English
Related papers

Related papers: A demonstrator for bolometric interferometry

200 papers

Detection of B-mode polarization of the cosmic microwave background (CMB) radiation is one of the frontiers of observational cosmology. Because they are an order of magnitude fainter than E-modes, it is quite a challenge to detect B-modes.…

Cosmology and Nongalactic Astrophysics · Physics 2013-01-23 Ata Karakci , P. M. Sutter , Le Zhang , Emory F. Bunn , Andrei Korotkov , Peter Timbie , Gregory S. Tucker , Benjamin D. Wandelt

We demonstrate metamaterial metal-based bolometers, which take advantage of resonant absorption in that a spectral and/or polarization filter can be built into the bolometer. Our proof-of-principle gold-nanostructure-based devices operate…

Bolometric experiments searching for rare events usually require an extremely low radioactive background to prevent spurious signals from mimicking those of interest, spoiling the sensitivity of the apparatus. In such contexts, radioactive…

Instrumentation and Detectors · Physics 2018-03-28 P. Carniti , L. Cassina , A. Giachero , C. Gotti , G. Pessina

We describe the development of a bolometric receiver designed to measure the arcminute-scale polarization of the cosmic microwave background (CMB). The Polatron will be mounted at the Cassegrain focus of the 5.5 m telescope at the Owens…

A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of…

Instrumentation and Methods for Astrophysics · Physics 2022-04-27 M. Piat , G. Stankowiak , E. S. Battistelli , P. de Bernardis , G. D Alessandro , M. De Petris , L. Grandsire , J. -Ch. Hamilton , T. D. Hoang , S. Marnieros , S. Masi , A. Mennella , L. Mousset , C. O Sullivan , D. Prele , A. Tartari , J. -P. Thermeau , S. A. Torchinsky , F. Voisin , M. Zannoni , P. Ade , J. G. Alberro , A. Almela , G. Amico , L. H. Arnaldi , D. Auguste , J. Aumont , S. Azzoni , S. Banfi , B. Belier , A. Bau , D. Bennett , L. Berge , J. -Ph. Bernard , M. Bersanelli , M. -A. Bigot-Sazy , J. Bonaparte , J. Bonis , E. Bunn , D. Burke , D. Buzi , F. Cavaliere , P. Chanial , C. Chapron , R. Charlassier , A. C. Cobos Cerutti , F. Columbro , A. Coppolecchia , G. De Gasperis , M. De Leo , S. Dheilly , C. Duca , L. Dumoulin , A. Etchegoyen , A. Fasciszewski , L. P. Ferreyro , D. Fracchia , C. Franceschet , M. M. Gamboa Lerena , K. M. Ganga , B. Garcia , M. E. Garcia Redondo , M. Gaspard , D. Gayer , M. Gervasi , M. Giard , V. Gilles , Y. Giraud-Heraud , M. Gomez Berisson , M. Gonzalez , M. Gradziel , M. R. Hampel , D. Harari , S. Henrot-Versille , F. Incardona , E. Jules , J. Kaplan , C. Kristukat , L. Lamagna , S. Loucatos , T. Louis , B. Maffei , W. Marty , A. Mattei , A. May , M. McCulloch , L. Mele , D. Melo , L. Montier , L. M. Mundo , J. A. Murphy , J. D. Murphy , F. Nati , E. Olivieri , C. Oriol , A. Paiella , F. Pajot , A. Passerini , H. Pastoriza , A. Pelosi , C. Perbost , M. Perciballi , F. Pezzotta , F. Piacentini , L. Piccirillo , G. Pisano , M. Platino , G. Polenta , R. Puddu , D. Rambaud , E. Rasztocky , P. Ringegni , G. E. Romero , J. M. Salum , A. Schillaci , C. G. Scoccola , S. Scully , S. Spinelli , M. Stolpovskiy , A. D. Supanitsky , P. Timbie , M. Tomasi , C. Tucker , G. Tucker , D. Vigano , N. Vittorio , F. Wicek , M. Wright , A. Zullo

