Related papers: Tau-pair Performance in ILD detectors
Tau-pair process has been analyzed in the ILD detector model as a benchmark process for LoI. Results of background rejection, forward-backward asymmetry and polarization measurements are obtained with full detector simulation.
The process $e^- e^+ \to \tau^- \tau^+$ is of particular interest because the tau lepton polarisation can be reconstructed, allowing its chiral nature to be probed. This note reports on a study of the reconstruction of the di-tau final…
Measurement of the tau lepton polarization in \eett\ is an important electro-weak measurement at ILC and other future electron-positron colliders. In this paper we discuss several methods to extract polarimeter information for \eett\ events…
In many SUSY models the first SUSY signal in the proposed International Linear Collider is expected to come from the pair production of $\tilde\tau_1$, followed by its decay into $\tau$+LSP. We study a simple and robust method of measuring…
The QED processes e^+ e^- -> e^+ e^- \mu^+ \mu^- and e^+ e^- -> e^+ e^- \tau^+ \tau^- are studied with the L3 detector at LEP using an untagged data sample collected at centre-of-mass energies 161 GeV < sqrt{s} < 209 GeV. The tau-pairs are…
The ILC accelerator parameters and detector concepts are still under discussion in the world-wide community. As will be shown, the performance of the BeamCal, the calorimeter in the very forward area of the ILC detector, is very sensitive…
We present a novel method for the reconstruction of events containing pairs of hadronically decaying tau leptons at collider experiments. This method relies on accurate knowledge of the tau production vertex and precise measurement of its…
Measurements of the tau lepton polarization and forward-backward polarization asymmetry near the Z resonance using the OPAL detector are described. The measurements are based on analyses of tau -> e nu_e nu_tau, tau -> mu nu_mu nu_tau, tau…
A study of events containing two tau leptons with high transverse momentum has been performed with the ZEUS detector at HERA, using a data sample corresponding to an integrated luminosity of 0.33 fb-1. The tau candidates were identified…
We show how the sum of the two average tau polarisations in the decay chain chi20 -> stau1 tau -> tau tau chi10 in minimal supersymmetry with conserved R-parity can be measured at the LHC. This is accomplished by exploiting the polarisation…
This thesis describes a new a measurement of the tau lepton polarization and its forward-backward asymmetry at the Z resonance using the OPAL detector. This measurement is based on analyses of the tau->electron, muon and pion (Kaon) decays…
The report reviews the measurements of the tau lepton parameters. The tau mass measurements at the KEDR detector as well as at the B-factories are considered in more details. The present limitations on the lepton universality are discussed.
We present the first results on tau physics using polarized beams. These include measurements of the $\tau$ Michel parameters $\xi$ and $\xi\delta$ and the $\tau$ neutrino helicity $h_\nu$. The measurements were performed using the SLD…
We consider the production of tau pairs by electron-positron colliding beams at the maximum cross section near the threshold. At this energy tau pairs are produced mostly in the s-wave which implies that the spin of the tau pairs are almost…
The BABAR collaboration has demonstrated the first application of the new Tau Polarimetry technique. This polarimetry technique exploits the kinematic coupling of $\tau$ decay products to the spin states of the $\tau$ and initial state…
A first measurement of the average polarisation P_tau of tau leptons produced in e+e- annihilation at energies significantly above the Z resonance is presented. The polarisation is determined from the kinematic spectra of tau hadronic…
Receiver operating characteristic (ROC) analysis is widely used for evaluating diagnostic systems. Recent studies have shown that estimating an area under ROC curve (AUC) with standard cross-validation methods suffers from a large bias. The…
The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design…
The performance of the ILD detector at the ILC for the analysis of $\mu$ and $\tau$ channels at the SUSY benchmark-point SPS1a' has been studied with full detector simulation. It is concluded that if 500 fb$^{-1}$ is delivered to the…
The pair monitor is a beam profile monitor at interaction point (IP) for the international linear collider (ILC). We have designed and developed the pair monitor as a silicon pixel sensor which is located at about 400 cm from IP. As the…