English
Related papers

Related papers: Study of Micro Pixel Photon Counter for the Applic…

200 papers

The multi-pixel photon counter (MPPC) is a newly developed photodetector with an excellent photon counting capability. It also has many attractive features such as small size, high gain, low operation voltage and power consumption, and…

Multi-Pixel Photon Counter (MPPC) has been recently emerged and realized as a great type of Silicon Photomultiplier to replace or compensate for the conventional vacuum-based Photomultiplier tubes. MPPC provides many striking features such…

Instrumentation and Detectors · Physics 2021-06-17 N. H. Duy Thanh , N. V. Chi Lan , C. V. Son , T. V. Ngoc , P. T. Quyen , N. Khoa , N. T. Hong Van

We present the original computer code for the simulation of multi-element detection system of the compact positron-emission tomograph based on a scintillator-photodiode type of detection elements. The use of such type of detection elements…

Medical Physics · Physics 2017-05-08 Alex Fomin

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of…

Instrumentation and Detectors · Physics 2009-11-11 H. Sekiya , K. Hattori , H. Kubo , K. Miuchi , T. Nagayoshi , H. Nishimura , Y. Okada , R. Orito , A. Takada , A. Takeda , T. Tanimori , K. Ueno

The application of silicon photomultiplier (SiPM) technology for weak-light detection at a single photon level has expanded thanks to its better photon detection efficiency in comparison to a conventional photomultiplier tube (PMT). SiPMs…

Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…

Instrumentation and Detectors · Physics 2025-02-19 Binghao Sun , Huiling Li , Quanyin Li , Hui Liang , Cong Liu , Hongbo Wang , Zibing Wu , Suyu Xiao , Weiwei Xu

The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…

Instrumentation and Detectors · Physics 2025-02-06 M. X. Wang , Y. Liu , Y. Q. Tan , J. N. Tang , W. H. Wu , D. L. Xu , W. Zhi , Z. Z. Zhou

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

We characterized the S13360-3050CS Multi-Pixel Photon Counter (MPPC), a silicon photomultiplier (SiPM) manufactured by Hamamatsu Photonics K.K.. Measurements were obtained inside a light tight dark box using 365 nm, 400 nm, 525 nm, 660 nm,…

Instrumentation and Methods for Astrophysics · Physics 2019-09-18 Siyang Li , George F. Smoot

We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides…

Instrumentation and Detectors · Physics 2022-01-26 M. Follin , R. Chyzh , C. -H. Sung , D. Breton , J. Maalmi , T. Chaminade , E. Delagnes , K. Schäfers , C. Weinheimer , D. Yvon , V. Sharyy

In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector---a high sensitivity, low cost, and real-time radon monitor based on \textit{Topmetal-${II}^-$} time projection chamber (TPC). Using…

Instrumentation and Detectors · Physics 2019-01-08 Mengyao Huang , Hua Pei , Xiangming Sun , Shuguang Zou

Multi-Pixel Photon Counters (MPPC) consist of hundreds of micro silicon Avalanche PhotoDiodes (APD) working in Geiger mode. The high gain and the low noise, typical of these devices, together with their good performance in magnetic field,…

Instrumentation and Detectors · Physics 2019-03-08 A. Scordo , M. Bazzi , C. Berucci , C. Curceanu , A. D'Uffizi , K. Piscicchia , M. Poli Lener , A. Romero Vidal , E. Sbardella , O. Vazquez Doce

A special type of Hamamatsu MPPC, with a sensitive area of 1.3x1.3mm^2 containing 667 pixels with 50x50um^2 each, has been developed for the near neutrino detector in the T2K long baseline neutrino experiment. About 60 000 MPPCs will be…

Instrumentation and Detectors · Physics 2009-11-13 M. Yokoyama , T. Nakaya , S. Gomi , A. Minamino , N. Nagai , K. Nitta , D. Orme , M. Otani , T. Murakami , T. Nakadaira , M. Tanaka , Yu. Kudenko , F. Retiere , A. Vacheret

Particle beams focused to micrometer-sized spots play a crucial role in forefront research using low-energy positrons. Their expedient and wide application, however, requires highly-resolved, fast beam diagnostics. We have developed two…

We characterized the S14160-3050HS Multi-Pixel Photon Counter (MPPC), a high efficiency, single channel silicon photomultiplier manufactured by Hamamatsu Photonics K.K. All measurements were performed at a room temperature of (23.0 $\pm$…

Instrumentation and Methods for Astrophysics · Physics 2020-12-21 Siyang Li , George F. Smoot

Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments.…

Instrumentation and Detectors · Physics 2021-12-08 I. Zoi , A. Ebrahimi , F. Feindt , E. Garutti , P. Gunnellini , A. Hinzmann , C. Niemeyer , D. Pitzl , J. Schwandt , G. Steinbrück

This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array…

Instrumentation and Detectors · Physics 2015-06-03 L. Gruber , G. S. M. Ahmed , S. E. Brunner , P. Bühler , J. Marton , K. Suzuki