Understanding the physical world is a continuous process of trial and error. It requires theoretical background and tools to find out the theory's accuracy. Particles motion through matter, and their energy loss is one such process. Testing…
Experiments searching for extremely rare events surround their sensitive detectors with several layers of different shielding materials to protect them from external radiation and to achieve their low-background requirements to be able to…
An accurate description of interactions between thermal neutrons (below 4 eV) and materials is key to simulate the transport of neutrons in a wide range of applications such as criticality-safety, reactor physics, compact accelerator-driven…
The KM3NeT Collaboration has successfully deployed the first detection units of the next generation undersea neutrino telescopes in the Mediterranean Sea at the two sites in Italy and in France. The data sample collected between December…
The novel idea of water Cherenkov calorimeter made of water tanks as the next generation neutrino detector for nu factories and nu beams is investigated. A water tank prototype with a dimension of 1*1*13m^3 is constructed, its performance…
The HL-LHC and the corresponding detector upgrades for the CMS experiment will present extreme challenges for the full simulation. In particular, increased precision in models of physics processes may be required for accurate reproduction…
To characterize the signals registered by the different types of water Cherenkov detectors (WCD) used by the Latin American Giant Observatory (LAGO) Project, it is necessary to develop detailed simulations of the detector response to the…
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single…
A sampling calorimeter equipped with gaseous sensor layers with digital readout is near perfect for "Particle Flow Algorithm" approach, since it is homogeneous over large surfaces, robust, cost efficient, easily segmentable to any readout…
The features of the HEMAS code are presented. The results of the comparison between the Monte Carlo expectation and the experimental data are shown.
A Monte Carlo event generator has been developed assuming thermal production of hadrons. The system under consideration is sampled grand canonically in the Boltzmann approximation. A re-weighting scheme is then introduced to account for…
The two calorimeters CASTOR and ZDCs enhance the hermeticity of the CMS detector at the LHC by extending the rapidity coverage in the forward region. After having described these detectors, their forward physics capabilities are presented.…
We present a summary of recent tests and measurements of hadronic interaction properties with air showers. This report has a special focus on muon density measurements. Several experiments reported deviations between simulated and recorded…
The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…
Precision measurements and new physics searches at the Large Hadron Collider require efficient simulations of particle propagation and interactions within the detectors. The most computationally expensive simulations involve calorimeter…
Recent results obtained from leading cosmic ray experiments indicate that simulations using LHC-tuned hadronic interaction models underestimate the number of muons in extensive air showers compared to experimental data. This is the…
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here…
Direct detection of bremsstrahlung photons, in principle, offers the most straightforward and most robust method of luminosity determination at the EIC, but requires an extraordinary performance of the photon detector. In this paper, we…
We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton…
An improved weighting algorithm applied to hadron showers has been developed for a fine grained LAr calorimeter. The new method uses tabulated weights which depend on the density of energy deposited in individual cells and in a surrounding…