Related papers: The KamLAND Full-Volume Calibration System
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector,…
We propose a robust calibration pipeline that optimises the selection of calibration samples for the estimation of calibration parameters that fit the entire scene. We minimise user error by automating the data selection process according…
The energy calibration of calorimeters at collider experiments, such as the ones at the CERN Large Hadron Collider, is crucial for achieving the experiments physics objectives. Standard calibration approaches have limitations that become…
European Spallation Source instruments like the macromolecular diffractometer, NMX, require an excellent neutron detection efficiency, high-rate capabilities, time resolution, and an unprecedented spatial resolution in the order of a few…
The GEM-based neutron detector has flourished in the past decade. However almost all the GEM-based neutron detectors work in the flow-gas mode, and the long-term performances of the detectors may be unstable due to the dynamic changes of…
The SoLid collaboration is currently operating a 1.6 tons neutrino detector near the Belgian BR2 reactor, with main goal the observation of the oscillation of electron antineutrinos to previously undetected flavor states. The highly…
The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…
The development of new phased array systems in radio astronomy, as the low frequency array (LOFAR) and the square kilometre array (SKA), formed of a large number of small and flexible elementary antennas, has led to significant challenges.…
We have developed a luminescence-measurement system for liquid bio/chemiluminescence that can obtain quantitative luminescence spectra as the absolute total number of luminescence photons at each wavelength or photon energy and quantum…
The aim of the Cryogenic wide-Area Light Detectors with Excellent Resolution (CALDER) project is the development of light detectors with active area of $5\times5$ cm$^2$ and noise energy resolution smaller than 20 eV RMS, implementing…
The data from ground based gravitational-wave detectors such as Advanced LIGO and Virgo must be calibrated to convert the digital output of photodetectors into a relative displacement of the test masses in the detectors, producing the…
We present the Aemulus $\nu$ simulations: a suite of 150 $(1.05 h^{-1}\rm Gpc)^3$ $N$-body simulations with a mass resolution of $3.51\times 10^{10} \frac{\Omega_{cb}}{0.3} ~ h^{-1} M_{\odot}$ in a $w\nu$CDM cosmological parameter space.…
Jiangmen Underground Neutrino Observatory (JUNO) is designed to determine the neutrino mass hierarchy using a 20 kton liquid scintillator detector. To calibrate detector boundary effect, the Guide Tube Calibration System (GTCS) has been…
This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile…
The LUX-ZEPLIN experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon. Surrounding the liquid xenon cryostat is an outer detector veto system with the primary aim of…
The Scintillating Bubble Chamber (SBC) Collaboration is designing a new generation of low background, noble liquid bubble chamber experiments with sub-keV nuclear recoil threshold. These experiments combine the electronic recoil blindness…
An electron accelerator in the 100 MeV range, similar to the one used at BNL's Accelerator test Facility, for example, would have some advantages as a calibration tool for water cerenkov or Liquid Argon neutrino detectors. We describe a…
We present the results of a time-coincident event search for low-energy electron antineutrinos in the KamLAND detector with gamma-ray bursts from the Gamma-ray Coordinates Network and Fermi Gamma-ray Burst Monitor. Using a variable…
We present a simulation-based study of a compact directional neutron detector composed of liquid scintillator, Cesium Iodide, with boron carbide (B4C) moderation, and silicon photomultipliers (SiPMs). Using GEANT4, we explored multiple…
Context: XMM-Newton was launched on 10 December 1999 and has been operational since early 2000. One of the instruments onboard XMM-Newton is the reflection grating spectrometer (RGS). Two identical RGS instruments are available, with each…