Related papers: XPOL: a photoelectric polarimeter onboard XEUS
The degree of linear polarization in solar flares has not yet been precisely determined despite multiple attempts to measure it with different missions. The high energy range in particular has very rarely been explored, due to its greater…
We present measurements of the polarization of X-rays in the 2-8 keV band from the pulsar in the ultracompact low mass X-ray binary 4U1626-67 using data from the Imaging X-ray Polarimetry Explorer (IXPE). The 7.66 s pulsations were clearly…
We present a series of numerical models suitable for X-ray polarimetry of accreting systems. Firstly, we provide a spectropolarimetric routine that integrates reflection from inner optically thick walls of a geometrical torus of arbitrary…
X-ray astronomy allows study of objects which may be associated with compact objects, i.e. neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically non-spherical, and likely non-circular when…
We employ our new model for the polarised emission of accreting X-ray pulsars to describe the emission from the luminous X-ray pulsar Hercules X-1. In contrast with previous works, our model predicts the polarisation parameters…
X-ray polarization measurement of cosmic sources provides two unique parameters namely degree and angle of polarization which can probe the emission mechanism and geometry at close vicinity of the compact objects. Specifically, the hard…
A high quality beam of linearly polarized photons of several GeV will become available with the coherent bremsstrahlung technique at JLab. We have developed a polarimeter which requires about two meters of the beam line, has an analyzing…
The Hokupa'a-85 curvature adaptive optics system components have been adapted to create a new AO-corrected coud\'{e} instrument at the 3.67m Advanced Electro-Optical System (AEOS) telescope. This new AO-corrected optical path is designed to…
An Andor 1K $\times$ 1K EMCCD detector has been used to develop an optical imaging polarimeter for use at the Cassegrain focus of 1.2 m telescope of PRL. The optics is derived from an older single-element detector instrument and consists of…
We present the first X-ray polarimetric measurement of the neutron star low-mass X-ray binary system AX J1745.6-2901 conducted by the Imaging X-ray Polarimetry Explorer (IXPE) satellite. This transient source, located within $ \sim $1.5' of…
Hard X / soft gamma-ray polarimetric analysis can be performed efficiently by the study of Compton scattering anisotropy in a detector composed of fine pixels. But in the energy range above 100 keV where sources flux are extremely weak and…
The INFN and INAF Italian research institutes developed a space-borne X-Ray polarimetry experiment based on a X-Ray telescope, focussing the radiation on a Gas Pixel Detector (GPD). The instrument obtains the polarization angle of the…
POLAR is a space-borne hard X-ray Compton polarimeter built by a collaboration of institutes from Switzerland, China and Poland. Precise detection of the polarization can be a powerful tool to unveil emission mechanisms of e.g. Gamma-Ray…
Recent X-ray polarimetric data on the prototypical black hole X-ray binary Cyg~X-1 from the Imaging X-ray Polarimetry Explorer present tight constraints on accretion geometry in the hard spectral state. Contrary to general expectations of a…
The Gas Pixel Detector is a gas detector, sensitive to the polarization of X-rays, currently flying on-board IXPE - the first observatory dedicated to X-ray polarimetry. It detects X-rays and their polarization by imaging the ionization…
Operational since 2002 on-board the INTEGRAL observatory, the SPI spectrometer can be used to perform polarization measurements in the hard X-ray/soft gamma-ray domain (~ 130 keV - 8 MeV). However, this phenomenon is complex to measure at…
We present SPLOT, a small scale pilot survey to test the potential of snapshot (single epoch) linear imaging polarimetry as a supplementary tool to traditional transient follow-up. Transients exist in a vast volume of observational…
Photons preferentially Compton scatter perpendicular to the plane of polarisation. This property can be exploited to design instruments to measure the linear polarisation of hard X-rays ($\sim$10 - 100 keV). Photons may undergo two…
We theoretically study the spatial focusing of surface polaritons (SPs) in a negative index metamaterial (NIMM)-atomic gas interface waveguide system, based on cross phase modulation (XPM) in a tripod type double electromagnetically induced…
This dissertation elaborates on X-ray polarisation features of astrophysical environments near accreting black holes. Although the work was originally assigned to supermassive black holes in active galactic nuclei, the results are also…