The sensitivity of interferometers with linear polarizers to the CMB E and B mode are variant under the rotation of the polarizer frame, while interferometer with circular polarizers are equally sensitive to E and B mode. We present…

Astrophysics · Physics 2009-04-06 Jaiseung Kim

The Infra-Red Video Bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of LOSs within a large field of view (FOV). Recently validated in MAST-U, it offers a high spatial…

Plasma Physics · Physics 2025-01-23 Fabio Federici , Jack J. Lovell , G. A. Wurden , Byron J. Peterson , Kiyofumi Mukai

We have developed a completely lithographic antenna-coupled bolometer for CMB polarimetry. The necessary components of a millimeter wave radiometer -- a beam forming element, a band defining filter, and the TES detectors -- are fabricated…

We are developing multi-chroic antenna-coupled TES detectors for CMB polarimetry. Multi-chroic detectors increase the mapping speed per focal plane area and provide greater discrimination of polarized galactic foregrounds with no increase…

We propose an innovative demodulation scheme for coherent detectors used in cosmic microwave background polarization experiments. Removal of non-white noise, e.g., narrow-band noise, in detectors is one of the key requirements for the…

Instrumentation and Methods for Astrophysics · Physics 2012-05-22 K. Ishidoshiro , Y. Chinone , M. Hasegawa , M. Hazumi , M. Nagai , O. Tajima

The growing use of ultrashort laser pulses exhibiting time-varying polarization (vector pulses) demands simple and robust characterization techniques capable to perform measurements in a broad range of experimental and environmental…

Optics · Physics 2020-11-04 Benjamín Alonso , Íñigo J. Sola

We show measurements of thermal kinetic inductance detectors (TKID) intended for millimeter wave cosmology in the 200-300 GHz atmospheric window. The TKID is a type of bolometer which uses the kinetic inductance of a superconducting…

Instrumentation and Methods for Astrophysics · Physics 2018-08-01 Bryan A. Steinbach , James J. Bock , Hien T. Nguyen , Roger C. O'Brient , Anthony D. Turner

BICEP1 is a millimeter-wavelength telescope designed specifically to measure the inflationary B-mode polarization of the Cosmic Microwave Background (CMB) at degree angular scales. We present results from an analysis of the data acquired…

The balloon-borne very long baseline interferometry (VLBI) experiment is a technical feasibility study for performing radio interferometry in the stratosphere. The flight model has been developed. A balloon-borne VLBI station will be…

The IR response of a backside illuminated type Yttrium Barium Copper Oxide (YBCO) transition-edge bolometer (TEB) in a free-membrane configuration is measured and analyzed. The analysis is based on a comprehensive equivalent circuit model…

Superconductivity · Physics 2022-08-30 Roya Mohajeri , Seyed Iman Mirzaei , Mehdi Fardmanesh

Matter-wave interference experiments enable us to study matter at its most basic, quantum level and form the basis of high-precision sensors for applications such as inertial and gravitational field sensing. Success in both of these…

We investigate how the temporal coherence interference properties of light in a Michelson-Morley interferometer (MMI), using only a single-photon detector, can be understood in a quantum-optics framework in a straightforward and pedagogical…

Quantum Physics · Physics 2011-03-03 O. Langangen , B. -S. Skagerstam , A. Vaskinn

Wafer-level testing is an important step for process and quality control of electronic chips in integrated circuit (IC) manufacturing which occurs before packaging. The process of wafer probing in its conventional contacting schemes,…

Optics · Physics 2024-02-29 Maryam Sadat Amiri Naeini , Pierre Berini

The Laser Interferometer Space Antenna (LISA) is being designed to detect and study in detail gravitational waves from sources throughout the Universe such as massive black hole binaries. The conceptual formulation of the LISA space-borne…

General Relativity and Quantum Cosmology · Physics 2014-11-17 Scott E Pollack , Robin Tuck Stebbins