin Zhang , Yongqin Ju , Yanbin Zhang , Yanyan Li , Xiaowei Xu

A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is described in this paper. Efficient discrimination of alpha and beta…

Instrumentation and Detectors · Physics 2015-05-28 I. Kreslo , I. Badhrees , S. Delaquis , A. Ereditato , S. Janos , M. Messina , U. Moser , B. Rossi , M. Zeller

An 800L liquid xenon scintillation $\gamma$ ray detector is being developed for the MEG experiment which will search for $\mu^+\to\mathrm{e}^+\gamma$ decay at the Paul Scherrer Institut. Absorption of scintillation light of xenon by…

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any…

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…

Astrophysics · Physics 2008-11-26 T. Shutt , C. E. Dahl , J. Kwong , A. Bolozdynya , P. Brusov

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…

XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and…

Pulse shape discriminating scintillator materials in many cases allow the user to identify two basic kinds of pulses arising from two kinds of particles: neutrons and gammas. An uncomplicated solution for building a classifier consists of a…

Instrumentation and Detectors · Physics 2021-02-03 Andrew Glenn , Qi Cheng , Alan D. Kaplan , Ron Wurtz

SuperCDMS is the next phase of the Cryogenic Dark Matter Search experiment, which measures both phonon and charge signals generated by particle recoils within a germanium target mass. Charge signals are employed both in the definition of a…

Instrumentation and Detectors · Physics 2019-08-13 S. A. Hertel , M. Pyle

Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a…

A low pressure time projection chamber for the detection of WIMPs is discussed. Discrimination against Compton electron background in such a device should be very good, and directional information about the recoil atoms would be obtainable.…

Prompt scintillation signals from $^{83m}$Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber.…

A new data analysis method based on physical observables for WIMP dark matter searches with noble liquid Xe dual-phase TPCs is presented. Traditionally, the nuclear recoil energy from a scatter in the liquid target has been estimated by…

Instrumentation and Methods for Astrophysics · Physics 2012-12-24 K. Arisaka , P. Beltrame , C. Ghag , K. Lung , P. R. Scovell

The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and…

Instrumentation and Detectors · Physics 2019-07-03 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , L. Althueser , F. D. Amaro , V. C. Antochi , F. Arneodo , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , A. Elykov , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , L. Grandi , Z. Greene , C. Hasterok , E. Hogenbirk , J. Howlett , M. Iacovacci , R. Itay , F. Joerg , S. Kazama , A. Kish , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , E. López Fune , C. Macolino , J. Mahlstedt , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , J. Masbou , D. Masson , S. Mastroianni , M. Messina , K. Micheneau , K. Miller , A. Molinario , K. Morå , Y. Mosbacher , M. Murra , J. Naganoma , K. Ni , U. Oberlack , K. Odgers , B. Pelssers , F. Piastra , J. Pienaar , V. Pizzella , G. Plante , R. Podviianiuk , H. Qiu , D. Ramírez García , S. Reichard , B. Riedel , A. Rizzo , A. Rocchetti , N. Rupp , J. M. F. dos Santos , G. Sartorelli , N. Šarčević , M. Scheibelhut , S. Schindler , J. Schreiner , D. Schulte , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , E. Shockley , M. Silva , H. Simgen , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , N. Upole , M. Vargas , O. Wack , H. Wang , Z. Wang , Y. Wei , C. Weinheimer , D. Wenz , C. Wittweg , J. Wulf , J. Ye , Y. Zhang , T. Zhu , J. P. Zopounidis

The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that…

Instrumentation and Detectors · Physics 2017-03-08 F. Neves , A. Lindote , A. Morozov , V. Solovov , C. Silva , P. Bras , J. P. Rodrigues , M. I. Lopes

Density fluctuations in the ionised interstellar medium have a profound effect on radio pulsar observations, through angular scattering, intensity scintillations, and small changes in time delays from dispersion. Here we show that it is…

High Energy Astrophysical Phenomena · Physics 2023-04-12 Daniel J. Reardon , William A. Coles

The dual-phase xenon time projection chamber (TPC) is a leading detector technology in rare event searches for dark matter and neutrino physics. The success of this type of detector technology relies on its capability to detect both primary…

Instrumentation and Detectors · Physics 2022-02-16 Yuehuan Wei , Jianyang Qi , Evan Shockley , Haiwen Xu , Kaixuan Ni

Xenon is the target material of choice in several rare event searches. The use of infrared (IR) scintillation light, in addition to the commonly used vacuum ultraviolet (VUV) light, could increase the sensitivity of these experiments.…

Instrumentation and Detectors · Physics 2024-01-18 Robert Hammann , Kai Böse , Luisa Hötzsch , Florian Jörg , Teresa Marrodán Undagoitia
‹ Prev 1 3 4 5 6 7 10 Next ›