Related papers: Pulse Shape Analysis with a Broad-Energy Germanium…
The GERmanium Detector Array, GERDA, is designed for the search for ``neutrinoless double beta decay'' (0-nu-2-beta) with germanium detectors enriched in Ge76. An 18-fold segmented prototype detector for GERDA Phase II was exposed to an…
The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground laboratory (LNGS) of INFN is searching for neutrinoless double-beta ($0\nu\beta\beta$) decay of $^{76}$Ge. The technological challenge of GERDA is to operate in a…
The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce…
Various methods of identification of single events in the HPGe detector are compared on the basis of a program especially designed to simulate pulse shape in a semi-conductor germanium detector. Capabilities of three following methods are…
The ultralow detection threshold, ultralow intrinsic background, and excellent energy resolution of p-type point-contact germanium detector are important for rare-event searches, in particular for the detection of direct dark matter…
The GERmanium Detector Array (GERDA) is a low background experiment located at the Laboratori Nazionali del Gran Sasso in Italy, which searches for neutrinoless double beta decay of $^{76}$Ge into $^{76}$Se+2e$^-$. GERDA has been conceived…
P-type point contact (PPC) germanium detectors are used in rare event and low-background searches, including neutrinoless double beta (0vbb) decay, low-energy nuclear recoils, and coherent elastic neutrino-nucleus scattering. The detectors…
Compton scattering is one of the dominant interaction processes in germanium for photons with an energy of around two MeV. If a photon scatters only once inside a germanium detector, the resulting event contains only one electron which…
Pulse shape analysis of germanium gamma-ray spectrometer signals can yield information on the radial position of individual gamma-ray interactions within the germanium crystal. A parametric pulse shape analysis based on calculation of…
The p-type point-contact germanium detectors are novel techniques offering kg-scale radiation sensors with sub-keV sensitivities. They have been used for light Dark Matter WIMPs searches and may have potential applications in neutrino…
Among the detectors used for rare event searches, such as neutrinoless Double Beta Decay (0$\nu$DBD) and Dark Matter experiments, bolometers are very promising because of their favorable properties (excellent energy resolution, high…
Experiments to search for neutrinoless double-beta (0{\nu}\b{eta}\b{eta}) decay of 76Ge using a high-purity germanium (HPGe) detector rely heavily on background suppression technologies to enhance their sensitivities. In this work, we…
Low temperature detectors are nowadays a technology widely used for rare events studies, such as the search for dark matter candidates and neutrino-less double beta decay. The convolution of the thermal and electrical response of these…
The performance of a 630g commercial broad energy germanium (BEGe) detector has been systematically investigated. Energy resolution, linearity, stability vs. high-voltage (HV) bias, thickness and uniformity of dead layers have been measured…
Point-contact p-type high-purity germanium detectors (PPC HPGe) are particularly suited for detection of sub-keV nuclear recoils from coherent elastic scattering of neutrinos or light dark matter particles. While these particles are…
We report on the characterization of two inverted coaxial Ge detectors in the context of being employed in future $^{76}$Ge neutrinoless double beta ($0\nu\beta\beta$) decay experiments. It is an advantage that such detectors can be…
The Standard Model of particle physics cannot explain the dominance of matter over anti-matter in our Universe. In many model extensions this is a very natural consequence of neutrinos being their own anti-particles (Majorana particles)…
High Purity germanium point-contact detectors have low energy thresholds and excellent energy resolution over a wide energy range, and are thus widely used in nuclear and particle physics. In rare event searches, such as neutrinoless double…
We report in this paper the proofs that the pulse shape analysis can be used in some bolometers to identify the nature of the interacting particle. Indeed, while detailed analyses of the signal time development in purely thermal detectors…
The p-type point-contact germanium detectors have been adopted for light dark matter WIMP searches and the studies of low energy neutrino physics. These detectors exhibit anomalous behavior to events located at the surface layer. The…