In view of a possible application as a charge-particle track readout for an Active-Target Time Projection Chamber (AT-TPC), the operational properties and performances of a hybrid Micro-Pattern Gaseous Detector (MPGD) were investigated in…

Instrumentation and Detectors · Physics 2015-12-23 Marco Cortesi , Wolfgang Mittig , Daniel Bazin , Saul Beceiro-Novo , John Yurkon , Rim Soussi Tanani , Michael Wolff , Andreas Stolz

Mechanisms of charging-up and charging-down of Gas Electron Multiplier (GEM) have been studied. Experimental investigations have been carried out on both dielectric polarization and radiation charging of GEMs. Environmental parameters, such…

Instrumentation and Detectors · Physics 2021-03-24 Vishal Kumar , Sridhar Tripathy , Purba Bhattacharya , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkar

Study of the uniformity of gain, energy resolution and count rate over active area of a triple GEM detector has been performed using a strong Fe55 X-ray source with premixed gas of Argon and CO2 in 70/30 ratio and conventional NIM…

Instrumentation and Detectors · Physics 2019-07-24 S. Chatterjee , S. Chakraborty , S. Roy , S. Biswas , S. Das , S. K. Ghosh , S. K. Prasad , S. Raha

The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…

Instrumentation and Detectors · Physics 2011-10-20 J. Yu , E. Baldelomar , K. Park , S. Park , M. Sosebee , N. Tran , A. P. White

A wire GEM (WGEM) detector with a gas gap between meshes was constructed. The detector provides the amplification 5x10E5 for the gas mixture of Ar +20% CO2 at atmospheric pressure. As compared with well-known GEM detectors produced by…

Instrumentation and Detectors · Physics 2009-11-26 B. M. Ovchinnikov , V. I. Razin , A. I. Reshetin , S. N. Filippov

A technique for measuring high-energy electrons using Si detectors of various thicknesses that are much smaller than the range of the examined electrons is presented. The advantages of the method are discussed on the basis of…

Instrumentation and Detectors · Physics 2024-02-27 Gokul Das H , R. Dubey , K. Czerski , M. Kaczmarski , A. Kowalska , N. Targosz-Sleczkaa , M. Valat

We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they…

Instrumentation and Detectors · Physics 2015-06-26 F. D. Amaro , J. F. C. A. Veloso , A. Breskin , R. Chechik , J. M. F. dos Santos

Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…

Instrumentation and Detectors · Physics 2017-01-20 Tomohisa Ogawa , Yumi Aoki

In this work a set of simulations that aim at the optimization of gaseous detectors for applications in X-ray fluorescence imaging in the energy range of 3 -- 30keV is presented. By studying the statistical distribution of the radiation…

Instrumentation and Detectors · Physics 2024-10-01 Geovane G. A. de Souza , Hugo Natal da Luz , Marco Bregant

We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron…

Instrumentation and Detectors · Physics 2009-06-25 F. D. Amaro , J. F. C. A. Veloso , J. M. F. dos Santos , A. Breskin , R. Chechik , A. Lyashenko

Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a…

The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…

Instrumentation and Detectors · Physics 2015-10-28 Kiadtisak Saenboonruang , Piyakul Kumphiranon , Kittipong Kulasri , Anawat Ritthirong

The characteristic studies of a Single Mask~(SM) triple Gas Electron Multiplier (GEM) detector are carried out using Ar/CO$_2$ gas mixture in 70/30 volume ratio in continuous flow mode. A Fe$^{55}$ X-ray source is used for this work. The…

Instrumentation and Detectors · Physics 2022-11-30 S. Chatterjee , A. Sen , S. Das , S. Biswas

First imaging results in liquid xenon of a Liquid Hole Multiplier (LHM) coupled to a Quad-Silicon Photomultiplier (SiPM) array are presented. Ionization electrons deposited in the noble liquid by 5.5 MeV alpha particles, are collected into…

Instrumentation and Detectors · Physics 2019-02-20 E. Erdal , A. Tesi , D. Vartsky , S. Bressler , L. Arazi , A. Breskin

We have developed and successfully used several innovative designs of detectors with solid photocathodes. The main advantage of these detectors is that rather high gains (>10E4) can be achieved in a single multiplication step. This is…

Instrumentation and Detectors · Physics 2009-11-07 P. Carlson , C. Iacobeaus , T. Francke , B. Lund-Jensen , L. Periale , V. Peskov , I. Rodionov

The bubble-assisted Liquid Hole-Multiplier (LHM) is a recently-introduced detection concept for noble-liquid time projection chambers. In this "local dual-phase" detection element, a gas bubble is supported underneath a perforated electrode…

Instrumentation and Detectors · Physics 2017-03-08 E. Erdal , L. Arazi , M. Rappaport , S. Shchemelinin , D. Vartsky , A. Breskin

We report on recent advances in the operation of bubble-assisted Liquid Hole Multipliers (LHM). By confining a vapor bubble under or adjacent to a perforated electrode immersed in liquid xenon, we could record both radiation-induced…

Instrumentation and Detectors · Physics 2018-12-26 E. Erdal , L. Arazi , A. Tesi , A. Roy , S. Shchemelinin , D. Vartsky , A. Breskin

A study has been carried out to evaluate the performance stability of Gas Electron Multiplier (GEM) chamber prototypes in the laboratory using $^{55}$Fe radiation source with Argon and CO$_2$ gas mixture. This research focuses on the…

Instrumentation and Detectors · Physics 2026-04-10 S. Mandal , S. Gope , S. Das , S. Biswas

Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas…

Instrumentation and Detectors · Physics 2015-06-22 S. Biswas , A. Abuhoza , U. Frankenfeld , J. Hehner , C. J. Schmidt , H. R. Schmidt , M. Traeger , S. Colafranceschi , A. Marinov , A. Sharma