Related papers: Development of Pair Monitor
At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the…
At the International Linear Collider (ILC), measurement of the beam profile at the interaction point (IP) is a key issue to achieve high luminosity. We studied the beam size measurement by combination of Pair Monitor and BeamCal. We…
We fabricated a readout ASIC with the fully depleted silicon-on-insulator (FD-SOI) technology for the pair-monitor. The pair-monitor is a silicon pixel device that measures the beam profile of the international linear collider. It utilizes…
We develop the vertex detector for the international linear collider (ILC) using the FPCCD (Fine Pixel CCD), whose pixel size is 5 x 5 um2. Together with the FPCCD sensor, a prototype of the readout ASIC was developed in 2008. The readout…
One of candidates for the International Linear Collider(ILC)'s vertex detector is the Fine Pixel CCD (FPCCD) with a pixel size of 5 \times 5 (\mum^2). Sensor and readout systems are currently being studied and prototypes have been…
The ILD concept, one of two proposed detector concepts for the planned International Linear Collider (ILC), foresees a Time Projection Chamber (TPC) as the main tracking detector. The LCTPC (Linear Collider TPC) collaboration pursues R&D to…
The SiLC - Silicon for the Linear Collider - collaboration aims to develop silicon detector technology for tracking in the international linear collider experiments. The R & D programme involves a substantial effort in simulation of the…
The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs…
We have developed a silicon pixel detector to enhance the physics capabilities of the PHENIX experiment. This detector, consisting of two layers of sensors, will be installed around the beam pipe at the collision point and covers a…
The International Linear Collider (ILC) is a project of an electron-positron (e+e-) linear collider with the centre-of-mass energy of 200-500 GeV. Monolithic Active Pixel Sensors (MAPS) are one of the proposed silicon pixel detector…
A high-resolution, intratrain position feedback system has been developed to achieve and maintain collisions at the proposed future electron-positron International Linear Collider (ILC). A prototype has been commissioned and tested with a…
CMOS Pixel Sensors are making steady progress towards the specifications of the ILD vertex detector. Recent developments are summarised, which show that these devices are close to comply with all major requirements, in particular the…
The R&D Collaboration SiLC (Silicon tracking for Linear Colliders) is based on generic R&D aiming to develop the next generation of large Silicon tracking systems for the Linear collider experiments; it serves all three ILC detector…
Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
The beams at the ILC produce electron positron pairs due to beam-beam interactions. This note presents for the first time a study of these processes in a detailed simulation, which shows that these pair background particles appear at angles…
Significant progress has been made to develop silicon pixel technologies for use in the vertex and tracker regions of the proposed Compact Linear Collider (CLIC) detector design. The electron-positron collisions generated by this linear…
The nano-meter beam size in future linear colliders requires very high resolution beam position monitor since higher resolution allows more accurate position measurement in the interaction point. We developed and tested a low-Q C-band beam…
The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…
CMOS sensors were successfully implemented in the STAR tracker [1]. LHC experiments have shown that efficient b tagging, reconstruction of displaced vertices and identification of disappearing tracks are necessary. An improved vertex…