Related papers: Compton Cherenkov Detector Development for ILC Pol…
The DEPFET Collaboration pursues the development of a high resolution pixel vertex detector for future colliders (like ILC), based on the integration of amplifying transistors into a fully depleted bulk. In August 2008, six DEPFET…
A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…
Top quark production in the process $e^+e^- \rightarrow t\bar{t}$ at a future linear electron positron collider with polarised beams is a powerful tool to determine indirectly the scale of new physics. The presented study, based on a…
To achieve the extremely high luminosity for colliding electron-positron beams at the future International Linear Collider (ILC) an undulator-based source with about 230 meters helical undulator and a thin titanium-alloy target rim rotated…
We have developed a correlation radiometer at 33 GHz devoted to the search for residual polarization of the Cosmic Microwave Background (CMB). The two instruments`s outputs are linear combination of two Stokes Parameters (Q and U or U and…
The investigation of $e \gamma \to \nu W$ process is crucial for a possible high energy $e \gamma$ or $\gamma \gamma$ collider since it offers the possibility for both new physics discovery and precision measurements. The polarization of…
Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle…
The polarization of final-state photons is a critical observable for probing the fundamental mechanisms of particle and nuclear interactions, providing insights into spin and parity structure that are inaccessible through cross-section…
We present recent improvements in polarization analysis with the INTEGRAL SPI data. The SPI detector plane consists of 19 independent Ge crystals and can operate as a polarimeter. The anisotropy characteristics of Compton diffusions can…
$\gamma$ rays are emitted by cosmic sources by non-thermal processes that yield either non-polarized photons, such as those from $\pi^0$ decay in hadronic interactions, or linearly polarized photons from synchrotron radiation and the…
Quantum entanglement between gamma-ray photons emitted following electron-positron annihilation is expected to be maximal and may be characterized via non-classical polarization correlations. However, this is difficult to verify…
A novel polarimeter based on the asymmetry in the spacial distribution of synchrotron radiation will make for a fine addition to the existing M{\o}ller and Compton polarimeters. The spin light polarimeter consists of a set of wiggler magnet…
A future linear collider such as TESLA may be able to run on the Z0 resonance with very high luminosity and polarised electron and positron beams. The possibilities of measuring electroweak quantities with high precision are investigated.…
A novel method for the direct measurement of the degree of polarization is described. It is one of the first practical implementations of a coherent quantum measurement, the projection on the singlet state. Our first results demonstrate the…
The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD…
We present the design and performance of a non-imaging concentrator for use in broad-band polarimetry at millimeter through submillimeter wavelengths. A rectangular geometry preserves the input polarization state as the concentrator couples…
The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed…
A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…
To achieve the physics goals of future Linear Colliders, it is important that electron and positron beams are polarized. The positron source planned for the International Linear Collider (ILC) is based on a helical undulator system and can…
It has been recently proposed (Boggs, Nucl. Instr. and Meth. A 503 (2003) 562), to use polarization of Compton scattered gamma-rays to improve the imaging performance of Compton telescopes. Building upon that work, we detected the…