Related papers: A TPC with Triple-GEM Gas Amplification and TimePi…
In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a…
The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite projected angles with respect to the…
A new technique for ion identification in Accelerator Mass Spectrometry (AMS) has been proposed by measuring the ion track ranges using a low-pressure TPC. As a proof of principle, a low-pressure TPC with charge readout using a THGEM…
ALICE, one of the experiments at the Large Hadron Collider (CERN), is undergoing ambitious upgrades during the ongoing second long shutdown (LS2). The main goal of this project is to access rare events and previously inaccessible physics…
Test beam facilities are essential to study the response of novel detectors to particles. At the DESY II Test Beam facility, users can test their detectors with an electron beam with a momentum from 1-6 GeV. To track the beam particles,…
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…
A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active…
Two cylindrical forward TPC detectors are described which were constructed to extend the phase space coverage of the STAR experiment to the region 2.5 < |\eta| < 4.0. For optimal use of the available space and in order to cope with the high…
Background: we develop the concept of a Micromegas (MICRO-MEsh GAseous Structure) readout plane with an additional GEM (Gas Electron Multiplier) preamplification stage placed a few mm above it, to increase the maximum effective gain of the…
Future measurements of the flavor-separated spin structure of the proton via parity-violating W boson production at RHIC require an upgrade of the forward tracking system of the STAR detector. This upgrade will allow the reconstruction of…
The triple GEM detector is a micropattern gas detector which consists of a primary ionisation gap and three consecutive gas electron multiplier (GEM) foils. A printed circuit board with readout strips detects the current induced by the…
The sPHENIX detector to be installed at RHIC in 2022 is designed to precisely measure jets, jet correlations, and dilepton pairs in heavy-ion collisions. With these measurements in mind, sPHENIX will employ a compact TPC covering 20cm < r <…
Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC.…
Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and energy simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by…
The TT-PET collaboration is developing a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on…
The main purpose of this work is to study the performance of the APV25 and VMM3a readout chips with regards to using them in the front-end readout system of a Triple-GEM detector. For the APV25, the Signal-to-Noise Ratio (SNR) was estimated…
Development of readout electronics for Time Projection Chamber for a Linear Collider is ongoing under stringent requirements on high channel density, lowest possible power consumption and small material budget. In the studied TPC readout…
The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X-Y-U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using…
The Gas Electron Multiplier (GEM) detector is one of promising particle and radiation detectors that has been improved greatly from previous gas detectors. The improvement includes better spatial resolutions, higher detection rate…