Related papers: Radiation Hardness Studies in a CCD with High-Spee…
A novel charged particle tracking device, a high precision time projection chamber with gas electron multiplier and pad readout, is a leading candidate as the central tracker for an experiment at the International Linear Collider. To…
CLIC is a proposed linear $e^{+}e^{-}$ collider with center-of-mass energies of up to $3\,\textrm{TeV}$. Its main objectives are precise top quark and Higgs boson measurements, as well as searches for Beyond Standard Model physics. To meet…
We present the two kinds of experimental results. One is a continuous variable dense coding experiment, and the other is a photon number detector with high linearity response, the so called charge integration photon detector (CIPD). They…
The ion beam-induced charge (IBIC) analysis of a commercial silicon photodiode configured as a Position Sensitive Detector (PSD) for energetic charged particles is the subject of this report. Although the photodiode is designed for…
New generation Cadmium Telluride (CZT & CdTe) solid state detectors can provide high quantum efficiency with reasonably good energy resolution and can operate at near room temperature; an unique advantage for space experiments. We present…
A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…
The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…
Metallic microcalorimeters (MMCs) are cryogenic single-particle detectors that rely on a calorimetric detection principle. Due to their excellent energy resolution, close-to-ideal linear detector response, fast signal rise time and the…
The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause…
Swept Charge Devices (SCD) are novel X-ray detectors optimized for improved spectral performance without any demand for active cooling. The Chandrayaan-1 X-ray Spectrometer (C1XS) experiment onboard the Chandrayaan-1 spacecraft used an…
Silicon carbide (SiC) has been widely adopted in the semiconductor industry, particularly in power electronics, because of its high temperature stability, high breakdown field, and fast switching speeds. Its wide band gap makes it an…
Due to the increased commercial availability, wide-bandgap semiconductors and their radiation hardness have recently received increased interest from the particle physics community. 4H-Silicon Carbide (SiC), especially, is an attractive…
The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a…
The physics program of future lepton colliders such as the ILC, will benefit from a jet energy resolution in the range 3-4%. The International Large Detector (ILD) reaches this goal over a large range of jet energies. In this paper, we…
Together with the recent CLIC detector model CLICdet a new software suite was introduced for the simulation and reconstruction of events in this detector. This note gives a brief introduction to CLICdet and describes the CLIC experimental…
Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy…
The CLIC study of a high-energy (0.5 - 5 TeV), high-luminosity (1034 - 1035 cm-2 sec-1) e+e- linear collider is presented. Beam acceleration using high frequency (30 GHz) normal-conducting structures operating at high accelerating fields…
The International Linear Collider (ILC) is a proposed electron-positron collider with a center-of-mass energy of 500~GeV, and a peak luminosity of $2 \cdot 10^{34}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$. The ILC will complement the Large Hadron…
The Electron-ion collider in China (EicC) is a proposed future electron-ion collider designed to achieve a high luminosity, with a center-of-mass energy ranging from 15 to 20 GeV. Excellent particle identification (PID) with extensive…
A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…