Related papers: Alternative Data Reduction Procedures for UVES: Wa…
This paper studies sensor calibration in spectral estimation where the true frequencies are located on a continuous domain. We consider a uniform array of sensors that collects measurements whose spectrum is composed of a finite number of…
In survey sampling, calibration is a very popular tool used to make total estimators consistent with known totals of auxiliary variables and to reduce variance. When the number of auxiliary variables is large, calibration on all the…
Rather than using an adaptive optics (AO) system to correct a telescope s entire pupil, it can instead be used to more finely correct a smaller sub-aperture. Indeed, existing AO systems can be used to correct a sub-aperture 1/3 to 1/2 the…
We report a method of correcting a near-infrared (0.90-1.35 $\mu$m) high-resolution ($\lambda/\Delta\lambda\sim28,000$) spectrum for telluric absorption using the corresponding spectrum of a telluric standard star. The proposed method uses…
Using the HiVIS spectropolarimeter built for the Haleakala 3.7m AEOS telescope in Hawaii, we are collecting a large number of high precision spectropolarimetrc observations of stars. In order to precisely measure very small polarization…
We describe a new method to calibrate the relative flux levels in spectra from the HIRES echelle spectrograph on the Keck-I telescope. Standard data reduction techniques that transfer the instrument response between HIRES integrations leave…
We present flame, a pipeline for reducing spectroscopic observations obtained with multi-slit near-infrared and optical instruments. Because of its flexible design, flame can be easily applied to data obtained with a wide variety of…
This paper describes the VIS Processing Function (VIS PF) of the Euclid ground segment pipeline, which processes and calibrates raw data from the VIS camera. We present the algorithms used in each processing element, along with a…
Wavefront estimation is an essential component of adaptive optics where the goal is to recover the underlying phase from its Fourier magnitude. While this may sound identical to classical phase retrieval, wavefront estimation faces more…
The fine calibration of the ISO-SWS detectors (Infrared Space Observatory - Short Wavelength Spectrometer) has proven to be a delicate problem. We therefore present a detailed spectroscopic study in the 2.38 -- 12 micron wavelength range of…
The sky subtraction performances of multi-fiber spectrographs are discussed, analysing in detail the case of the OPTOPUS system at the 3.6 meter ESO telescope at La Silla. A standard technique, based on flat-fields obtained with a uniformly…
We present an updated calibration of the Swift/UVOT broadband ultraviolet (uvw1, uvm2, and uvw2) filters. The new calibration accounts for the ~1% per year decline in the UVOT sensitivity observed in all filters, and makes use of additional…
This paper proposes a novel and rapid calibration-free wavelength modulation spectroscopy algorithm based on even-order harmonics. The proposed algorithm, analytically deduced from Voigt line-shape function, only involves simple algebraic…
The Gemini Planet Imager (GPI) has as its science instrument an infrared integral field spectrograph/polarimeter (IFS). Integral field spectrographs are scientificially powerful but require sophisticated data reduction systems. For GPI to…
With the emergence of swept-volume ultrasound (US) probes, precise and almost real-time US volume imaging has become available. This offers many new opportunities for computer guided diagnosis and therapy, 3-D images containing…
We propose a new methodology for probing the cosmological variability of alpha from pairs of FeII lines (SIDAM, single ion differential alpha measurement) observed in individual exposures from a high resolution spectrograph. By this we…
We describe the calibration status and data products pertaining to the GR2 and GR3 data releases of the Galaxy Evolution Explorer (GALEX). These releases have identical pipeline calibrations that are significantly improved over the GR1 data…
We present a new automatic code (ARES) for determining equivalent widths of the absorption lines present in stellar spectra. We also describe its use for determining fundamental spectroscopic stellar parameters. The code is written in C++…
This paper addresses the problem of choosing a sparse subset of measurements for quick calibration parameter estimation. A standard solution to this is selecting a measurement only if its utility -- the difference between posterior (with…
Achieving a truly accurate wavelength calibration of high-dispersion echelle spectrographs is a challenging task but crucially needed for certain science cases, e.g. to test for a possible variation of the fine-structure constant in quasar…