Related papers: The absolute frequency of the 87Sr optical clock t…
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the…
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the $^{133}$Cs and $^{87}$Rb atomic fountains are described. Thanks to the routine use of a cryogenic…
An ultrastable optical clock based on neutral atoms trapped in an optical lattice is proposed. Complete control over the light shift is achieved by employing the $5s^2 {}^1S_0 \to 5s5p {}^3P_0$ transition of ${}^{87}{\rm Sr}$ atoms as a…
Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter…
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The…
A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock…
We have carried out calculations towards the goal of reducing the inaccuracy of the Sr optical atomic clock to 1$\times10^{-17}$ and below. We calculated a.c. polarizabilities of the $5s^2 ^1S_0$ and $5s5p ^3P_0^o$ clock states that are…
We present a comprehensive study of the frequency shifts associated with the lattice potential for a Sr lattice clock. By comparing two such clocks with a frequency stability reaching $5\times 10^{-17}$ after a one hour integration time,…
We report on a precision measurement of the differential static scalar polarizability $\Delta\alpha_0$ of the ${}^{2}\!S_{1/2} \rightarrow {}^{2}\!D_{5/2}$ optical clock transition in the $^{88}$Sr$^{+}$ ion. The polarizability was…
We present the first precise frequency measurement of the 2$^{1}$S$_{0}$-3$^{1}$D$_{2}$ two-photon transition in $^{4}$He at 1009 nm. The laser source at 1009 nm is stabilized on an optical frequency comb to perform the absolute frequency…
We demonstrate how to realize an optical clock with neutral atoms that is competitive to the currently best single ion optical clocks in accuracy and superior in stability. Using ultracold atoms in a Ca optical frequency standard we show…
The comparison of different atomic transition frequencies over time can be used to determine the present value of the temporal derivative of the fine structure constant alpha in a model-independent way without assumptions on constancy or…
Optical frequency standards, lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic…
We demonstrate a new technique for measuring the absolute frequencies of atomic transitions. The technique uses a ring-cavity resonator whose length is calibrated using a reference laser locked to the D_2 line in {87}Rb. The frequency of…
We report the development of a method for eliminating background-induced systematic shifts affecting precise measurements of saturation absorption signals. With this technique, we measured the absolute frequency of the $6s^2~^1\text{S}_0…
We demonstrate a technique for frequency measurements of atomic transitions with a precision of 30 kHz. The frequency is measured using a ring-cavity resonator whose length is calibrated against a reference laser locked to the $D_2$ line of…
We consider the frequency shift in optical lattice clocks which arises from the coupling of the electronic motion to the atomic motion within the lattice. For the simplest of 3-D lattice geometries this coupling is shown to only affect…
Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 x 10--19…
Neutral quantum absorbers in optical lattices have emerged as a leading platform for achieving clocks with exquisite spectroscopic resolution. However, the studies of these clocks and their systematic shifts have so far been limited to…
We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK…