English
Related papers

Related papers: A new high-background-rejection dark matter Ge cry…

200 papers

The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode…

Cosmology and Nongalactic Astrophysics · Physics 2019-08-13 E. Armengaud

The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of…

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400-g heat-and-ionization cryogenic detectors equipped with Inter-Digit electrodes for the rejection of near-surface events. Results from…

High Energy Physics - Experiment · Physics 2011-06-09 Torrento-Coello , A. S

The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and…

The EDELWEISS-II experiment uses cryogenic heat-and-ionization Germanium detectors in order to detect the rare interactions from WIMP dark matter particles of local halo. New-generation detec- tors with an interleaved electrode geometry…

Cosmology and Nongalactic Astrophysics · Physics 2010-12-13 Gilles Gerbier , for EDELWEISS collaboration

The report describes the research program on the development of ultra-low-energy germanium detectors, with emphasis on WIMP dark matter searches. A threshold of 100 eV is achieved with a 20 g detector array, providing a unique probe to the…

High Energy Physics - Experiment · Physics 2008-11-26 H. T. Wong

EDELWEISS is a direct dark matter search using cryogenic germanium heat-ionisation detectors, located in the Modane underground laboratory beneath the Alps. We summarize the final results of EDELWEISS I, which deployed up to almost one kg…

Astrophysics · Physics 2019-08-14 M. LUCA

EDELWEISS is a direct dark matter search experiment situated in the low radioactivity environment of the Modane Underground Laboratory. The experiment uses Ge detectors at very low temperature in order to identify eventual rare nuclear…

Instrumentation and Methods for Astrophysics · Physics 2009-08-04 Véronique Sanglard

Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold,…

The EDELWEISS collaboration searches for light Dark Matter (DM) particles using germanium detectors equipped with a charge and phonon signal readout. Using the Neganov-Trofimov-Luke effect, an rms resolution of 0.53 electron-hole pair was…

The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more…

The EDELWEISS II experiment is devoted to the search for Weakly Interacting Massive Particles (WIMP) that would constitute the Dark Matter halo of our Galaxy. For this purpose, the experiment uses cryogenic germanium detectors, cooled down…

Cosmology and Nongalactic Astrophysics · Physics 2014-11-20 Veronique Sanglard

The use of High Purity Germanium detectors operated in ionization mode at cryogenic temperatures is investigated as an external background mitigation solution for bolometers used in rare-event search experiments. A simple experimental setup…

High Energy Physics - Experiment · Physics 2025-09-05 Chloé Goupy , Stefanos Marnieros , Beatrice Mauri , Claudia Nones , Matthieu Vivier

The Cryogenic Dark Matter search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering of target nuclei. The last analysis with an germanium exposure of 397.8 kg-days resulted in zero…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 T. Bruch

The EDELWEISS collaboration has performed a search for Dark Matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector operated underground at the LSM. A charge resolution of 0.53 electron-hole pairs (RMS) has…

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an…

The EDELWEISS Dark Matter Search uses low-temperature Ge detectors with heat and ionisation read-out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Preliminary results obtained with 320g…

The Edelweiss experiment uses Ge-bolometers with an improved background rejection (interleaved electrode design) to search for WIMP dark matter. The setup is located in the underground laboratory, Laboratoire Souterrain de Modane (LSM,…

Cosmology and Nongalactic Astrophysics · Physics 2019-08-14 V. Y. Kozlov

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are…

‹ Prev 1 2 3 10 Next ›