English
Related papers

Related papers: Optimisation of sample thickness for THz-TDS measu…

200 papers

The $T$-test is probably the most popular statistical test; it is routinely recommended by the textbooks. The applicability of the test relies upon the validity of normal or Student's approximation to the distribution of Student's statistic…

Statistics Theory · Mathematics 2021-01-01 S. Y. Novak

The selection of an optimal photodetector area is closely linked to the attainment of higher data rates in optical wireless communication receivers. If the photodetector area is too large, the channel capacity degrades due to lower…

Signal Processing · Electrical Eng. & Systems 2023-09-19 Muhammad Salman Bashir , Qasim Zeeshan Ahmed , Mohamed-Slim Alouini

An accurate determination of specimen thickness is essential for quantitative analytical electron microscopy. Here we demonstrate that a position-averaged incoherent bright-field signal recorded on an absolute scale can be used to determine…

Materials Science · Physics 2012-09-11 Huolin L. Xin , Ye Zhu , David A. Muller

The superconducting proximity effect is investigated for SN double layers in a regime where the resulting transition temperature T_{c} does not depend on the mean free paths of the films and, within limits, not on the transparency of the…

Mesoscale and Nanoscale Physics · Physics 2009-11-11 M. Zhang , G. Tateishi , G. Bergmann

X-ray reflectometry (XRR) provides researchers and manufacturers with a non-destructive way to determine thickness, roughness, and density of thin films deposited on smooth substrates. Due to the nested nature of equations modeling this…

Materials Science · Physics 2015-06-12 Donald Windover , David L. Gil , Yasushi Azuma , Toshiyuki Fujimoto

We develop a sampling scheme on the sphere that permits accurate computation of the spherical harmonic transform and its inverse for signals band-limited at $L$ using only $L^2$ samples. We obtain the optimal number of samples given by the…

Information Theory · Computer Science 2014-07-25 Zubair Khalid , Rodney A. Kennedy , Jason D. McEwen

We provide a systematic study of the optical models for thin layers: the 3D model, the 2D model and the linearized 2D model. We show that the 2D model is applicable for layers with small optical thicknesses. Excellent agreement of the 2D…

Optics · Physics 2018-01-03 Yilei Li , Tony F. Heinz

A new lower bound on the average reconstruction error variance of multidimensional sampling and reconstruction is presented. It applies to sampling on arbitrary lattices in arbitrary dimensions, assuming a stochastic process with constant,…

Information Theory · Computer Science 2018-06-19 Erik Agrell , Balázs Csébfalvi

Ptychographic reconstructions in reflection geometries are commonly interpreted with the same two-dimensional thin-sample model used in transmission, yet the validity of this approximation has not been established. We develop a…

Optics · Physics 2026-04-08 Sander Senhorst , Stefan Witte , Wim Coene

This paper indicates that the sensitivity and accuracy of an infrared radiometer for emissivity measurements depends not only on its design and the measurement method, but also on the spurious radiation. This spurious radiation must be…

We study superconducting microtraps with rectangular shapes for cold atomic gases. We present a general argument why microtraps open, if brought close to the surface of the superconductor. We show that for a given width of the strips there…

Atomic Physics · Physics 2012-08-21 A. Markowsky , A. Zare , V. Graber , T. Dahm

In this work we have studied the limitations of the TXRF spectroscopy in the upper limit of validity of the technique, when the analyzed specimen ceases to be a thin film. We have evaluated the non-linear effects in spectra obtained from…

Atomic Physics · Physics 2022-08-09 Leonardo Bennun , Maria Natalia Piol , Cristina Vazquez

In semiconductor manufacturing processes, silicon dioxide films are commonly used as barrier layers, insulating layers, and protective layers. Coherence scanning interferometry (CSI) offers thin film thickness measurements with a…

Optics · Physics 2025-03-11 Lixuan Xu , Cheng Chen , Rong Su

Free-space time domain THz spectroscopy accesses electrodynamic responses in a frequency regime ideally matched to interacting condensed matter systems. However, THz spectroscopy is challenging when samples are physically smaller than the…

A method for measuring the transmittivity of optical samples by using squeezed--vacuum radiation is illustrated. A squeezed vacuum field generated by a below--threshold optical parametric oscillator is propagated through a nondispersive…

Quantum Physics · Physics 2009-11-13 V. D'Auria , C. de Lisio , A. Porzio , S. Solimeno , M. G. A. Paris

Single channel measurements play a minor role in today physics, but they are sometimes unavoidable. Comparing to multichannel measurements, there is distribution of measurement time to be chosen in an experiment design. A method to optimize…

Instrumentation and Detectors · Physics 2008-12-03 J. Kaspar , M. Rysavy

For the first time it is shown that for thin metallic films thickness of which not exceed thickness of skin-layer, the problem allows analytical solution for arbitrary boundary value problems. The analysis of dependence of coefficients of…

Mathematical Physics · Physics 2015-05-20 A. V. Latyshev , A. A. Yushkanov

For the accurate representation and reconstruction of band-limited signals on the sphere, an optimal-dimensionality sampling scheme has been recently proposed which requires the optimal number of samples equal to the number of degrees of…

Information Theory · Computer Science 2017-09-11 Wajeeha Nafees , Zubair Khalid , Rodney A. Kennedy , Jason D. McEwen

Spin transport across interfaces is critical for spintronic devices, yet remains difficult to probe on ultrafast timescales. We use terahertz emission spectroscopy on Co|Pt heterostructures whose interface roughness is tuned through the…

We study the effect of a finite sample size, beam divergence and detector thickness on the resolution function of a MIEZE spectrometer. We provide a transparent analytical framework which can be used to determine the optimal trade-off…

Instrumentation and Detectors · Physics 2017-11-23 N. Martin