English
Related papers

Related papers: Realization and application of a 111 million pixel…

200 papers

In this paper we describe the design, construction, and operation of a first large area double-phase liquid argon Large Electron Multiplier Time Projection Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the…

A silicon 3D detector with a single cell of 50x50 um2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated electronics used also for determining time…

Instrumentation and Detectors · Physics 2019-06-26 G. Kramberger , V. Cindro , D. Flores , S. Hidalgo , B. Hiti , M. Manna , I. Mandić , M. Mikuž , D. Quirion , G. Pellegrini , M. Zavrtanik

A micro-pulse lidar at eye-safe wavelength is constructed based on an up-conversion single-photon detector. The ultralow noise detector enables using integration technique to improve the signal-to-noise ratio of the atmospheric…

We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates…

The Starshot Breakthrough Initiative aims to send one-gram microchip probes to Alpha Centauri within 20 years, using gram-scale lightsails propelled by laser-based radiation pressure, reaching velocities nearing a fifth of light speed. This…

Deep optical and near-infrared imaging of the entire Galactic plane is essential for understanding our Galaxy's stars, gas, and dust. The second data release of the DECam Plane Survey (DECaPS2) extends the five-band optical and…

The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background…

An X-ray detector based on the combination of an integrated Micromegas stage with a pixel chip has been built in order to be installed at the CERN Axion Solar Telescope. Due to its high granularity and spatial resolution this detector…

Instrumentation and Detectors · Physics 2014-10-02 Christoph Krieger , Klaus Desch , Jochen Kaminski , Michael Lupberger , Theodoros Vafeiadis

We describe the deployment and first tests on Sky of CONCERTO, a large field-of-view (18.6arc-min) spectral-imaging instrument. The instrument operates in the range 130-310GHz from the APEX 12-meters telescope located at 5100m a.s.l. on the…

The quantum efficiency and reflectivity of thick, back-illuminated CCD's being fabricated at LBNL for astronomical applications are modeled and compared with experiment. The treatment differs from standard thin-film optics in that (a)…

Applied Physics · Physics 2017-09-13 D. E. Groom , S. Haque , S. E. Holland , W. F. Kolbe

The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective…

Astrophysics · Physics 2009-11-11 Hua Feng , Philip Kaaret , Hans Andersson

The Large Hadron Collider (LHC) at CERN will undergo an upgrade in order to increase its luminosity to $7.5 \times 10^{34}$ cm$^{-2}$s$^{-1}$. The increased luminosity during this High-Luminosity running phase (HL-LHC), starting around…

Instrumentation and Detectors · Physics 2023-09-04 The Tracker Group of the CMS Collaboration

Thin planar pixel modules are promising candidates to instrument the inner layers of the new ATLAS pixel detector for HL-LHC, thanks to the reduced contribution to the material budget and their high charge collection efficiency after…

Instrumentation and Detectors · Physics 2016-09-21 Anna Macchiolo , Richard Nisius , Natascha Savic , Stefano Terzo

We have used the STACEE high-energy gamma-ray detector to look for fast blue-green laser pulses from the vicinity of 187 stars. The STACEE detector offers unprecedented light-collecting capability for the detection of nanosecond pulses from…

We have developed a new capacitive transimpedance amplifier (CTIA) that can be operated at 2 K, and have good performance as readout circuits of astronomical far-infrared array detectors. The circuit design of the present CTIA consists of…

The STAR Silicon Strip Detector (SSD) completes the three layers of the Silicon Vertex Tracker (SVT) to make an inner tracking system located inside the Time Projection Chamber (TPC). This additional fourth layer provides two dimensional…

We present the architecture, design and first test results of SPIDER, the first prototype of a TSMC CMOS 65 nm ASIC designed for the time measurement path of LHCb Electromagnetic Calorimeter after LS4 Upgrade. The main requirements for the…

Laser cutting of semiconductor wafers and transparent dielectrics has become a dominant process in manufacturing industries, encompassing a wide range of applications from flat display panels to microelectronic chips. Limited by the…