English
Related papers

Related papers: An Improved Shashlyk Calorimeter

200 papers

A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the…

Instrumentation and Detectors · Physics 2009-11-10 G. S. Atoian , V. V. Issakov , O. V. Karavichev , T. L. Karavicheva , A. A. Poblaguev , M. E. Zeller

An iron- plastic-scintillator shashlik calorimeter with a 4.3 $X_0$ longitudinal segmentation was tested in November 2016 at the CERN East Area facility with charged particles up to 5 GeV. The performance of this detector in terms of…

A simulation study of energy resolution, position resolution, and $\pi^0$-$\gamma$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the…

Instrumentation and Detectors · Physics 2017-08-02 Ashim Roy , Shilpi Jain , Sunanda Banerjee , Satyaki Bhattacharya , Gobinda Majumder

A spaghetti calorimeter (SPACAL) prototype with scintillating crystal fibres was assembled and tested with electron beams of energy from 1 to 5 GeV. The prototype comprised radiation-hard Cerium-doped Gd$_3$Al$_2$Ga$_3$O$_{12}$ (GAGG:Ce)…

The fine-sampling electromagnetic calorimeter prototype has been experimentally tested using the 1-19 GeV/c tagged beams of negatively charged particles at the U70 accelerator at IHEP, Protvino. The energy resolution measured by electrons…

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A $4\times4$ array of final design modules showed an energy resolution of about 11%…

Instrumentation and Detectors · Physics 2012-08-27 The ALICE EMCal group

A novel technique for longitudinal segmentation of shashlik calorimeters has been tested in the CERN West Area beam facility. A 25 tower very fine samplings e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8…

The electromagnetic calorimeter (ECAL) is a key detector component for precise electron and photon measurements in electron-ion collision experiments. At the Electron-Ion Collider in China (EicC), high-performance calorimetry is essential…

Instrumentation and Detectors · Physics 2026-03-23 Ye Tian , Souvik Maity , Jingyu Li , Yuancai Wu , Shan Sha , Yutie Liang , Aiqiang Guo , Yuxiang Zhao , Dexu Lin

A Shashlyk-type electromagnetic calorimeter (ECal) will be used in the Multi-purpose Detector at Nuclotron-based Ion Collider facility to study the properties of nuclear matter. In this experiment, the ECal detector is responsible for…

Instrumentation and Detectors · Physics 2019-10-15 Fuyue Wang , Yi Wang , Dong Han

We describe the results of detailed 3-D Monte Carlo simulations of a "CZT calorimeter" that can be used to detect photons in the keV to several MeV range. Several astrophysics applications require the detection of photons in the energy…

Astrophysics · Physics 2009-11-11 I. Jung , H. Krawczynski , S. Komarov , L. Sobotka

We report on the simulation results for the angular resolution of an electromagnetic (EM) sampling calorimeter with photons in the range of 100~MeV to 2~GeV. The simulation model of the EM calorimeter consists of alternating layers of a…

Instrumentation and Detectors · Physics 2023-04-26 Junlee Kim , Eun-Joo Kim , YoungJun Kim , JungKeun Ahn , GeiYoub Lim

The development prospects have been considered of a scintillator-photodiode type detector with improved energy resolution attaining several per cent ($R=1-2%$). The main contributions to the scintielectron detector energy resolution have…

High Energy Physics - Experiment · Physics 2007-05-23 S. V. Naydenov , V. D. Ryzhikov

A novel type of calorimeter based on grains of inorganic scintillating crystal readout by wave length shifting fibers is proposed. The concept and main features as well as the prototype design are introduced and the first results obtained…

We present the results of a test beam campaign on a capillary-tube fibre-based dual-readout calorimeter, designed for precise hadronic and electromagnetic energy measurements in future collider experiments. The calorimeter prototype…

The electromagnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with high resolution. The current status of the calorimeter, now in its seventh year…

Instrumentation and Detectors · Physics 2019-08-14 Johannes M. Bauer

The development prospects of a scintillator-photodiode type detector with an improved energy resolution attaining few per cent, R from 1 to 2%, are considered. The main resolution components have been analyzed theoretically, their…

Instrumentation and Detectors · Physics 2007-05-23 S. V. Naydenov , V. D. Ryzhikov

Calibration of the three layer NaI(Tl) spherical calorimeter of the SND detector using electron -- positron scattering events is described. Energy resolution of $5 % (FWHM/2.36)$ for 500 MeV photons was achieved.

Instrumentation and Detectors · Physics 2009-10-31 M. N. Achasov , D. A. Bukin , T. V. Dimova , V. P. Druzhinin , V. B. Golubev , V. N. Ivanchenko , A. A. Korol

The CALICE prototype for a Si/W electromagnetic calorimeter has been tested in large scale test beams. Several million events with electrons and hadrons of different energies and impact angles have been recorded. The energy resolution has…

Instrumentation and Detectors · Physics 2009-02-19 Marcel Reinhard

The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to…

Instrumentation and Detectors · Physics 2012-09-28 CALICE Collaboration , C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , T. Buanes , G. Eigen , Y. Mikami , N. K. Watson , T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward , W. Yan , D. Benchekroun , A. Hoummada , Y. Khoulaki , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , G. Falley , K. Gadow , P. Göttlicher , C. Günter , B. Hermberg , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Feege , E. Garutti , I. Marchesini , M. Ramilli , P. Eckert , T. Harion , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , P. D. Dauncey , A. -M. Magnan , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , N. Kirikova , V. Kozlov , P. Smirnov , Y. Soloviev , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , C. Kiesling , S. Pfau , K. Seidel , F. Simon , C. Soldner , M. Szalay , M. Tesar , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , T. Takeshita , S. Uozumi , J. Sauer , S. Weber , C. Zeitnitz
‹ Prev 1 2 3 10 Next ›