English
Related papers

Related papers: A large area plastic scintillator detector array f…

200 papers

The NeuLAND (New Large-Area Neutron Detector) plastic-scintillator-based time-of-flight detector for 0.1-1.6 GeV neutrons is currently under construction at the Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. In its…

Instrumentation and Detectors · Physics 2023-01-11 Thomas Hensel , David Weinberger , Daniel Bemmerer , Konstanze Boretzky , Igor Gašparić , Daniel Stach , Andreas Wagner , Kai Zuber

In order to measure energy and fluence of neutron fields, with energy ranging from 8 keV to 1 MeV, a new primary standard is being developed at the IRSN (Institute for Radioprotection and Nuclear Safety). This project, micro-TPC (Micro Time…

Instrumentation and Detectors · Physics 2014-10-29 D. Maire , J. Billard , G. Bosson , O. Bourrion , O. Guillaudin , J. Lamblin , L. Lebreton , F. Mayet , J. Médard , J-F. Muraz , J-P. Richer , Q. Riffard , D. Santos

The energy spectra of the neutrons emitted following nuclear muon capture on palladium isotopes ($A=104$, 105, 106, 108, and 110) were measured using isotopically enriched target. \item[Method] The experiment was performed at the MuSIC-M1…

The organic liquid scintillator used in the LVD experiment (INFN Gran Sasso National Laboratory) has been exposed to an Am-Be neutron source to measure the light response function for neutron energies in the region from about 4 to 11 MeV. A…

Instrumentation and Detectors · Physics 2014-10-22 G. Bruno

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in…

A multi-detector array has been designed and constructed for the simultaneous measurement of energy- and angular correlations of electron-positron pairs. Experimental results are obtained over a wide angular range for high-energy…

Accelerator-driven system (ADS) facilities world-wide opens new opportunities for nuclear physics investigations, so that a high flux of neutrons through spallation reactions can be produced at these facilities. It is known that the…

Instrumentation and Detectors · Physics 2023-04-27 S. Nuruyev , D. Berikov , R. Akbarov , G. Ahmadov , F. Ahmadov , A. Sadigov , M. Holik , J. Naghiyev , A. Madadzada , K. Udovichenko

Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to…

Gamma-ray and fast-neutron imaging was performed with a novel liquid xenon (LXe) scintillation detector read out by a Gaseous Photomultiplier (GPM). The 100 mm diameter detector prototype comprised a capillary-filled LXe…

Instrumentation and Detectors · Physics 2017-10-04 I. Israelashvili , A. E. C. Coimbra , D. Vartsky , L. Arazi , S. Shchemelinin , E. N. Caspi , A. Breskin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This work presents a fabrication method based on additive…

Instrumentation and Detectors · Physics 2026-04-28 Chandler Moore , Juan Manfredi , Michael Febbraro , Daniel Rutstrom , Andrew Decker , Ryan Kemnitz , Thomas Ruland , Paul Hausladen

The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed…

Nuclear Experiment · Physics 2019-09-04 S. Amaducci , L. Cosentino , M. Barbagallo , N. Colonna , A. Mengoni , C. Massimi , S. Lo Meo , P. Finocchiaro , O. Aberle , J. Andrzejewski , L. Audouin , M. Bacak , J. Balibrea , F. Bečvář , E. Berthoumieux , J. Billowes , D. Bosnar , A. Brown , M. Caamaño , F. Calviño , M. Calviani , D. Cano-Ott , R. Cardella , A. Casanovas , F. Cerutti , Y. H. Chen , E. Chiaveri , G. Cortés , M. A. Cortés-Giraldo , L. A. Damone , M. Diakaki , C. Domingo-Pardo , R. Dressler , E. Dupont , I. Durán , B. Fernández-Domínguez , A. Ferrari , P. Ferreira , V. Furman , K. Göbel , A. R. García , A. Gawlik , S. Gilardoni , T. Glodariu , I. F. Gonçalves , E. González-Romero , E. Griesmayer , C. Guerrero , F. Gunsing , H. Harada , S. Heinitz , J. Heyse , D. G. Jenkins , E. Jericha , F. Käppeler , Y. Kadi , A. Kalamara , P. Kavrigin , A. Kimura , N. Kivel , I. Knapova , M. Kokkoris , M. Krtička , D. Kurtulgil , E. Leal-Cidoncha , C. Lederer , H. Leeb , J. Lerendegui-Marco , S. J. Lonsdale , D. Macina , A. Manna , J. Marganiec , T. Martínez , A. Masi , P. Mastinu , M. Mastromarco , E. A. Maugeri , A. Mazzone , E. Mendoza , P. M. Milazzo , F. Mingrone , A. Musumarra , A. Negret , R. Nolte , A. Oprea , N. Patronis , A. Pavlik , J. Perkowski , I. Porras , J. Praena , J. M. Quesada , D. Radeck , T. Rauscher , R. Reifarth , C. Rubbia , J. A. Ryan , M. Sabaté-Gilarte , A. Saxena , P. Schillebeeckx , D. Schumann , P. Sedyshev , A. G. Smith , N. V. Sosnin , A. Stamatopoulos , G. Tagliente , J. L. Tain , A. Tarifeño-Saldivia , L. Tassan-Got , S. Valenta , G. Vannini , V. Variale , P. Vaz , A. Ventura , V. Vlachoudis , R. Vlastou , A. Wallner , S. Warren , C. Weiss , P. J. Woods , T. Wright , P. Žugec

We report a direct detection of muon-induced high energy neutrons with a 12-liter neutron detector fabricated with EJ-301 liquid scintillator operating at Soudan Mine for about two years. The detector response to energy from a few MeV up to…

Instrumentation and Detectors · Physics 2014-12-31 C. Zhang , D. -M. Mei

We present a method for detecting neutrons using scintillating lithium gadolinium borate crystal shards in a plastic matrix while maintaining high gamma rejection. We have procured two cylindrical detectors, 5"\times5", containing 1%…

Nuclear Experiment · Physics 2011-09-20 Kareem Kazkaz , Nathaniel S. Bowden , Marisa Pedretti

A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron…

Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic…

Instrumentation and Detectors · Physics 2021-07-14 J. J. Manfredi , B. L. Goldblum , T. A. Laplace , G. Gabella , J. Gordon , A. O'Brien , S. Chowdhury , J. A. Brown , E. Brubaker

We present the development of a segmented fast neutron spectrometer (FaNS-2) based upon plastic scintillator and $^3$He proportional counters. It was designed to measure both the flux and spectrum of fast neutrons in the energy range of few…

Instrumentation and Detectors · Physics 2016-01-19 FaNS Collaboration , T. J. Langford , E. J. Beise , H. Breuer , C. R. Heimbach , G. Ji , J. S. Nico

A neutron counter designed for assay of radioactive materials has been adapted for beam experiments at TUNL. The cylindrical geometry and 60% maximum efficiency make it well suited for ($\gamma,n$) cross-section measurements near the…

Nuclear Experiment · Physics 2015-03-17 C. W. Arnold , T. B. Clegg , H. J Karwowski , G. C. Rich , J. R. Tompkins , C. R. Howell

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

A large 4$\pi$ array of charged particle detectors has been developed at Variable Energy Cyclotron Centre to facilitate high resolution charged particle reaction and spectroscopy studies by detecting event-by-event the charged reaction…

There has been an increasing interest in the monitoring of nuclear fuel for power reactors by detecting the anti-neutrinos produced during operation. Small liquid scintillator detectors have already demonstrated sensitivity to operational…

Instrumentation and Detectors · Physics 2007-05-23 R. W. McKeown , D. E. Reyna