Related papers: 2E1 Ar17+ decay and conventional radioactive sourc…
An improved method of energy calibration of position-sensitive silicon detector is presented. Instead of the parabolic function used in traditional method, a new function describing the relation of position and energy is introduced and…
Results obtained with a new very compact detector for imaging with a matrix of Leak Microstructures (LM)are reported. Spatial linearity and spatial resolution obtained by scanning as well as the detection of alpha particles with 100%…
In this work, two particular properties of the position-sensitive, thick silicon detectors (known as the "E" detectors) in the High Resolution Array (HiRA) are investigated: the thickness of the dead layer on the front of the detector, and…
A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated…
The hyperspectral X-ray imaging has been long sought in various fields from material analysis to medical diagnosis. Here we propose a new semiconductor detector structure to realize energy-resolved imaging at potentially low cost. The…
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…
Photonic quantum technologies such as effective quantum communication require room temperature (RT) operating single- or few- photon sensors with high external quantum efficiency (EQE) at 1550 nm wavelength. The leading class of devices in…
The worldwide need to replace 3He for the neutron detection has triggered R&D on new technologies and methods. A promising one is based on commercial solid state silicon detectors coupled with thin neutron converter layers containing 6Li.…
Single-electron detectors are a key component of electron microscopes and advanced electron optics experiments. We present a YAG:Ce scintillator-based single-electron detector with a spatial resolution of 1 micrometer at an electron energy…
Many of the interesting physics processes to be measured at the LHC have a signature involving one or more isolated electrons. The electron reconstruction and identification efficiencies of the ATLAS detector at the LHC have been evaluated…
Efficiently distinguishing photon numbers is a crucial yet challenging technology for various quantum information and quantum metrology applications. While superconducting transition edge sensors offer good photon-number-resolving (PNR)…
There exists an enormous interest for the study of very high energy domain in particle physics, both theoretically and experimentally, in the aim to construct a general theory of the fundamental constituents of matter and of their…
We have investigated the depletion voltage changes, the leakage current increase and the charge collection efficiency of a silicon microstrip detector identical to those used in the inner layers of the BaBar Silicon Vertex Tracker (SVT)…
The integrated optical circuit is a promising architecture for the realization of complex quantum optical states and information networks. One element that is required for many of these applications is a high-efficiency photon detector…
We have measured proton and alpha-particle branching ratios of excited states in 19Ne formed using the 19F(3He,t) reaction at a beam energy of 25 MeV. These ratios have a large impact on the astrophysical reaction rates of 15O(alpha,gamma),…
Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond…
The efficiency of the photon identification criteria in the ATLAS detector is measured using 36.1 fb$^{-1}$ to 36.7 fb$^{-1}$ of $pp$ collision data at $\sqrt{s}$ = 13 TeV collected in 2015 and 2016. The efficiencies are measured separately…
Characterization of a hybrid ${\it telescope}$ with gas transmission detector ($\Delta$E) and a solid-state stop detector (E) has been fabricated for detection of low energy $\alpha$ particles between 5 to 1 MeV. The detector is developed…
The algorithms used by the ATLAS Collaboration to reconstruct and identify prompt photons are described. Measurements of the photon identification efficiencies are reported, using 4.9 fb$^{-1}$ of pp collision data collected at the LHC at…
Detailed measurements of the electron performance of the ATLAS detector at the LHC are reported, using decays of the Z, W and J/psi particles. Data collected in 2010 at sqrt(s)=7 TeV are used, corresponding to an integrated luminosity of…