Related papers: Development of one-coordinate gaseous detector for…
X-ray absorption fine structure (XAFS) and x-ray emission spectroscopy (XES) are advanced x-ray spectroscopies that impact a wide range of disciplines. However, unlike the majority of other spectroscopic methods, XAFS and XES are…
Recently, a new detector concept, for combined imaging and spectroscopy of fast-neutrons and gamma was presented. It encompasses a liquid-xenon (LXe) converter-scintillator coupled to a UV-sensitive gaseous Thick Gas Electron Multiplier…
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point…
We present our cosmic shear analysis of GEMS, one of the largest wide-field surveys ever undertaken by the Hubble Space Telescope. Imaged with the Advanced Camera for Surveys (ACS), GEMS spans 795 square arcmin in the Chandra Deep Field…
Layered materials (LMs) are at the centre of an ever increasing research effort due to their potential use in a variety of applications. The presence of imperfections, such as bi- or multilayer areas, holes, grain boundaries, isotropic and…
In this work we show the operation and results of an X-ray fluorescence imaging system using a cascade of three gas electron multipliers (GEM) and a pinhole assembly. The detector operates in Ar/CO$_2$ (90/10) at atmospheric pressure, with…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
We have developed a compact Compton gamma-ray imager with a large field of view and a low channel-count that is capable of quickly localizing gamma-ray sources in the few hundred keV - several MeV range. The two detector planes (scatter and…
Ground based extensive air showers arrays can observe GRBs in the 1-1000 GeV energy range using the "single particle" techique. The sensitivity to detect a GRB as a function of the burst parameters and the detector characteristics are…
One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of…
The low repetition rates and possible shot-to-shot variations in laser-plasma studies place a high value on single-shot diagnostics. For example, white-beam scattering methods based on broadband backlighter x-ray sources are used to…
The latest all-sky survey in hard X-ray band was performed by the HEAO-1 satellite (13-80 keV) with an angular resolution of 24x48 arcmin. A diffuse hard X-Ray background (HXB) was detected between 3 and 50 keV. The main scientific goal of…
Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several…
To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital…
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…
Weak gravitational lensing provides a unique method to directly measure the distribution of mass in the universe. Because the distortions induced by lensing in the shape of background galaxies are small, the measurement of weak lensing…
We present a detection scheme for diffusing wave spectroscopy (DWS) based on a two cell geometry that allows efficient ensemble averaging. This is achieved by putting a fast rotating diffuser in the optical path between laser and sample. We…
A breakthrough in the sensitivity level of the hard X-/gamma-ray telescopes, which today are based on detectors that view the sky through (or not) coded masks, is expected when focusing optics will be available also in this energy range.…
The physics basis for an electron-beam based Compton scattering (ECOS) x-ray source is investigated for single-shot experiments at major high energy density facilities such as the Omega Laser Facility, National Ignition Facility, and Z…
Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of…