Related papers: Scintillation light produced by low-energy beams o…
We performed a time-resolved spectroscopic study of the VUV/UV argon scintillation as a function of pressure and electric field, by means of a wavelength sensitive detector operated with different radioactive sources. Our work conveys new…
The generation of low-emittance electron beams has received significant interest in recent years. Driven by the requirements of X-ray free electron lasers, the emittance of photocathode injectors has been reduced significantly, with a…
Plastic scintillator detectors have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. On the other hand, several articles have reported undesired response dependencies on beam…
The performance of a scintillating fiber detector prototype for tracking under high rate conditions is investigated. A spatial resolution of about100 micron is aimed for the detector. Further demands are low occupancy and radiation hardness…
We introduce a simulation framework for the transport of high and low energy electrons in xenon-based gaseous optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule)…
Liquid argon is used as active medium in a variety of neutrino and Dark Matter experiments thanks to its excellent properties of charge yield and transport and as a scintillator. Liquid argon scintillation photons are emitted in a narrow…
At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee…
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of…
Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular…
The CMS detector at the LHC requires a major upgrade to cope with the higher instantaneous luminosity and the elevated radiation levels. The active media of the forward backing hadron calorimeters is projected to be radiation-hard, high…
The results of the analysis of solid-state track detectors CR39 and nuclear photoemulsion plates irradiated in beams of accelerated xenon ions with energies of 3.2 MeV/n and 3.8 GeV/n at the NICA accelerator complex are presented.
The HERMES (High Energy Rapid Modular Ensemble of Satellites) Pathfinder mission aims to develop a constellation of nanosatellites to study astronomical transient sources, such as gamma-ray bursts, in the X and soft $\gamma$ energy range,…
Advanced particle acceleration methods have produced high-peak-current ion beams with broad energy spread and complex spatial distribution. There is an urgent need to develop online spatial-resolved energy spectrometers for high-energy…
Fast emitting polymeric scintillators are requested in advanced applications where high-speed detectors with large signal-to-noise ratio are needed. However, their low density implies a weak stopping power of high energy radiations, thus a…
We present the first application of polysiloxane-based scintillators as active medium in a shashlik sampling calorimeter. These results were obtained from a testbeam campaign of a $\sim$6$\times$6$\times$45 cm$^3$ (13 $X_0$ depth)…
Plastic scintillators are a versatile and inexpensive option for particle detection, which is why the largest particle physics experiments, CMS and ATLAS, use them extensively in their calorimeters. One of their challenging aspects,…
This article describes the crystal selection and quality control utilized to develop and calibrate a high resolution array of CsI(TI) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the…
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX…
A novel beam profiler based on microstructured scintillation resin is presented. The detector consists of a bundle of waveguides, with an active area of 30 x 30 mm$^2$ and a pitch of 400 $\mu$m, obtained by molding a scintillating resin…