Related papers: Using the etalon effect for in-situ balancing of t…
Optomechanics with semi-transparent membrane multi-oscillators in a high-finesse cavity is an established solution for designing the dispersive interaction, and reaching many achievements, such as the study of non-linear dynamics, heat…
Increasing the laser power is essential to improve the sensitivity of interferometric gravitational wave detectors. However, optomechanical parametric instabilities can set a limit to that power. It is of major importance to understand and…
We present a fast time-domain simulator for optical cavities capable of reproducing non-linear dynamical regimes arising from ring-down effect during resonance crossings at high mirror velocities. The model is based on a recursive…
High polarization selective Si/SiO2 mid-infrared sub-wavelength grating mirrors with large bandwidth adapted to VCSEL integration are compared. These mirrors have been automatically designed for operation at \lambda = 2.3 $\mu$m by an…
A modified-weak-value-amplification(MWVA) technique of measuring the mirror's velocity based on the Vernier-effect has been proposed. We have demonstrated with sensitivity-enhanced and the higher signal-to-noise ratio(${\rm SNR}$) by using…
Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing…
In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called 'superattenuator', is fully effective…
The Advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the…
The sensitivity of kilometer-scale terrestrial gravitational wave interferometers is limited by mirror coating thermal noise. We explore the effect of folding the arm cavities of such interferometers. While simple folding alone does not…
Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an…
This paper demonstrates a vibration test for a resonant MEMS scanning system in operation to evaluate the vibration immunity for automotive lidar applications. The MEMS mirror has a reinforcement structure on the backside of the mirror,…
We propose a procedure for the significant enhancement of the strong coupling rate between photons in an optical cavity and a single quantum emitter, such as an atom, quantum dot or trapped ion. We show that specially designed,…
The performance of mirrors in optical interferometers is critically influenced by their surface quality. Accurate metrology enables mirror surfaces to be characterized through phase maps describing their three-dimensional structure after…
Low energy non linear QED effects in vacuum have been predicted since 1936 and have been subject of research for many decades. Two main schemes have been proposed for such a 'first' detection: measurements of ellipticity acquired by a…
Recently, Adaptive Secondary Mirrors showed excellent on-sky results in the Near Infrared wavelengths. They currently provide 30mm inter-actuator spacing and about 1 kHz bandwidth. Pushing these devices to be operated at visible wavelengths…
We describe the angular sensing and control of the 4 km detectors of the Laser Interferometer Gravitational-wave Observatory (LIGO). The culmination of first generation LIGO detectors, Enhanced LIGO operated between 2009 and 2010 with about…
High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform…
Michelson-type laser-interferometric gravitational-wave (GW) observatories employ very high light powers as well as transmissively- coupled Fabry-Perot arm resonators in order to realize high measurement sensitivities. Due to the absorption…
As part of the upgrade program of the Advanced Virgo interferometer, the installation of new instrumented baffles surrounding the main test masses is foreseen. As a demonstrator, and to validate the technology, the existing baffle in the…
We present a novel atom interferometer configuration that combines large momentum transfer with the enhancement of an optical resonator for the purpose of measuring gravitational strain in the horizontal directions. Using Bragg diffraction…