English
Related papers

Related papers: A Semi-parametric Technique for the Quantitative A…

200 papers

Dynamic contrast-enhanced (DCE) MRI is an evolving imaging technique that provides a quantitative measure of pharmacokinetic (PK) parameters in body tissues, in which series of T1-weighted images are collected following the administration…

Computer Vision and Pattern Recognition · Computer Science 2018-06-13 Cagdas Ulas , Giles Tetteh , Michael J. Thrippleton , Paul A. Armitage , Stephen D. Makin , Joanna M. Wardlaw , Mike E. Davies , Bjoern H. Menze

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is essential for breast cancer diagnosis due to its ability to characterize tissue through contrast agent kinetics. However, traditional DCE-MRI protocols require multiple…

Computer Vision and Pattern Recognition · Computer Science 2025-01-28 Ruben D. Fonnegra , Maria Liliana Hernández , Juan C. Caicedo , Gloria M. Díaz

Dynamic contrast-enhanced (DCE) MRI is essential for breast cancer diagnosis and treatment. However, its reliance on contrast agents introduces safety concerns, contraindications, increased cost, and workflow complexity. To this end, we…

Image and Video Processing · Electrical Eng. & Systems 2025-09-16 Sebastian Ibarra , Javier del Riego , Alessandro Catanese , Julian Cuba , Julian Cardona , Nataly Leon , Jonathan Infante , Karim Lekadir , Oliver Diaz , Richard Osuala

This paper presents a method for virtual contrast enhancement in breast MRI, offering a promising non-invasive alternative to traditional contrast agent-based DCE-MRI acquisition. Using a conditional generative adversarial network, we…

Image and Video Processing · Electrical Eng. & Systems 2025-05-15 Richard Osuala , Smriti Joshi , Apostolia Tsirikoglou , Lidia Garrucho , Walter H. L. Pinaya , Daniel M. Lang , Julia A. Schnabel , Oliver Diaz , Karim Lekadir

In this work we consider the image reconstruction problem of sparsely sampled dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). DCE-MRI is a technique for acquiring a series of MR images before, during and after intravenous…

Image and Video Processing · Electrical Eng. & Systems 2020-02-24 Kati Niinimäki , Matti Hanhela , Ville Kolehmainen

DCE-MRI provides information about vascular permeability and tissue perfusion through the acquisition of pharmacokinetic parameters. However, traditional methods for estimating these pharmacokinetic parameters involve fitting tracer kinetic…

Image and Video Processing · Electrical Eng. & Systems 2023-06-08 Gyutaek Oh , Won-Jin Moon , Jong Chul Ye

Introduction: Quantification of dynamic contrast-enhanced (DCE)-MRI has the potential to provide valuable clinical information, but robust pharmacokinetic modeling remains a challenge for clinical adoption. Methods: A 7-layer neural network…

Medical Physics · Physics 2024-05-22 Ouri Cohen , Soudabeh Kargar , Sungmin Woo , Alberto Vargas , Ricardo Otazo

Breast cancer is the most common malignant tumor among women and the second cause of cancer-related death. Early diagnosis in clinical practice is crucial for timely treatment and prognosis. Dynamic contrast-enhanced magnetic resonance…

Image and Video Processing · Electrical Eng. & Systems 2024-05-13 Zixian Li , Yuming Zhong , Yi Wang

Tumor vascularity detection and quantification are of high relevance in the assessment of cancer lesions not only for disease diagnostics but for therapy considerations and monitoring. The present work addressed the quantification of…

Medical Physics · Physics 2023-05-23 Jhonalbert Aponte , Álvaro Ruiz , Jacksson Sánchez , Miguel Martín-Landrove

Despite its benefits for tumour detection and treatment, the administration of contrast agents in dynamic contrast-enhanced MRI (DCE-MRI) is associated with a range of issues, including their invasiveness, bioaccumulation, and a risk of…

Image and Video Processing · Electrical Eng. & Systems 2024-06-03 Richard Osuala , Smriti Joshi , Apostolia Tsirikoglou , Lidia Garrucho , Walter H. L. Pinaya , Oliver Diaz , Karim Lekadir

In the quantitative analysis of Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) compartment models allow to describe the uptake of contrast medium with biological meaningful kinetic parameters. As simple models often fail to…

Methodology · Statistics 2020-05-04 Julia C. Sommer , Volker J. Schmid

Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) is a valuable tool to localize, characterize, and evaluate anomalous prostate tissue. Ultrafast gradient-echo acquisitions of MRI volumes are generated at regular time intervals…

Medical Physics · Physics 2017-10-11 Wuilian Torres , Leonardo Cordero , Miguel Martín-Landrove , Antonio Rueda-Toicen

Dynamic Contrast-enhanced magnetic resonance imaging (DCE-MRI) is a tissue perfusion imaging technique. Some versatile free-breathing DCE-MRI techniques combining compressed sensing (CS) and parallel imaging with golden-angle radial…

Medical Physics · Physics 2020-07-08 Yuhan Hu , Xinlin Zhang , Li Feng , Dicheng Chen , Zhiping Yan , Xiaoyong Shen , Gen Yan , Lin Ou-yang , Xiaobo Qu

Contrast agents in dynamic contrast enhanced magnetic resonance imaging allow to localize tumors and observe their contrast kinetics, which is essential for cancer characterization and respective treatment decision-making. However, contrast…

Non-mass enhancing lesions (NME) constitute a diagnostic challenge in dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of the breast. Computer Aided Diagnosis (CAD) systems provide physicians with advanced tools for analysis,…

Image and Video Processing · Electrical Eng. & Systems 2018-09-27 Ignacio Alvarez Illan , Javier Ramirez , Juan M. Gorriz , Maria Adele Marino , Daly Avendaño , Thomas Helbich , Pascal Baltzer , Katja Pinker , Anke Meyer-Baese

Dynamic contrast-enhanced magnetic resonance imaging (DCE- MRI) is a widely used multi-phase technique routinely used in clinical practice. DCE and similar datasets of dynamic medical data tend to contain redundant information on the…

Purpose: To apply tracer kinetic models as temporal constraints during reconstruction of under-sampled dynamic contrast enhanced (DCE) MRI. Methods: A library of concentration v.s time profiles is simulated for a range of physiological…

This study aimed to propose a denoising method for dynamic contrast-enhanced computed tomography (DCE-CT) perfusion studies using a three-dimensional deep image prior (DIP), and to investigate its usefulness in comparison with total…

Medical Physics · Physics 2023-04-04 Kenya Murase

Objective: To develop an automatic image normalization algorithm for intensity correction of images from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) acquired by different MRI scanners with various imaging…

Computer Vision and Pattern Recognition · Computer Science 2018-07-09 Jun Zhang , Ashirbani Saha , Brian J. Soher , Maciej A. Mazurowski

Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) plays an important role in diagnosis and grading of brain tumor. Although manual DCE biomarker extraction algorithms boost the diagnostic yield of DCE-MRI by providing…

‹ Prev 1 2 3 10 Next ›