Related papers: Non-destructive measurement of the transition prob…
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…
We present and implement a non-destructive detection scheme for the transition probability readout of an optical lattice clock. The scheme relies on a differential heterodyne measurement of the dispersive properties of lattice-trapped atoms…
Optical lattice clocks based on the narrow (5s2)1S0 - (5s5p)3P0 transition in neutral strontium (Sr) are among the most precise and accurate measurement devices in existence. Although this transition is completely forbidden by selection…
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with a fractional accuracy of 2.6 10^{-15}, a value that is…
With ultracold $^{87}$Sr confined in a magic wavelength optical lattice, we present the most precise study (2.8 Hz statistical uncertainty) to-date of the $^1S_0$ - $^3P_0$ optical clock transition with a detailed analysis of systematic…
The absolute frequency of the 1S0-3P0 clock transition of 87Sr has been measured to be 429 228 004 229 873.65 (37) Hz using lattice-confined atoms, where the fractional uncertainty of 8.6x10-16 represents one of the most accurate…
We report the first accuracy evaluation of an optical lattice clock based on the 1S0 - 3P0 transition of an alkaline earth boson, namely 88Sr atoms. This transition has been enabled using a static coupling magnetic field. The clock…
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been…
Existing optical lattice clocks demonstrate a high level of performance, but they remain complex experimental devices. In order to address a wider range of applications including those requiring transportable devices, it will be necessary…
We demonstrate a one-dimensional optical lattice clock with a spin-polarized fermionic isotope designed to realize a collision-shift-free atomic clock with neutral atom ensembles. To reduce systematic uncertainties, we developed both Zeeman…
We present a measurement of the absolute frequency of the 5s$^2$ $^1$S$_0$ to 5s5p $^3$P$_0$ transition in $^{87}$Sr, which is a secondary representation of the SI second. We describe the optical lattice clock apparatus used for the…
We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise…
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and…
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the SI second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation…
We explore the limits of atomic coherence and measurement precision in a 87Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice…
We observe two-body loss of ${}^3P_0$ ${}^{87}$Sr atoms trapped in a one-dimensional optical lattice. We measure loss rate coefficients for atomic samples between 1 and 6 $\mu$K that are prepared either in a single nuclear-spin-sublevel or…
We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved…
We report on the isotope shift between ${}^{88}$Sr and ${}^{87}$Sr on the ${}^1S_0 - {}^3P_0$ clock transitions. The interleaved operation of an optical lattice clock with two isotopes allows the canceling out of common perturbations, such…
We report a stability below $7\times 10{}^{-17}$ of two independent optical lattice clocks operating with bosonic ${}^{88}$Sr isotope. The value (429228066418008.3(1.9)${}_{syst}$(0.9)${}_{stat}$~Hz) of the absolute frequency of the…
We report an optical lattice clock with a total systematic uncertainty of $8.1 \times 10^{-19}$ in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultra-narrow…