Related papers: Level-3 Calorimetric Resolution available for the …
Since the beginning of Run II at the Fermilab Tevatron, the QCD physics groups of the CDF and D0 experiments have worked to reach unprecedented levels of precision for many QCD observables. Thanks to the large dataset - over 3 fb^-1 of…
The Forward Detector upgrade project at CDF is designed to enhance the capabilities for studies of diffractive physics at the Tevatron during Run II. Studies of hard diffraction and very forward physics are some of the topics that can be…
Since a lot of theoretical predictions on the production of new particles (Higgs, SUSY) at the Tevatron are based on model estimations of the proton gluon density behavior at low $x$ and high values of a transfered momentum Q^2, the study…
In this paper we discuss the luminosity determination at the Tevatron. We discuss luminosity measurements by the machine as well as by using the luminosity detectors of the CDF and D0 experiments. We discuss the uncertainties of the…
The Level-1 Muon Barrel Trigger of the ATLAS Experiment at LHC makes use of Resistive Plate Chamber (RPC) detectors. The on-detector trigger electronics modules are able to identify muons with predefined transverse momentum values (pT) by…
The ALICE Collaboration completed the upgrade of the detector and is now commissioning for the beginning of the data taking during LHC Run 3. In parallel, R&D activities and simulation studies are being performed to define the future of the…
The Phase-2 Upgrade of the CMS Level-1 Trigger (L1T) will reconstruct particles using the Particle Flow algorithm, connecting information from the tracker, muon, and calorimeter detectors, and enabling fine-grained reconstruction of high…
Calorimeters operating in high-radiation environments are susceptible to damage, leading to increased noise that can significantly degrade energy resolution. A common way to mitigate noise is to apply a higher energy threshold on the cells,…
We derive a new method to improve the statistics of identified particles at high transverse momentum (\pt) using online-triggered events by the Barrel Electro-Magnetic-Calorimeter (BEMC) detector. The BEMC is used to select hadronic…
The CMS Level-1 trigger was used to select cosmic ray muons and LHC beam events during data-taking runs in 2008, and to estimate the level of detector noise. This paper describes the trigger components used, the algorithms that were…
The particle flow approach to calorimetry can provide unprecedented jet energy resolution at a future high energy collider, such as the International Linear Collider (ILC). However, the use of particle flow calorimetry at the proposed…
Measuring the region $0.1 < Q^{2} < 1.0$ GeV$^{2}$ is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not…
The high flux of charged particles interacting with the CMS Forward Hadron Calorimeter PMT windows introduced a significant background for the trigger and offline data analysis. During Long Shutdown 1, all of the original PMTs were replaced…
The Pixel Detector is the innermost detector of the tracking system of the Compact Muon Solenoid (CMS) experiment at CERN Large Hadron Collider (LHC). It precisely determines the interaction point (primary vertex) of the events and the…
The D0 and CDF experiments have been taking data at the Run 2 of the Tevatron Collider since 2001. We present a selection of recent results, most of them obtained with an integrated luminosity of $\simeq$ 1 fb$^{-1}$. I will describe the…
A determination of the jet energy scale is presented using proton$-$proton collision data with a centre-of-mass energy of $\sqrt{s}=13$ TeV, corresponding to an integrated luminosity of 140 $\mbox{fb\(^{-1}\)}$ collected using the ATLAS…
As PEP-II is exceeding the original design luminosity, BaBar is currently upgrading its Level 1 Drift Chamber Trigger (DCT) to reduce the rate of background Level 1 triggers by more than 50% while preserving the high Level 1 trigger physics…
The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…
The ATLAS tile calorimeter (TileCal) is the hadronic sampling calorimeter covering the central region of the ATLAS detector at the Large Hadron Collider (LHC). This paper gives an overview of the calorimeter's operation and performance…
Most of the physics analyses at a hadron collider rely on a precise measurement of the energy of jets in the final state. This requires a precise in situ calibration of the calorimeter with the final detector setup. We present the basic…