Related papers: The Nemo-3 Experiment and the Supernemo Project
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0\nu\beta\beta$) decay search in $^{136}$Xe, based on the ultra-low…
SNO+ is a large multipurpose experiment with the ultimate goal of searching for the neutrinoless double beta decay in $^{130}\mathrm{Te}$. After a commissioning phase with water as the target medium, during which acquired data allowed for…
The main physics goal of the SNO+ experiment is the search for neutrinoless double-beta decay (0$\nu\beta\beta$), a rare process which if detected, will prove the Majorana nature of neutrinos and provide information on the absolute scale of…
The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right)…
Using data from the NEMO-3 experiment, we have measured the two-neutrino double beta decay ($2\nu\beta\beta$) half-life of $^{82}$Se as $T_{1/2}^{2\nu} = \left[ 9.39 \pm 0.17\,\left(\mbox{stat}\right) \pm…
The LEGEND experiment is looking for the extremely rare neutrinoless double beta ($0\nu\beta\beta$) decay of $^{76}$Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the…
A large experimental program is being mounted to search for neutrinoless double-beta decay over the next decade. Multiple experiments using different target isotopes are being prepared to explore the whole parameter space allowed for…
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment…
The search for neutrino-less double-beta decay has been a very active field of research in the last decade. Neutrino-less double-beta decay may answer essential open questions in neutrino physics. While double-beta decay accompanied by the…
The double beta decay of 100Mo to the 0^+_1 and 2^+_1 excited states of 100Ru is studied using the NEMO 3 data. After the analysis of 8024 h of data the half-life for the two-neutrino double beta decay of 100Mo to the excited 0^+_1 state is…
We give the present status of the beta-beam study, which aims at producing intense nue and antinue beams from the decay of relativistic radioactive io ns. The emphasis is put on recent technical progress and new ideas. The expected…
NEXT-DEMO is a 1:4.5 scale prototype of the NEXT100 detector, a high-pressure xenon gas TPC that will search for the neutrinoless double beta decay of $^{136}$Xe. X-ray energy depositions produced by the de-excitation of Xenon atoms after…
The NEXT-100 detector will search for the neutrinoless double beta decay of $^{136}$Xe using an electroluminescent high-pressure xenon gas TPC filled with 100 kg of enriched Xe. An observation of this hypothetical process would establish a…
A high pressure xenon gas time projection chamber with electroluminescent amplification (EL HPGXe TPC) searching for the neutrinoless double beta ($0\nu\beta\beta$) decay offers: excellent energy resolution ($0.5-0.7\%$ FWHM at the…
The search for neutrinoless double beta decay ($0\nu\beta\beta$) is one of the key experiments for determining unresolved properties of neutrinos. Experimental observation of $0\nu\beta\beta$ would provide a clear demonstration of the…
Results from a search for neutrinoless double-beta decay $0\nu\beta\beta$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of…
The simultaneous beta decay of two neutrons in a nucleus without the emission of neutrinos (called neutrinoless double beta decay) is a lepton number violating process which is not allowed in the Standard Model of particle physics. More…
This Letter reports results from the NEMO-3 experiment based on an exposure of 1275 days with 661g of 130Te in the form of enriched and natural tellurium foils. The double beta decay rate of 130Te is found to be greater than zero with a…
In the double beta decay experiment NEMO~3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO~3 to evaluate the backgrounds resulting from most if not all…
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in 208Tl and 214Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m2 of sensitive surface area,…