Related papers: Recent results from the CDMS-II experiment
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed…
The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode…
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three…
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400-g heat-and-ionization cryogenic detectors equipped with Inter-Digit electrodes for the rejection of near-surface events. Results from…
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded.…
The Cryogenic Dark Matter Search experiment uses low-temperature solid-state detectors to seek Weakly Interacting Massive Particles (WIMPs) and has the world's best exclusion limit on the spin-independent WIMP-nucleon cross section. The…
We are conducting an experiment to search for WIMPs, or weakly-interacting massive particles, in the galactic halo using terrestrial detectors. This generic class of hypothetical particles, whose properties are similar to those predicted by…
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are…
The SuperCDMS experiment searches for weakly interacting massive particles (WIMPs) using cryogenic germanium detectors that measure ionization and phonon energy. Several direct searches for WIMPs have recently reported excesses of events…
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices…
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from a low-threshold analysis of a single upgraded detector module. This module…
We present a search for low-mass ($\leq 20 GeV/c^{2}$) weakly interacting massive particles(WIMPs), strong candidates of dark matter particles,using the low-background CsI(Tl) detector array of the Korea Invisible Mass Search (KIMS)…
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and…
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon…
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total…
Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very…
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of…
WIMP-nucleon cross sections in the range 10^{-46} - 10^{-44} cm^2 may be probed by a ton-scale experiment with low energy thresholds and excellent discrimination of backgrounds. Because CDMS ZIP detectors are the most proven means of…
We report on the search for dark matter WIMPs in the mass range below 10 GeV/c$^2$, from the analysis of the entire dataset acquired with a low-radioactivity argon target by the DarkSide-50 experiment at LNGS. The new analysis benefits from…