Related papers: Development of Readout ASIC for FPCCD Vertex Detec…
Silicon sensors with high time resolution can help particle identification in the International Linear Collider (ILC). We are studying Low Gain Avalanche Diodes (LGADs) as a high timing resolution sensor. As a step to develop LGADs, we are…
The upgraded Inner Tracking System (ITS2) of the ALICE experiment at the CERN Large Hadron Collider is based on Monolithic Active Pixel Sensors (MAPS). With a sensitive area of about 10 $m^2$ and 12.5 billion pixels, ITS2 represents the…
Detectors based on pixels with timing capabilities are gaining increasing importance in the last years. Next-to-come high-energy physics experiments at colliders requires the use of time information in tracking, due to the increasing levels…
We fabricated a readout ASIC with the fully depleted silicon-on-insulator (FD-SOI) technology for the pair-monitor. The pair-monitor is a silicon pixel device that measures the beam profile of the international linear collider. It utilizes…
Low-Gain Avalanche Diode (LGAD) sensor is one of candidate sensors for the tracker at future hadron collider experiments. To use this sensor as a tracking detector, AC-LGAD sensor is being developed which has both timing and spatial…
Samples of the monolithic silicon pixel ASIC prototype produced in 2022 within the framework of the Horizon 2020 MONOLITH ERC Advanced project were irradiated with 70 MeV protons up to a fluence of 1 x 1016 neq/cm2, and then tested using a…
A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National…
Silicon photo-multipliers (SiPM) have been replacing traditional photomultiplier tubes in most light sensing applications. However, when large detection surface coverage is needed, photomultipliers (PMTs) are still the preferred choice. The…
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scattering events with a precision better than 10-3 and a low polar…
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low…
Current, state-of-the-art CCDs are close to being able to deliver all key performance figures for future strategic X-ray missions except for the required frame rates. Our Stanford group is seeking to close this technology gap through a…
The ALICE Collaboration will undertake a major upgrade of the detector apparatus during the second LHC Long Shutdown LS2 (2019-2020) in view of the Runs 3 and 4 (2021-2029). The objective of the upgrade is two-fold: i) an improvement of the…
The ATLAS Forward Physics (AFP) project plans to install 3D silicon pixel detectors about 210 m away from the interaction point and very close to the beamline (2-3 mm). This implies the need of slim edges of about 100-200 $\mu$m width for…
X-ray Charge Coupled Devices (CCDs) have been the workhorse for soft X-ray astronomical instruments for the past quarter century. They provide broad energy response, extremely low electronic read noise, and good energy resolution in soft…
We have been developing a serializer application-specific integrated circuit (ASIC) based on a commercial 0.25-{\mu}m silicon-on-sapphire (SOS) CMOS technology for the ATLAS liquid argon calorimeter front-end electronics upgrade. The first…
The Compact Linear Collider CLIC is designed to deliver e+e- collisions at a center of mass energy of up to 3 TeV. The detector systems at this collider have to provide highly efficient tracking and excellent jet energy resolution and…
A prototype of the CMOS pixel sensor named SUPIX-1 has been fabricated and tested in order to investigate the feasibility of a pixelated tracker for a proposed Higgs factory, namely, the Circular Electron-Positron Collider (CEPC). The…
The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts for the International Linear Collider. SKIROC2 is an ASIC…
The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to…
Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read…