English
Related papers

Related papers: Development of one-coordinate gaseous detector for…

200 papers

Large area Gas Electron Multiplier (GEM) detectors have been the preferred choice for tracking devices in major nuclear and particle physics experiments. Uniformity over surface of the detector in terms of gain, energy resolution and…

Instrumentation and Detectors · Physics 2018-08-15 Rajendra Nath Patra , Rama N. Singaraju , Saikat Biswas , Zubayer Ahammed , Tapan K. Nayak , Yogendra P. Viyogi

We have developed a new detector of photons and charged particles- a hole-type structure with electrodes made of a double layered resistive material: a thin low resistive layer coated with a layer having a much higher resistivity. One of…

Instrumentation and Detectors · Physics 2008-11-26 G. Charpak , P. Benaben , P. Breuil , A. Di Mauro , P. Martinengo , V. Peskov

The "Wide Area VISTA Extra-galactic Survey" (WAVES) is a 4MOST Consortium Design Reference Survey which will use the VISTA/4MOST facility to spectroscopically survey ~2million galaxies to $r_{\rm AB} < 22$ mag. WAVES consists of two…

Cosmology and Nongalactic Astrophysics · Physics 2016-06-29 Simon P. Driver , Luke J. Davies , Martin Meyer , Chris Power , Aaron S. G. Robotham , Ivan K. Baldry , Jochen Liske , Peder Norberg

We are developing two-dimensional 16 x 25 pixel detector arrays of both unstressed and stressed Ge:Ga photoconductive detectors for far-infrared astronomy from SOFIA. The arrays, based on earlier 5 x 5 detector arrays used on the KAO, will…

Astrophysics · Physics 2015-06-24 D. Rosenthal , J. W. Beeman , N. Geis , L. Looney , A. Poglitsch , W. K. Park , W. Raab , A. Urban

GAW (Gamma Air Watch) is a new imaging Cherenkov telescope designed for observation of very high-energy gamma-ray sources. GAW will be equipped with a 3 meter diameter Fresnel lens as light collector and with an array of 300 multi-anode…

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude,…

We fabricated a superconducting single X-ray photon detector based on W0.8Si0.2, and we characterized its basic detection performance for keV-photons at different temperatures. The detector has a critical temperature of 4.97 K, and it is…

Instrumentation and Detectors · Physics 2016-10-31 X. Zhang , Q. Wang , A. Schilling

We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is…

Instrumentation and Detectors · Physics 2008-11-26 M. Cortesi , R. Alon , R. Chechik , A. Breskin , D. Vartsky , V. Dangendorf

Resonant X-ray scattering (RXS) is a spectroscopy where both the power of site selective diffraction and the power of local absorption spectroscopy regarding atomic species are combined. By virtue of the dependence on the core level state…

Materials Science · Physics 2007-11-12 Yves Joly , Elena S. Nazarenko , José-Emilio Lorenzo , Sergio Di Matteo , Calogero R. Natoli

We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The…

Properties of response functions of room temperature gamma-radiation detectors based on wide band-gap semiconductors are researched using Monte-Carlo method. It is shown that approximate formulas which connect detector sensitivity with…

Instrumentation and Detectors · Physics 2012-07-24 Alexandr A. Zakharchenko

Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National…

We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at $500~\mathrm{eV}$. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the…

We present a Bayesian estimation analysis for a particular trace gas detection technique with species separation provided by differential diffusion. The proposed method collects a sample containing multiple gas species into a common volume,…

Data Analysis, Statistics and Probability · Physics 2009-11-13 John K. Stockton , Ari K. Tuchman

Novel gaseous detectors of single photons for RICH applications have been developed and installed on COMPASS RICH-1 in 2016. They have a hybrid architecture consisting of two staggered THGEM layers (one equipped with a CsI photoconverting…

The performance of the recently commissioned spectrometer PEAXIS for resonant inelastic soft X-ray scattering (RIXS) and X-ray photoelectron spectroscopy (XPS) and its hosting beamline U41-PEAXIS at the BESSY II synchrotron are…

Instrumentation and Detectors · Physics 2019-06-25 Christian Schulz , Klaus Lieutenant , Jie Xiao , Tommy Hofmann , Deniz Wong , Klaus Habicht

We report the first year on-orbit performance results for the Galaxy Evolution Explorer (GALEX), a NASA Small Explorer that is performing a survey of the sky in two ultraviolet bands. The instrument comprises a 50 cm diameter modified…

We discuss the design and performance of TEXES, the Texas Echelon Cross Echelle Spectrograph. TEXES is a mid-infrared (5-25 um) spectrograph with several operating modes: high-resolution, cross-dispersed with a resolving power of R=100,000,…

Astrophysics · Physics 2009-11-07 J. H. Lacy , M. J. Richter , T. K. Greathouse , D. T. Jaffe , Q. Zhu