Related papers: Overview and Status of the CMS Silicon Strip Track…
The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 "telescopes", with eight…
A new downstream tracking system, known as the Mighty Tracker, is planned to be installed at LHCb during LS4 of the LHC. This will allow an increase in instantaneous luminosity from $2\cdot10^{33}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ to…
The CMS experiment at CERN has released research-quality data from particle collisions at the LHC since 2014. Almost all data from the first LHC run in 2010-2012 with the corresponding simulated samples are now in the public domain, and…
A central tracker based on silicon microstrip sensors has been envisaged for the e+e- linear collider experiments. A full simulation program based on GEANT4 has been developed to study performance of the tracker. We report some preliminary…
The entire CMS silicon pixel detector will be replaced to operate at the High-Luminosity LHC. In this contribution, the new Tracker Endcap Pixel detector will be presented, focusing on a novel concept to provide both power and data…
CLIC is a proposed linear $e^+e^-$ collider with center-of-mass energies of up to 3 TeV. Its main objectives are precise top quark, Higgs boson and Beyond Standard Model physics. In addition to spatial resolutions of a few micrometers and a…
The physics aims at the proposed high-energy $e^+e^-$ collider CLIC pose challenging demands on the performance of the detector system. Precise hit-time tagging, an excellent spatial resolutions, and a low mass are required for the vertex…
For the barrel part of the CMS pixel tracker about 800 silicon pixel detector modules are required. The modules are bump bonded, assembled and tested at the Paul Scherrer Institute. This article describes the experience acquired during the…
The LHCb detector will be upgraded during the Long Shutdown 2 (LS2) of the LHC in order to cope with higher instantaneous luminosities and to read out the data at 40 MHz using a trigger-less readout system. The current LHCb main tracking…
The High Luminosity LHC phase includes an upgrade to the muon stations for the CMS Experiment. CMS trigger and muon identification performance will be crucial, and it is, therefore, necessary to install new GEM stations to extend acceptance…
Precision timing has alway been a prominent topic in the instrumentation for high-energy physics experiments. In this document I discuss what the perspectives are for the use of silicon sensors for a time-of-flight detector in a…
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6*10^34 cm^-2 s^-1. A consequence of this increased luminosity is the expected radiation…
The High-Luminosity Large Hadron Collider (HL-LHC) is designed to achieve higher instantaneous luminosities, enabling the exploration of the rarest processes of the Standard Model (SM). The CMS collaboration has published an Expression of…
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of…
In June 2008 single-sided silicon strip sensors with 50 $\mu$m readout pitch were tested in a highly energetic pion beam at the SPS at CERN. The purpose of the test was to evaluate characteristic detector properties by varying the strip…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
4-dimensional (4D) trackers with ultra fast timing (10-30 ps) and very fine spatial resolution (O(few $\mu$m)) represent a new avenue in the development of silicon trackers, enabling new physics capabilities beyond the reach of the existing…
The CMS experiment is a multi-purpose detector successfully operated at the LHC where predominantly pp collisions take place at various centre of mass energies up to sqrt(s)=8 TeV at present. Discussed are pp collision results until end of…
Since the end of Run 1 of the LHC in 2012, the outermost ring has been added to the CMS Cathode Strip Chambers (CSC) endcap muon detector, and the readout electronics of the innermost ring of CSCs have been upgraded to accommodate the…
At the High Luminosity LHC (HL-LHC), the CMS experiment will face a harsh environment with a high instantaneous luminosity up to 7x10$^{34}$/cm$^2$/s corresponding to an average of 140-200 multiple proton-proton collisions per bunch…