Related papers: Imaging X-ray sources at a finite distance in code…
Context. In coded mask techniques, reconstructed sky images are pseudo-images: they are maps of the correlation between the image recorded on a detector and an array derived from the coded mask pattern. Aims. The INTEGRAL/IBIS telescope…
We consider the problem of reconstructing one-dimensional point sources from their Fourier measurements in a bounded interval $[-\Omega, \Omega]$. This problem is known to be challenging in the regime where the spacing of the sources is…
The coded aperture imaging technique is a useful method of X-ray imaging in observational astrophysics. However, the presence of imaging noise or so-called artifacts in a decoded image is a drawback of this method. We propose a new coded…
High angular resolution X-ray imaging is always demanded by astrophysics and solar physics, which can be realized by coded-mask imaging with very long mask-detector distance in principle. Previously the diffraction-interference effect has…
Inverse source problems are central to many applications in acoustics, geophysics, non-destructive testing, and more. Traditional imaging methods suffer from the resolution limit, preventing distinction of sources separated by less than the…
3D-localization of gamma sources has the potential to improve the outcome of radio-guided surgery. The goal of this paper is to analyze the localization accuracy for point-like sources with a single coded aperture camera. We both simulated…
The far-field resolution of optical imaging systems is restricted by the Abbe diffraction limit, a direct result of the wave nature of light. One successful technological approach to circumventing this limit is to reduce the effective size…
The goal of anomaly detection is to identify examples that deviate from normal or expected behavior. We tackle this problem for images. We consider a two-phase approach. First, using normal examples, a convolutional autoencoder (CAE) is…
Estimating the angular separation between two incoherent thermal sources is a challenging task for direct imaging, especially when it is smaller than or comparable to the Rayleigh length. In addition, the task of discriminating whether…
Hard X-ray and low-energy gamma-ray coded-aperture imaging instruments have been highly successful as high-energy surveyors and transient-source discoverers and trackers over the past decades. Albeit having relatively low sensitivity as…
We describe and experimentally validate an algorithm to reconstruct an unknown extended object from through-focus measured image intensities blurred by unknown aberrations. It is shown that the method can recover diffraction-limited image…
Using a series of detector measurements taken at different locations to localize a source of radiation is a well-studied problem. The source of radiation is sometimes constrained to a single point-like source, in which case the location of…
The concept of two perpendicular one-dimensional coded aperture cameras, necessitated by the imaging capability of the detector, finds its application in the design of the Wide Field Monitor (WFM). This instrument has the future goal to…
Photometric surveys have provided incredible amounts of astronomical information in the form of images. However, astronomical images often contain artifacts that can critically hinder scientific analysis by misrepresenting intensities or…
We demonstrate an approach to obtaining near quantum-limited far-field imaging resolution of incoherent sources with arbitrary distributions. Our method assumes no prior knowledge of the source distribution, but rather uses an adaptive…
I propose a spatial-mode demultiplexing (SPADE) measurement scheme for the far-field imaging of spatially incoherent optical sources. For any object too small to be resolved by direct imaging under the diffraction limit, I show that SPADE…
Coherent diffractive imaging (CDI) provides new opportunities for high resolution X-ray imaging with simultaneous amplitude and phase contrast. Extensions to CDI broaden the scope of the technique for use in a wide variety of experimental…
Purpose: Handheld gamma cameras with coded aperture collimators are under investigation for intraoperative imaging in nuclear medicine. Coded apertures are a promising collimation technique for applications such as lymph node localization…
We determine the ultimate potential of quantum imaging for boosting the resolution of a far-field, diffraction-limited, linear imaging device within the paraxial approximation. First we show that the problem of estimating the separation…
Resolving sources beyond the diffraction limit is important in imaging, communications, and metrology. Current image-based methods of super-resolution require phase information (either of the source points or an added filter) and perfect…