Related papers: FLASH Beam-Off RF Measurements and Analyses
We present a time-resolved infrared (IR) pump and extreme-ultraviolet (XUV) probe diffraction experiment to investigate ultrafast structural dynamics in colloidal crystals with picosecond resolution. The experiment was performed at the…
During the pulsed operation of the linear accelerator in DCLS (Dalian Coherent Light Source), we found a strong correlation between the klystron modulator's high voltage and the klystron output microwave, with noticeable jitter among…
We report the results of a low-latency beam phase feed-forward system built to stabilize the arrival time of a relativistic electron beam. The system was operated at the Compact Linear Collider (CLIC) Test Facility (CTF3) at CERN where the…
Low frequency high precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to…
For the CLIC two-beam scheme, a high-current, long-pulse drive beam is required for RF power generation. Taking advantage of the 3 GHz klystrons available at the LEP injector once LEP stops, a 180 MeV electron accelerator is being…
We demonstrate Ramsey-Bord\'e (RB) atom interferometry for high performance laser stabilization with fractional frequency instability $<2 \times 10^{-16}$ for timescales between 10 and 1000s. The RB spectroscopy laser interrogates two…
Radiofrequency (RF) systems play a critical role in particle accelerators by enabling the acceleration, manipulation, and diagnosis of charged particle beams. At the heart of many of these systems lies the RF cavity, whose effective design…
We propose a set of experiments in which Ramsey-fringe techniques are tailored to probe transitions originating and terminating on the same ground state level. When pulses of resonant radiation, separated by a time delay $% T, $ interact…
Achieving the highest possible mass resolving power in a multi-reflection time-of-flight mass spectrometer requires very high-stability power supplies. To this end, we have developed a programmable high-voltage power supply that can achieve…
Millimeter wave (mmWave) systems can enable high data rates if the link between the transmitting and receiving radios is configured properly. Fast configuration of mmWave links, however, is challenging due to the use of large antenna arrays…
The NML cryogenic plant cools two individually cryostated superconducting radio frequency (SRF) capture cavities and one prototype ILC cryomodule with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable…
There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system…
Accelerators produce too many signals for a small operations team to monitor in real time. In addition, many of these signals are only interpretable by subject matter experts with years of experience. As a result, changes in accelerator…
When a superconducting radiofrequency cavity is cooled through its critical temperature, ambient magnetic flux can become "frozen in" to the superconductor, resulting in degradation of the quality factor. This is especially problematic in…
We report on the development of a trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and…
In this paper, we conduct wireless channel measurements in indoor corridor scenarios at 2.4, 5 and 6 GHz bands with bandwidth of 320 MHz. The measurement results of channel characteristics at different frequency bands such as average power…
Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity…
We present a laser frequency stabilization system that uses a transfer interferometer to stabilize slave lasers to a reference laser. Our implementation uses off-the-shelf optical components along with microcontroller-based digital…
Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated…
Quantum information processing using atomic qubits requires narrow linewidth lasers with long-term stability for high fidelity coherent manipulation of Rydberg states. In this paper, we report on the construction and characterization of…