Related papers: Cold performance tests of blocked-impurity-band Si…
A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector concept, one of the two detector concepts for the future International Linear Collider.…
A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI…
Bulk silicon carbide (SiC) is a very promising material system for bio-applications and quantum sensing. However, its optical activity lies beyond the near infrared spectral window for in-vivo imaging and fiber communications due to a large…
CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In…
At Argonne National Laboratory, we are developing hard X-ray (2 to 20 keV) Transition Edge Sensor (TES) arrays for beamline science. The significantly improved energy resolution provided by superconducting detectors compared to…
Single-photon imaging spectrometers of high quantum efficiency in the infrared to ultraviolet wavelength range, with good timing resolution and with a vanishing dark count rate are on top of the wish list in earth-bound astronomy, material…
Quantum Well Infrared Photodetector (QWIP) usually suffer from a too moderate quantum efficiency and too large dark current which is often announced as crippling for low flux applications. Despite this reputation we demonstrate the ability…
We have developed the deposition technology of WSi thin films 4 to 9 nm thick with high temperature values of superconducting transition (Tc~4 K). Based on deposed films there were produced nanostructures with indicative planar sizes ~100…
Bent monolithic active pixel sensors are the basis for the planned fully cylindrical ultra low material budget tracking detector ITS3 of the ALICE experiment. This paper presents results from testbeam campaigns using high-energy particles…
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than…
We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic…
Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode…
Sodium iodide (NaI) based cryogenic scintillating calorimeters using quantum sensors for signal read out have shown promising first results towards a model-independent test of the annually modulating signal detected by the DAMA/LIBRA dark…
Silicon Carbide (SiC) demonstrates significant potential for high-energy particle detection in complex radiation environments due to its exceptional radiation resistance, excellent environmental adaptability, and fast response time.…
A 100um thick silicon detector with 1mm2 pad readout optimized for sub-nanosecond time resolution has been developed and tested. Coupled to a purposely developed amplifier based on SiGe HBT technology, this detector was characterized at the…
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated…
In ion cancer therapy, high-intensity ion beams are used to treat tumors by taking advantage of the Bragg-Peak. Typical ion therapy centers use particle rates up to $10^{10}$ ions/second for treatment. On the other hand, such intensities…
The Mid-Infrared Instrument (MIRI) on board the James Webb Space Telescope (JWST) uses three Si:As impurity band conduction (IBC) detector arrays. The output voltage level of each MIRI detector pixel is digitally recorded by…
This paper presents the first experimental validation of reflective near-field beamfocusing using a reconfigurable intelligent surface (RIS). While beamfocusing has been theoretically established as a key feature of large-aperture RISs, its…
The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high…